460L General Biochemical Incubator with 5-70°C Temperature Control Range
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, capacity matching, power supply confirmation or configuration review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
When the set temperature is below 10°C, ambient temperature must be below 26°C to maintain stable operation. The unit requires AC 220 V, 50 Hz power supply and should be placed in a clean, well-ventilated laboratory environment.
- Ambient Temperature Constraint: Ambient temperature must be below 26°C when the set temperature is below 10°C to prevent compressor overload or temperature drift.
- Power Supply Requirement: The incubator requires a dedicated AC 220 V, 50 Hz power supply with adequate grounding to ensure safe and reliable operation.
- Over-Temperature Limit Protection: The built-in over-temperature limit support automatically interrupts heating if the chamber exceeds safe thresholds, reducing risk of sample damage or fire.
- Power-Failure Memory: The power-failure memory function retains set parameters after an unexpected power loss, preventing data loss and operational disruption.
Position the incubator on a level, stable surface with adequate clearance for ventilation and door swing. Connect to a grounded AC 220 V, 50 Hz outlet and allow the chamber to stabilize at ambient temperature before setting the desired temperature.
Required Equipment: Grounded AC 220 V, 50 Hz power outlet, Level surface with ventilation clearance
- Position the incubator
Place the incubator on a level, stable surface with at least 10 cm clearance on all sides for proper air circulation and door operation. - Connect power supply
Plug the power cord into a dedicated, grounded AC 220 V, 50 Hz outlet and verify that the LCD display illuminates. - Set the desired temperature
Use the microcomputer control panel to input the target temperature within the 5–70°C range and confirm the set value on the LCD display. - Verify ambient temperature for low set points
If the set temperature is below 10°C, confirm that the ambient temperature is below 26°C to ensure stable cooling performance. - Load samples into the chamber
Arrange culture containers or samples on the stainless-steel shelves, ensuring adequate spacing for uniform air circulation. - Close the door securely
Seal the magnetic door fully and verify that the inner door is closed to minimize temperature disturbance during operation. - Set the timer for scheduled operation
Program the built-in timer from 0 to 9999 minutes as needed for automated incubation cycles and reduce manual supervision.
How does the 460L biochemical incubator maintain temperature uniformity across the chamber at different set points?
The incubator uses PID temperature control combined with a circulation fan and air-duct structure to improve temperature uniformity, specified as ±2°C across the 460L chamber. The stainless-steel interior and magnetic door seal also help reduce heat loss and maintain consistent conditions.
What ambient temperature conditions are required when operating the incubator below 10°C?
When the set temperature is below 10°C, the ambient temperature must be below 26°C to ensure proper operation. This is a critical installation constraint for low-temperature applications such as BOD testing or microorganism preservation.
What are the power and installation requirements for the 460L biochemical incubator?
The incubator requires AC 220V, 50Hz power supply with a rated power of 1000W. It has overall dimensions of 885 x 805 x 1795 mm and a net weight of 150 kg, so it requires a floor-standing location with adequate space and floor loading capacity. The unit includes a magnetic door seal and inner observation door to minimize disturbance during use.