250L Low-Temperature Incubator, -40-65℃ Temperature Control Range
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, specification comparison, accessory review, or quotation support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
Operate the incubator only within an ambient temperature range of 5 to 35°C and connect to a dedicated AC380V 50Hz power supply rated for 6100 W. Ensure the unit is placed on a level, stable surface with adequate clearance for the cooling system's airflow circulation.
- Ambient Temperature Constraint: The ambient temperature must be maintained between 5 and 35°C to prevent overheating or cooling system failure.
- Power Supply Constraint: The unit requires a dedicated AC380V 50Hz power supply capable of delivering 6100 W to avoid electrical overload.
- Placement and Ventilation Constraint: Place the incubator on a level, stable surface with sufficient space around the unit to allow proper airflow for the compressor and circulation fan.
Position the incubator in a location meeting the ambient temperature and ventilation requirements, then connect to the specified power supply. Configure the temperature and timer using the microcomputer controller to begin incubation.
- Position the incubator
Position the incubator on a level surface in an area with ambient temperature between 5 and 35°C. - Connect power supply
Connect the power cord to a dedicated AC380V 50Hz outlet capable of supplying 6100 W. - Set temperature and timer
Set the desired temperature within the -40 to 65°C range and the timer duration using the microcomputer controller.
Why does the temperature fluctuation specification differ between high-temperature and low-temperature operation for the 250L low-temperature incubator?
The published fluctuation is ±0.5°C at high temperatures and ±1.0°C at low temperatures due to the inherent challenges of maintaining stability near the lower end of the compressor-driven cooling range. The unit uses a compressor and circulation fan with an environmentally oriented refrigerant; at sub-ambient setpoints, the cooling system must work harder, leading to slightly wider fluctuation. This is a known trade-off in single-compressor systems operating across a -40 to 65°C span.
What are the electrical infrastructure requirements for installing this 250L low-temperature incubator?
The incubator requires an AC380V 50Hz power supply with an input power of 6100 W. This typically corresponds to a three-phase electrical connection, which is common in industrial and research laboratory settings but may not be available in standard single-phase outlets. Laboratories must verify their electrical panel capacity and outlet configuration before installation. The unit also requires an ambient temperature of +5 to 35°C for proper operation.
Can the incubator be equipped with data logging and remote monitoring capabilities for long-term stability tests?
Yes, the incubator supports optional accessories including an embedded printer, RS485 communication interface, and USB data transfer for selected configurations. These allow recording of temperature changes over time. Additionally, an independent over-temperature alarm system is available where supported, and a multi-segment programmable controller can be specified for automated temperature profiling. Availability and lead time should be confirmed by email before ordering.
This 250L low-temperature incubator provides a -40 to 65°C range with 0.1°C resolution and published fluctuation of ±0.5°C at high temperatures and ±1.0°C at low temperatures, enabling sub-ambient incubation, preservation, and stability testing. The 6100 W input power and AC380V 50Hz supply require dedicated electrical infrastructure, and the optional RS485 or USB logging accessories may need lead-time verification.
Positive
- Wide sub-ambient temperature range: The -40 to 65°C range supports low-temperature cultivation, preservation, and stability testing beyond standard constant-temperature incubators, making it suitable for sample preservation and near-ambient incubation tasks.
- Fine temperature resolution and control: 0.1°C resolution with high temp fluctuation of ±0.5°C and low temp ±1.0°C allows finer setpoint adjustment and repeatable chamber conditions for routine cultivation and preservation cycles.
Trade-offs
- High electrical infrastructure requirement: The 6100 W input power and AC380V 50Hz supply demand dedicated three-phase electrical installation, which may not be available in standard lab benches or teaching facilities without retrofitting.
- Temperature fluctuation asymmetry at low end: Low-temperature fluctuation (±1.0°C) is double that at high temperature (±0.5°C), which may reduce precision for sensitive low-temperature incubation or preservation protocols requiring tighter stability.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).