500L Low-Temperature Incubator 0.1°C -40-65°C ATOMFAIR®

$9,500.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

500 L low-temperature incubator with -40-65°C range, 0.1°C resolution, ±0.5/±1.0°C fluctuation, 3 shelves, and AC380V 50Hz power. Order now.

500L Low-Temperature Incubator, -40-65℃ Temperature Control Range
Research-grade laboratory product
Product Overview

500L Low-Temperature Incubator, -40-65℃ Temperature Control Range is designed for low-temperature cultivation, near-ambient incubation, sample preservation, stability testing, and temperature-controlled holding. With a nominal capacity of 500 L and a temperature range of -40-65℃, it supports controlled handling of cultures, fungal samples, microorganisms, preserved materials, and other laboratory test loads.

The cabinet layout is defined by the chamber size is 800×700×900mm, overall dimensions are 1000×1210×1980mm, the standard shelf setup is 3 shelves, input power is 7100 W, the power supply is AC380V 50Hz. These dimensions and electrical requirements help laboratories plan bench-side placement, floor-standing installation, teaching use, quality inspection, research sample staging, and repeated daily workflows.

Temperature performance includes 0.1°C temperature resolution, high temp ±0.5°C; low temp ±1.0°C fluctuation control, a timer range of 0 to 5999 min. The working chamber uses Mirror stainless-steel inner chamber with rounded-corner transitions and removable or adjustable shelf supports for easier cleaning and loading. Cooling configurations use a compressor and circulation fan with an environmentally oriented refrigerant and airflow circulation system. This construction supports regular loading, cleaning, observation, and repeated operation where stable environmental conditions are important.

Control options are shown as AF-LI500-CB40: Microcomputer liquid-crystal temperature controller. Optional functions may include an embedded printer, RS485 communication, USB data transfer, independent over-temperature alarm protection, multi-segment programmable control, and UV sterilization for applicable mold configurations. Accessory availability and custom chamber-size requirements can be checked by e-mail before ordering.

Product Specifications
Parameter Specification
Product Type Low-Temperature Incubator
Nominal Capacity 500 L
Atomfair Models AF-LI500-CB40
Temperature Range -40-65℃
Temperature Resolution 0.1°C
Temperature Fluctuation high temp ±0.5°C; low temp ±1.0°C
Input Power 7100 W
Power Supply AC380V 50Hz
Ambient Temperature +5 to 35°C
Chamber Size 800×700×900mm
Overall Dimensions 1000×1210×1980mm
Shelves 3 shelves
Timer 0 to 5999 min
Inner Chamber and Insulation Mirror stainless-steel inner chamber with rounded-corner transitions and removable or adjustable shelf supports for easier cleaning and loading. Cooling configurations use a compressor and circulation fan with an environmentally oriented refrigerant and airflow circulation system.
Controller Configuration AF-LI500-CB40: Microcomputer liquid-crystal temperature controller
Optional Accessories Optional embedded printer or RS485 communication interface for recording temperature changes; USB data transfer for selected configurations; Independent over-temperature alarm system where supported; Multi-segment programmable controller for selected control configurations. Some accessories may be non-stock and require lead time; email for availability and quotation.
Key Points and Advantages
  • 0.1°C temperature resolution supports finer setpoint adjustment, which is helpful for routine cultivation, preservation, and method repeatability.
  • The published fluctuation level of high temp ±0.5°C; low temp ±1.0°C helps users maintain steadier chamber conditions during day-to-day experimental cycles.
  • Sub-ambient temperature options extend the usable application range into preservation, low-temperature incubation, and stability tasks that ordinary incubators may not cover.
  • The published shelf configurations help laboratories organize flasks, bottles, trays, and routine test loads more flexibly within the available chamber volume.
  • Optional accessories can include embedded printers, RS485 communication, USB data transfer, independent over-temperature alarm support, multi-segment programmable control, and mold-series UV sterilization where applicable.
  • If a configuration needs a different chamber size or accessory package, the quotation can be adjusted by e-mail before order confirmation.
APPLICATION SCOPE: Suitable for low-temperature cultivation, near-ambient incubation, sample preservation, stability testing, and holding tasks that require cooling capability beyond a standard constant-temperature incubator.
PACKAGING: The equipment is prepared with protective inner cushioning, reinforced outer packaging, and transport-oriented structural support to help reduce vibration and handling impact during storage and delivery. Export reinforcement or other packing adjustments can be discussed when project quantity, route, or receiving conditions require it.
IMPORTANT NOTICE: Please confirm the exact configuration, installation footprint, power supply, accessory package, and delivery arrangement before ordering. If a custom chamber size is required, please contact us by e-mail for quotation and availability review.
LABORATORY PROCUREMENT SUPPORT
For model selection, specification comparison, accessory review, or quotation support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

Manufacturer: Atomfair LLC

Brand: ATOMFAIR®

Operate the incubator only within the specified ambient temperature range of +5 to 35°C and connect it to a dedicated AC380V 50Hz power supply rated for at least 7100W. The unit must be placed on a level surface with adequate space for the overall dimensions (1000×1210×1980mm) and with the optional over-temperature alarm system installed for safety.

  • Ambient Temperature Constraint: The incubator must be operated in an ambient temperature of +5 to 35°C to maintain proper cooling and performance.
  • Power Supply Constraint: The unit requires a dedicated AC380V 50Hz power supply with a minimum input power of 7100W.
  • Installation Space Constraint: Install the incubator on a level floor with sufficient clearance for the overall dimensions of 1000×1210×1980mm.
  • Over-Temperature Alarm Safety: If equipped, the independent over-temperature alarm system must be tested before use to ensure safe operation.
  • Chamber Cleaning Constraint: The inner chamber features rounded corners and removable shelf supports for easier cleaning; maintain regular cleaning to prevent contamination.

This guide provides steps for safely installing and initializing the low-temperature incubator. Follow these steps to ensure proper operation and avoid electrical or environmental hazards.

Required Equipment:

  1. Confirm Configuration
    Confirm the installation footprint, power supply specifications, and accessory package with the supplier before ordering.
  2. Place the Incubator
    Place the incubator on a level, stable surface within an ambient temperature range of +5 to 35°C.
  3. Connect Power Supply
    Connect the unit to a dedicated AC380V 50Hz power supply and verify the power rating meets the 7100W requirement.
  4. Set Control Parameters
    Set the desired temperature and timer using the microcomputer liquid-crystal controller.

Why does the temperature fluctuation differ between high and low temperature ranges (±0.5°C vs ±1.0°C) on the Atomfair 500L low-temperature incubator?

The fluctuation specification reflects the inherent challenge of maintaining stability at sub-ambient temperatures due to compressor cycling and heat exchange dynamics. At low temperatures (-40°C to near ambient), the compressor must work harder and cycle more frequently, resulting in ±1.0°C fluctuation, while at high temperatures (ambient to 65°C), heating control achieves ±0.5°C. This is stated in the product specifications.

What are the electrical and environmental installation requirements for the Atomfair 500L low-temperature incubator?

The incubator requires a AC380V 50Hz power supply with 7100W input power, and must be operated in an ambient temperature range of +5 to 35°C. The overall dimensions are 1000×1210×1980mm, requiring adequate floor space and clearance for ventilation. Optional accessories like RS485 or USB data transfer may require additional integration planning.

What safety and monitoring features are available for the Atomfair 500L low-temperature incubator to protect samples during long-term operation?

The incubator offers an optional independent over-temperature alarm system that provides separate protection beyond the main controller. Additionally, optional embedded printer, RS485 communication, and USB data transfer allow continuous temperature recording. The mirror stainless-steel inner chamber with rounded corners facilitates cleaning and reduces contamination risk.

The 500L Low-Temperature Incubator (AF-LE-E-LTIN-0500-5CB5) delivers a -40 to 65°C operating range with 0.1°C resolution and ±0.5°C (high temp) / ±1.0°C (low temp) fluctuation, making it suitable for sub-ambient cultivation, preservation, and stability testing, though the 7100 W input power and AC380V 50Hz requirement necessitate dedicated electrical infrastructure.

Positive

  • Sub-ambient temperature range: The -40 to 65°C range extends capability beyond standard incubators, enabling low-temperature cultivation, sample preservation, and stability tasks that require cooling below ambient.
  • High temperature resolution and control: With 0.1°C resolution and ±0.5°C fluctuation at high temperatures, the unit supports fine setpoint adjustments and repeatable incubation conditions for routine laboratory workflows.

Trade-offs

  • High electrical infrastructure demand: The 7100 W input power and AC380V 50Hz power supply require dedicated three-phase electrical service, which may necessitate facility upgrades or restrict placement in laboratories without compatible wiring.
  • Elevated low-temperature fluctuation: Temperature fluctuation at low temperatures is ±1.0°C, which may limit suitability for applications requiring tighter thermal stability below ambient, such as sensitive preservation or kinetic studies.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).