30L General Biochemical Incubator 0-50°C LCD ATOMFAIR®

$850.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

30 L biochemical incubator with 0-50°C PID control, ±1°C accuracy, 260 × 350 × 350 mm stainless chamber, LCD timer and 500 W power. Order now.

30L General Biochemical Incubator with 0-50°C Temperature Control Range
Research-grade laboratory product
Product Overview

30L General Biochemical Incubator with 0-50°C Temperature Control Range is designed for microbiology culture work, sample holding, routine incubation and steady low-temperature laboratory processing where clear control and stable cabinet conditions matter in daily use.

This 30 L model combines microcomputer temperature control, an LCD display, a stainless-steel working chamber, removable shelves and a magnetic door seal in a clean cabinet structure that supports repeatable operation and convenient observation during laboratory workflows.

The chamber size is 260 x 350 x 350 mm, the external size is 500 x 520 x 965 mm, and the rated power is 500 W. The 0-50 C temperature control range supports bacteria and mold culture, microorganism preservation, water analysis, BOD-related work, plant cultivation and other temperature-managed laboratory tasks described for this product family.

The cabinet is intended for research institutes, university laboratories, public health work, pharmaceutical inspection, environmental analysis and other technical settings that need a practical incubator with straightforward daily operation, visible status display and an interior layout that is easy to organize and clean.

When the set temperature is below 10 C, ambient temperature should be below 26 C.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-BI30-T50
Nominal Capacity 30 L
Effective Capacity 30 L
Temperature Control Range 0 to 50 C
Temperature Control Accuracy +/-1 C
Temperature Uniformity +/-2 C
Display Mode LCD display
Timing Range 0 to 9999 min
Power Supply AC 220 V, 50 Hz
Rated Power 500 W
Working Chamber Size 260 x 350 x 350 mm
Overall Dimensions 500 x 520 x 965 mm
Net Weight 45 kg
Shelf Configuration 2 standard shelves
Chamber Material Stainless-steel working chamber
Exterior Finish Coated cabinet exterior
Ambient Condition Note When set temperature is below 10 C, ambient temperature should be below 26 C.
Performance Features
  • Microcomputer control with LCD display allows operators to view set temperature, current temperature and timing status directly, improving day-to-day monitoring efficiency.
  • PID temperature control helps reduce fluctuation during operation, which is useful for culture storage, incubation consistency and routine repeatability.
  • The 0-50 C temperature control range gives this model flexibility for low-temperature storage, constant-temperature holding and general biochemical incubation workflows.
  • The 30 L chamber size supports routine sample batches without making the cabinet unnecessarily large for standard benchside or floor-standing laboratory use.
  • Stainless-steel chamber construction supports cleanliness, corrosion resistance and easier interior maintenance after repeated laboratory use.
  • Removable shelves make it easier to adjust internal layout for bottles, flasks, culture containers and other routine laboratory items.
  • The magnetic door sealing structure improves closing convenience and chamber tightness, helping reduce unnecessary disturbance during operation.
  • The inner door structure and visual observation design help users check chamber conditions more conveniently while reducing frequent full-door opening.
  • Built-in timing from 0 to 9999 min supports scheduled operation and reduces the need for continuous manual supervision.
  • The circulation fan and air-duct structure described for this series help improve chamber temperature uniformity, which is beneficial for more consistent incubation conditions across the usable space.
  • Functions such as self-diagnosis, over-temperature limit support and power-failure memory help strengthen operational reliability in routine laboratory environments.
APPLICATION SCOPE: Suitable for bacteria and mold culture, microorganism preservation, BOD-related work, water analysis, plant cultivation, breeding tests, sample holding and other laboratory workflows that require controlled temperature management in research, teaching, inspection and technical support environments.
PACKAGING: The equipment is prepared with protective inner materials and reinforced outer packaging to improve cushioning, stability and handling protection during storage, transfer and delivery. Additional reinforcement measures can be arranged according to order quantity and transport conditions.
IMPORTANT NOTICE: Please confirm nominal capacity, installation size, power supply and required configuration before quotation. Freight is quoted separately and the listed price does not include freight. When the set temperature is below 10 C, ambient temperature should be below 26 C. If custom dimensions or special configuration are required, contact our technical sales team by e-mail.
LABORATORY PROCUREMENT SUPPORT
For model selection, capacity matching, power supply confirmation or configuration review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

Manufacturer: Atomfair LLC

Brand: ATOMFAIR®

The incubator requires specific ambient temperature conditions for low-temperature operation. When the set temperature is below 10°C, ambient temperature must be below 26°C to maintain performance.

  • Low-Temperature Ambient Constraint: When the set temperature is below 10°C, ambient temperature must be below 26°C to ensure accurate temperature control and prevent condensation or compressor issues.

How does the temperature uniformity of ±2°C in the 30L biochemical incubator impact incubation consistency, and what design features help achieve this uniformity?

The temperature uniformity is specified as ±2°C across the chamber. The incubator incorporates a circulation fan and air-duct structure to improve temperature uniformity, which helps maintain more consistent incubation conditions across the usable space. This is suitable for routine microbiology culture and BOD work where moderate uniformity is acceptable.

What ambient temperature conditions are required when operating the 30L biochemical incubator at set points below 10°C?

When the set temperature is below 10°C, the ambient temperature must be below 26°C to ensure proper operation. This is a critical installation constraint for low-temperature applications such as microorganism preservation or BOD analysis.

What are the electrical power requirements and physical dimensions for installing the 30L biochemical incubator?

The incubator requires an AC 220V, 50Hz power supply with a rated power of 500W. The external dimensions are 500 x 520 x 965 mm, and the net weight is 45 kg. The working chamber is 260 x 350 x 350 mm. Ensure adequate bench or floor space and electrical capacity before installation.

The 30L General Biochemical Incubator (AF-BI30-T50) provides a 0-50°C temperature range with ±1°C control accuracy and ±2°C uniformity, suitable for BOD work, microbial culture, and low-temperature sample holding. However, its 500W fixed power supply (AC 220V, 50 Hz) and ambient temperature constraint—requiring ambient below 26°C when set below 10°C—limit deployment flexibility in labs with non-standard electrical infrastructure or elevated ambient heat loads.

Positive

  • Stainless-steel chamber for clean operation: The stainless-steel working chamber supports corrosion resistance and easier decontamination after repeated use, reducing maintenance overhead in routine microbiology and biochemical workflows.
  • PID control with LCD status display: Microcomputer PID control and direct-read LCD improve temperature stability and monitoring efficiency, supporting consistent incubation conditions for culture storage and BOD-related tasks.

Trade-offs

  • Ambient temperature constraint at low setpoints: When set temperature is below 10°C, ambient temperature must be below 26°C to maintain performance—this limits placement in unconditioned or warm laboratory environments without supplementary cooling.
  • Fixed 220V/50Hz power supply requirement: The 500W unit is designed for AC 220V, 50 Hz only; laboratories with 60 Hz mains or different voltage standards require external voltage conversion or frequency adaptation, adding infrastructure overhead.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).