35 L Electric Heated Incubator LCD 65 °C Lab ATOMFAIR®

$800.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

35 L LCD electric heated incubator with 200 W power, RT + 5 to 65 °C control, 0.1 °C resolution, and 340 × 320 × 320 mm chamber for culture work. Order now.

SKU: AF-LE-E-EHIN-0035-032B
Category:
Brands:

35 L LCD Controller Electric Heated Constant Temperature Incubator
Research-grade laboratory product
Product Overview

35 L LCD Controller Electric Heated Constant Temperature Incubator is designed for routine constant temperature incubation, culture work, sample holding, and general laboratory heating workflows. Electric heating, forced convection airflow, glass observation door, and optional programmable control for routine incubation work. The configuration provides RT + 5 to 65 °C, 200 W rated power, a working chamber of 340 × 320 × 320 mm (W × D × H), and external dimensions of 620 × 490 × 490 mm (W × D × H).

The control and chamber design support practical laboratory operation: Standard controller or LCD controller in B variants. laboratory chamber construction

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include LCD or programmable controller; printer; U-disk data storage; RS485 interface and communication software; UV sterilization; independent over-temperature controller.

This equipment is suited to laboratories that need routine constant temperature incubation, culture work, sample holding, and general laboratory heating workflows, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-EHIN-035B
Product Family Electric Heated Constant Temperature Incubator
Configuration 35 L LCD Controller
Rated Operating Power 200 W
Working Chamber Size 340 × 320 × 320 mm (W × D × H)
Overall Dimensions 620 × 490 × 490 mm (W × D × H)
Model Configuration LCD controller
Temperature Control Range RT + 5 to 65 °C
Temperature Resolution / Fluctuation 0.1 °C / ±0.5 °C
Working Ambient Temperature +5 to +35 °C
Power Supply AC 220 V, 50 Hz
Controller Options Standard controller or LCD controller in B variants
Airflow Forced convection with adjustable circulation fan
Sterilization Optional UV sterilization
Optional Accessories and Functions LCD or programmable controller; printer; U-disk data storage; RS485 interface and communication software; UV sterilization; independent over-temperature controller
Performance Features
  • This product family uses electric heating and a forced convection airflow system to improve temperature response and chamber uniformity. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • A glass inner door or observation window supports chamber viewing during incubation work. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • Optional programmable control supports multi-step temperature and time programming for selected configurations. This allows the configuration to match documentation, communication and monitoring needs in routine constant temperature incubation, culture work, sample holding, and general laboratory heating workflows.
  • Optional printer, U-disk export, communication interface, and UV sterilization are listed for this family. This supports chamber hygiene and contamination-control routines for routine constant temperature incubation, culture work, sample holding, and general laboratory heating workflows.
  • Independent over-temperature protection is available as an option in the source accessory list. This supports controlled, repeatable operation for routine constant temperature incubation, culture work, sample holding, and general laboratory heating workflows.
  • Higher-capacity vertical models use larger cabinet formats with three or four standard shelves. This supports controlled, repeatable operation for routine constant temperature incubation, culture work, sample holding, and general laboratory heating workflows.
APPLICATION SCOPE: Suitable for routine constant temperature incubation, culture work, sample holding, and general laboratory heating workflows in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 620 × 490 × 490 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: LCD or programmable controller; printer; U-disk data storage; RS485 interface and communication software; UV sterilization; independent over-temperature controller. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator must be operated within the specified ambient temperature range of +5 to +35°C and requires a stable AC 220 V 50 Hz power supply. Without the optional independent over-temperature controller, the unit lacks automatic over-temperature protection and must be monitored during operation.

  • Power Supply: The incubator requires a dedicated AC 220 V 50 Hz power supply with proper grounding.
  • Ambient Temperature: Operate the incubator only in ambient temperatures between +5 and +35°C to ensure proper temperature control.
  • Over-Temperature Protection: Install the optional independent over-temperature controller if automatic over-temperature shutdown is required.
  • Transport Orientation: Keep the packed incubator upright during transport and use suitable lifting equipment to avoid impact damage.
  • Installation Space: Provide sufficient clearance around the incubator for ventilation and access to the 620 × 490 × 490 mm external dimensions.

This procedure describes the initial installation and setup of the 35 L incubator. It covers site verification, power connection, and chamber preparation.

Required Equipment: Lifting equipment

  1. Verify Installation Space
    Confirm that the installation site provides adequate space for the 620 × 490 × 490 mm external dimensions and access to a grounded AC 220 V 50 Hz power outlet.
  2. Connect Power Supply
    Connect the incubator to a dedicated AC 220 V 50 Hz power supply with proper grounding.
  3. Prepare Chamber for Operation
    Ensure that the chamber interior, shelves, sensors, and control interfaces are unobstructed and accessible for cleaning and inspection.

What is the advantage of the optional programmable controller for multi-step incubation protocols in the 35 L LCD incubator?

The optional programmable controller enables multi-step temperature and time programming, allowing automated incubation workflows for routine culture work, sample holding, and general laboratory heating. This is a configurable option for the Atomfair AF-EHIN-035B model, as stated in the technical specifications and performance features.

Can the 35 L LCD incubator be integrated with external data logging or monitoring systems?

Yes, the incubator supports optional RS485 interface and communication software, as well as printer and U-disk data storage. These accessories allow integration with external data logging and monitoring systems for documentation and communication, as listed in the optional functions for the 35 L LCD controller configuration.

What are the installation requirements and safety features of the 35 L LCD constant temperature incubator?

Installation requires a space matching the external dimensions of 620 × 490 × 490 mm and an AC 220 V, 50 Hz power supply. Safety features include an optional independent over-temperature controller for protection against overheating, and a glass observation door that allows chamber viewing without disturbing the internal environment.

The 35 L LCD Controller Electric Heated Constant Temperature Incubator (AF-EHIN-035B) uses forced convection airflow and electric heating for uniform temperature distribution from RT+5 to 65°C, with a resolution of 0.1°C and fluctuation of ±0.5°C. It requires a working ambient temperature range of +5 to +35°C and offers optional independent over-temperature protection for controlled operation.

Positive

  • Forced convection airflow: The forced convection system with adjustable circulation fan improves temperature response and chamber uniformity, supporting consistent incubation conditions.
  • Optional over-temperature protection: An independent over-temperature controller is available as an optional accessory, adding a safety layer for protecting samples and equipment during unattended operation.

Trade-offs

  • Limited temperature range: The incubator operates only from RT+5 to 65°C, making it unsuitable for high-temperature or sterilization applications requiring temperatures above 65°C.
  • Narrow ambient temperature requirement: The specified working ambient temperature is +5 to +35°C, restricting placement to climate-controlled laboratory environments and precluding use in unconditioned spaces.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).