Temperature and Humidity Chamber, 360 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This chamber requires a stable AC 220V 50Hz power supply and must be operated within specified ambient temperature limits to maintain performance. When set temperature is below 10°C, ambient temperature must not exceed 26°C; when set temperature exceeds 40°C, humidity setpoint should be kept below 80% to protect service life.
- Power Supply Requirement: The unit must be connected to a dedicated AC 220V 50Hz outlet with sufficient capacity for the 900W load.
- Ambient Temperature Limit: Ambient temperature must not exceed 26°C when the set temperature is 10°C or below.
- Humidity Setpoint Limit: Humidity setpoint should not exceed 80% when the set temperature is above 40°C.
- Handling and Positioning: Keep the chamber upright during transport and positioning, and maintain clear air paths around the unit.
- Service Space: Allow sufficient service space around the unit for ventilation and maintenance access.
Position the chamber on a level surface with adequate clearance and connect to a grounded AC 220V 50Hz power supply. Program the desired temperature and humidity parameters via the LCD controller, observing ambient temperature and humidity limits for safe operation.
Required Equipment: LCD controller
- Position the chamber
Position the chamber on a level surface with adequate clearance for ventilation and maintenance. - Connect power
Connect the unit to a grounded AC 220V 50Hz power outlet. - Program parameters
Program the desired temperature and humidity parameters via the LCD controller. - Verify ambient temperature
Verify that ambient temperature does not exceed 26°C when the set temperature is 10°C or below. - Confirm humidity limit
Confirm that humidity setpoint is below 80% when the set temperature exceeds 40°C.
What is the effective humidity control range when operating at elevated temperatures above 40°C?
When the set temperature exceeds 40°C, the humidity setpoint should generally not exceed 80% RH to protect service life. The standard humidity range is 50% to 90% RH, but at high temperatures the upper limit is reduced to 80% RH as stated in the configuration note.
What ambient temperature conditions are required when operating the chamber at low set temperatures (10°C or below)?
When the set temperature is 10°C or below, the ambient temperature should not exceed 26°C. This requirement is specified in the configuration note to ensure proper operation and avoid performance issues, given the chamber's temperature control range of 5 to 50°C.
What are the installation and handling requirements for the 360 L temperature and humidity chamber given its weight and dimensions?
The chamber weighs 129.5 kg with external dimensions 835 x 755 x 1695 mm. It must be kept upright during unloading and positioning, with clear air paths and sufficient service space around the unit for ventilation and maintenance. The unit is shipped with reinforced packaging for transport safety.
The Atomfair AF-HSP360BE 360 L temperature and humidity chamber provides a 304 stainless-steel work chamber with LCD-programmable control over 5–50 °C and 50–90% RH (±1 °C fluctuation, <8% RH deviation), making it suitable for microbial culture, BOD measurement, and stability testing. However, users must respect the ambient temperature constraint (≤26 °C when setpoint ≤10 °C) and the humidity derating (≤80% RH when setpoint >40 °C) to maintain operational stability.
Positive
- Stainless-steel chamber with self-diagnostics: The 304 stainless-steel working chamber and over-temperature self-limiting function protect samples and reduce contamination risk during extended culture or incubation runs.
- Power-off memory and programmable cycling: Memory retention after power interruption preserves critical settings, while the LCD controller supports programmable temperature, humidity, and time sequences for repeatable biological or environmental test protocols.
Trade-offs
- Ambient-temperature derating for low setpoints: When the set temperature is 10 °C or below, ambient temperature must not exceed 26 °C, which may require air-conditioned lab spaces or careful thermal isolation in warm environments.
- Humidity restricted at elevated temperatures: For setpoints above 40 °C, humidity should generally be kept below 80% RH to preserve equipment service life, limiting high-humidity/high-temperature combined testing.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).