Forced-Air Constant Temperature Incubator, 80 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The incubator requires an ambient temperature of RT+5 to 70 °C and a power supply of AC220V/50Hz for stable operation. The unit must remain upright during unloading and positioning to prevent damage to the internal heating and circulation system.
- Temperature Uniformity Constraint: Maintain unobstructed air-circulation paths inside the chamber to achieve the specified temperature uniformity of ±1.5 °C.
- Shelf Load and Configuration Constraint: Verify shelf load capacity and chamber space before installation, and confirm that the selected stainless-steel configuration (304 or 316) meets the intended application's corrosion-resistance requirements.
Position the incubator on a level surface with adequate clearance for air circulation and connect it to a grounded AC220V/50Hz power outlet. Configure the PID controller and automatic three-speed fan to maintain the target temperature for microbial culture or stability testing.
Required Equipment: Level surface with clearance, Grounded AC220V/50Hz power outlet
- Unpack and position the incubator
Unpack the incubator and place it on a level surface, keeping the unit upright during unloading and positioning. - Connect to power supply
Connect the incubator to a grounded AC220V/50Hz power outlet and verify that the power cord is securely inserted. - Set the target temperature on the PID controller
Set the desired incubation temperature on the LCD liquid crystal controller, ensuring it is within the RT+5 to 70 °C range. - Configure the automatic fan speed
Select the automatic three-speed fan mode to optimize air circulation and energy efficiency as the chamber approaches the set temperature. - Load samples onto shelves
Place samples on the removable shelves, ensuring that air-circulation paths remain unobstructed for uniform temperature distribution. - Monitor chamber conditions using the observation light
Use the independent lighting switch to observe samples without opening the door, minimizing thermal disturbance during incubation.
How does the forced-air circulation system with automatic three-speed fan control affect temperature uniformity across the 80 L chamber at different setpoints?
The forced-air system with automatic three-speed fan adjustment, combined with PID heating control, maintains a temperature uniformity of ±1.5°C and fluctuation of ±0.5°C across the 80 L chamber (RT+5 to 70°C range). The fan automatically reduces speed near the target temperature to improve circulation uniformity and energy efficiency, but the ±1.5°C specification represents the worst-case spatial variation, so load placement and airflow path management are critical for applications requiring tighter gradients.
Is the Atomfair AF-DHP80C forced-air incubator compatible with 110V/60Hz power supplies, or does it require a step-down transformer for international use?
The incubator is specified for AC220V/50Hz power input at 400 W and does not list dual-voltage or 110V/60Hz compatibility. For use in regions with 110V/60Hz mains, a step-down transformer rated for at least 400 W continuous load and 50/60 Hz tolerance is required. The power supply must be confirmed before installation to avoid damage to the PID controller and fan system.
What material and shelf customization options are available for handling corrosive or high-humidity incubation environments?
The standard chamber is 304 stainless steel with two removable shelves, but the model supports customization to 316 stainless steel for enhanced corrosion resistance, as well as perforated or non-perforated shelf options. These options are intended for demanding laboratory applications such as drug stability testing or high-humidity microbial culture where standard 304 stainless might be insufficient. Customization must be specified at order; the page does not list separate pricing or lead times for these options.
The Forced-Air Constant Temperature Incubator (80 L) provides stable temperature control from RT+5 to 70°C with ±0.5°C fluctuation and ±1.5°C uniformity, featuring a 304 stainless-steel chamber and automatic 3-speed fan for energy-efficient operation.
Positive
- Automatic 3-speed fan control: Reduces energy consumption near setpoint and improves temperature uniformity throughout the chamber.
- 304 stainless-steel chamber: Corrosion-resistant and easy to clean, supporting long-term laboratory use and routine decontamination.
Trade-offs
- Temperature range limited to RT+5 to 70°C: Cannot operate below ambient plus 5°C, making it unsuitable for low-temperature incubation or cold storage applications.
- Temperature uniformity ±1.5°C: May not meet stringent uniformity requirements for certain sensitive biological assays or stability tests requiring tighter thermal gradients.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).