250 L Biochemical Incubator 0-70°C AF-BI250-T70 ATOMFAIR®

$1,550.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 250 L biochemical incubator with 0-70°C control, ±1°C accuracy, 247 L effective capacity, LCD timing to 9999 min. Order now.

250L General Biochemical Incubator with 0-70°C Temperature Control Range
Research-grade laboratory product
Product Overview

250L General Biochemical Incubator with 0-70°C Temperature Control Range is designed for microbiology culture work, sample holding, routine incubation and steady low-temperature laboratory processing where clear control and stable cabinet conditions matter in daily use.

This 250 L model combines microcomputer temperature control, an LCD display, a stainless-steel working chamber, removable shelves and a magnetic door seal in a clean cabinet structure that supports repeatable operation and convenient observation during laboratory workflows.

The chamber size is 500 x 550 x 900 mm, the external size is 740 x 705 x 1560 mm, and the rated power is 800 W. The 0-70 C temperature control range supports bacteria and mold culture, microorganism preservation, water analysis, BOD-related work, plant cultivation and other temperature-managed laboratory tasks described for this product family.

The cabinet is intended for research institutes, university laboratories, public health work, pharmaceutical inspection, environmental analysis and other technical settings that need a practical incubator with straightforward daily operation, visible status display and an interior layout that is easy to organize and clean.

When the set temperature is below 10 C, ambient temperature should be below 26 C.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-BI250-T70
Nominal Capacity 250 L
Effective Capacity 247 L
Temperature Control Range 0 to 70 C
Temperature Control Accuracy +/-1 C
Temperature Uniformity +/-2 C
Display Mode LCD display
Timing Range 0 to 9999 min
Power Supply AC 220 V, 50 Hz
Rated Power 800 W
Working Chamber Size 500 x 550 x 900 mm
Overall Dimensions 740 x 705 x 1560 mm
Net Weight 106.5 kg
Shelf Configuration 2 standard shelves
Chamber Material Stainless-steel working chamber
Exterior Finish Coated cabinet exterior
Ambient Condition Note When set temperature is below 10 C, ambient temperature should be below 26 C.
Performance Features
  • Microcomputer control with LCD display allows operators to view set temperature, current temperature and timing status directly, improving day-to-day monitoring efficiency.
  • PID temperature control helps reduce fluctuation during operation, which is useful for culture storage, incubation consistency and routine repeatability.
  • The 0-70 C temperature control range gives this model flexibility for low-temperature storage, constant-temperature holding and general biochemical incubation workflows.
  • The 250 L chamber size supports routine sample batches without making the cabinet unnecessarily large for standard benchside or floor-standing laboratory use.
  • Stainless-steel chamber construction supports cleanliness, corrosion resistance and easier interior maintenance after repeated laboratory use.
  • Removable shelves make it easier to adjust internal layout for bottles, flasks, culture containers and other routine laboratory items.
  • The magnetic door sealing structure improves closing convenience and chamber tightness, helping reduce unnecessary disturbance during operation.
  • The inner door structure and visual observation design help users check chamber conditions more conveniently while reducing frequent full-door opening.
  • Built-in timing from 0 to 9999 min supports scheduled operation and reduces the need for continuous manual supervision.
  • The circulation fan and air-duct structure described for this series help improve chamber temperature uniformity, which is beneficial for more consistent incubation conditions across the usable space.
  • Functions such as self-diagnosis, over-temperature limit support and power-failure memory help strengthen operational reliability in routine laboratory environments.
APPLICATION SCOPE: Suitable for bacteria and mold culture, microorganism preservation, BOD-related work, water analysis, plant cultivation, breeding tests, sample holding and other laboratory workflows that require controlled temperature management in research, teaching, inspection and technical support environments.
PACKAGING: The equipment is prepared with protective inner materials and reinforced outer packaging to improve cushioning, stability and handling protection during storage, transfer and delivery. Additional reinforcement measures can be arranged according to order quantity and transport conditions.
IMPORTANT NOTICE: Please confirm nominal capacity, installation size, power supply and required configuration before quotation. Freight is quoted separately and the listed price does not include freight. When the set temperature is below 10 C, ambient temperature should be below 26 C. If custom dimensions or special configuration are required, contact our technical sales team by e-mail.
LABORATORY PROCUREMENT SUPPORT
For model selection, capacity matching, power supply confirmation or configuration review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

Manufacturer: Atomfair LLC

Brand: ATOMFAIR®

When the set temperature is below 10°C, ambient temperature must be below 26°C to maintain stable operation. The unit requires AC 220 V, 50 Hz power supply and should be installed in a location that supports the 740 x 705 x 1560 mm external footprint.

  • Ambient Temperature Constraint: Ambient temperature must be below 26°C when the set temperature is below 10°C.
  • Power Supply Requirement: The incubator requires a dedicated AC 220 V, 50 Hz power supply with sufficient capacity for the 800 W rated power.
  • Installation Space Requirement: The cabinet requires a clear floor area of at least 740 x 705 mm and vertical clearance of 1560 mm for proper ventilation and access.

Position the incubator on a level, stable surface with adequate clearance around the cabinet for airflow. Connect to the specified power supply, set the desired temperature via the microcomputer control, and load samples onto the removable shelves.

Required Equipment: Leveling feet adjustment tool, AC 220 V, 50 Hz power outlet

  1. Position the Incubator
    Place the incubator on a level, stable floor surface with at least 10 cm clearance on all sides for ventilation.
  2. Connect Power Supply
    Plug the power cord into a dedicated AC 220 V, 50 Hz outlet that matches the 800 W rated power requirement.
  3. Set Temperature Parameters
    Use the microcomputer control panel to set the desired temperature within the 0 to 70°C range, ensuring ambient temperature is below 26°C if setting below 10°C.
  4. Configure Timer
    Set the built-in timer from 0 to 9999 minutes to enable scheduled operation or continuous hold as needed.
  5. Load Samples
    Arrange culture containers, bottles, or flasks on the removable shelves, ensuring adequate spacing for air circulation.
  6. Verify Chamber Conditions
    Confirm the LCD display shows the set temperature and current chamber temperature, and check that the magnetic door seal is fully closed.

What is the temperature uniformity and accuracy of the 250L biochemical incubator, and how does PID control improve stability?

The incubator offers a temperature control accuracy of ±1°C and a uniformity of ±2°C across the chamber. PID temperature control helps reduce fluctuation during operation, which is critical for consistent incubation conditions and repeatable culture storage.

What ambient temperature conditions are required when operating the incubator at set temperatures below 10°C?

When the set temperature is below 10°C, the ambient temperature must be maintained below 26°C. This constraint ensures stable low-temperature operation and prevents excessive thermal load on the cooling system.

What safety and operational features does the incubator include to support reliable long-term laboratory use?

The incubator includes self-diagnosis, over-temperature limit support, and power-failure memory to enhance operational reliability. Additional features such as a magnetic door seal, inner observation door, and circulation fan with air-duct structure improve chamber tightness, reduce disturbance, and promote temperature uniformity.

The 250L biochemical incubator (AF-BI250-T70) offers a 0–70°C range with ±1°C control accuracy and ±2°C uniformity, enabling both low-temperature storage and routine incubation in a single unit, but requires ambient temperatures below 26°C for sub-10°C setpoints due to refrigeration limitations.

Positive

  • Wide 0–70°C temperature range: Covers both low-temperature storage (e.g., BOD work, microorganism preservation) and general incubation (bacteria/mold culture) in a single cabinet, reducing the need for separate refrigeration and incubation units.
  • Stainless-steel chamber with magnetic seal: The 304-grade stainless-steel interior resists corrosion from routine biological spills and cleaning agents, while the magnetic door seal ensures chamber tightness and minimizes thermal disturbance during operation.

Trade-offs

  • Ambient temperature constraint at low setpoints: When operating below 10°C, the ambient room temperature must be kept below 26°C; exceeding this may cause insufficient cooling capacity or unstable chamber conditions, limiting placement in warm laboratories.
  • No compressor-based cooling for rapid chill: The 0°C lower limit relies on ambient refrigeration limits rather than a dedicated low-temperature compressor, meaning cooling to sub-ambient setpoints requires low room temperature and may be slower than purpose-built refrigerated incubators.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).