Temperature and Humidity Chamber, 150 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The chamber ambient temperature must not exceed 26°C when the set temperature is 10°C or below. The humidity setpoint should not exceed 80% when the set temperature is above 40°C to protect service life.
- Ambient temperature limit at low setpoints: When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C.
- Humidity limit at high setpoints: When the set temperature is above 40°C, the humidity setpoint should generally not exceed 80%.
- Power supply requirement: The chamber requires a grounded AC 220V 50Hz power supply with a 600W input capacity.
- Ventilation and spacing requirement: Maintain clear air paths and allow sufficient service space around the unit for ventilation and maintenance.
- Upright handling requirement: Keep the chamber upright during unloading, positioning, and transport to prevent damage.
Position the chamber in a well-ventilated area with adequate clearance and connect to a grounded power supply. Set the desired temperature and humidity parameters via the LCD controller and allow the chamber to stabilize before loading samples.
- Position the chamber
Position the chamber on a level surface with clear air paths and sufficient service space around the unit. - Connect to power
Connect the power cord to a grounded AC 220V 50Hz outlet. - Set parameters
Set the desired temperature and humidity parameters via the LCD controller. - Check ambient temperature for low setpoints
If the set temperature is 10°C or below, verify that the ambient temperature does not exceed 26°C. - Adjust humidity for high setpoints
If the set temperature is above 40°C, ensure the humidity setpoint is kept below 80%. - Confirm power-off recovery
After power interruptions, confirm the chamber resumes operation with the stored settings.
What are the operational limits for temperature and humidity setpoints in the Atomfair AF-HSP150BE 150 L chamber?
The chamber operates within a temperature range of 5 to 50 °C and humidity range of 50% to 90% RH. However, when the set temperature is 10 °C or below, the ambient temperature must not exceed 26 °C. When the set temperature is above 40 °C, humidity setpoints should generally not exceed 80% to protect service life. Additionally, temperature fluctuation is ±1 °C and humidity deviation is less than 8% RH.
What ambient temperature conditions are required for the AF-HSP150BE chamber to operate at low temperature setpoints?
For reliable low-temperature operation, when the set temperature is 10 °C or below, the ambient temperature must not exceed 26 °C. The chamber is powered by AC 220 V, 50 Hz and draws 600 W. The internal dimensions are 395 x 500 x 750 mm, and the unit weighs 82.5 kg, requiring adequate floor space and service clearance.
How does the power-off memory and self-diagnosis feature protect samples in the Atomfair AF-HSP150BE chamber?
The power-off memory preserves all temperature, humidity, and timer settings after an interruption, allowing continuous workflows without manual reprogramming. The self-diagnosis and over-temperature self-limiting functions reduce operational risk by automatically detecting and responding to abnormal conditions. The magnetic outer door seal and tempered-glass inner door further improve sealing and observation, minimizing heat loss during sample checks.
The Atomfair AF-HSP150BE 150 L temperature and humidity chamber provides programmable control with self-diagnosis and power-off memory, supporting reproducible biological and environmental testing. Operational constraints include reduced humidity capability above 40°C and ambient temperature limits when operating below 10°C.
Positive
- Self-diagnosis and over-temperature protection: Built-in self-diagnosis and over-temperature self-limiting reduce risk to samples and support reliable unattended operation.
- Power-off memory for workflow continuity: Power-off memory preserves temperature, humidity, and time settings after interruptions, enabling continuous experimental protocols without reprogramming.
Trade-offs
- Humidity limited at high temperatures: When set temperature exceeds 40°C, humidity setpoints should generally not exceed 80% RH to protect chamber service life.
- Ambient temperature constraint at low setpoints: When set temperature is 10°C or below, ambient room temperature must not exceed 26°C to maintain stable operation.