Constant Temperature Incubator 136 L AF-HN136BS ATOMFAIR®

$780.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

136 L precision constant temperature incubator with AF-HN136BS model, RT+5 to 100 °C range, 0.1 °C resolution, 600 W input and stainless-steel liner. Order now.

SKU: AF-LE-E-HNCI-0136-40B1
Category:
Brands:

Precision Constant Temperature Incubator, 136 L, Stainless-Steel Interior
Research-grade laboratory product
Product Overview

Precision Constant Temperature Incubator, 136 L, Stainless-Steel Interior is a practical chamber for bacterial culture, fermentation, constant-temperature experiments and laboratory incubation tasks. It brings together 136 l of usable space, RT+5 to 100 C, so the chamber can keep samples in a steady, repeatable working condition.

The series features a cleanable chamber layout, adjustable shelf spacing, a top exhaust valve for moisture removal and a silicone sealing ring that helps with insulation and noise reduction. The cabinet uses a vertical frame cabinet with high-quality cold-rolled plate forming, a powder-coated exterior, a silicone sealing ring and a top exhaust vent, with an internal working room of 450 x 550 x 550 mm and an external footprint of 585 x 700 x 860 mm. That combination of chamber size, shell build and liner material makes the unit easier to place, clean and use in routine laboratory work.

The series uses natural convection and precise temperature control to keep the chamber stable for routine culture and thermal test work. The stated input power is 600 W, and the timer range is 0 to 9999 min. It is well suited to the day-to-day work listed above, including culture, incubation, climate simulation or illuminated growth tasks, depending on the family.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-HN136BS
Capacity 136 L
Temperature Control Range RT+5 to 100 C
Temperature Resolution 0.1 C
Temperature Fluctuation +/- 0.5 C
Controller Smart digital PID controller with timing, over-temperature alarm, deviation correction and self-tuning
Chamber Material Thickened stainless-steel inner liner
Exterior Shell Cold-rolled steel shell with electrostatic powder coating
Power / Input 600 W
Power Supply AC220V 50Hz
Timer Range 0 to 9999 min
Internal Dimensions 450 x 550 x 550 mm
External Dimensions 585 x 700 x 860 mm
Net Weight 50 Kg
Shelves / Trays 2 shelves
Operating Mode Natural convection
Configuration Note BS version uses a thickened stainless-steel liner
Optional Accessories and Functions RS485/232 interface and communication software; embedded printer; USB data storage; wireless alarm system; CO2 inlet; CO2 controller; light-intensity detection and control system
Performance Features
  • PID temperature control supports accurate setpoint management during routine incubation. This supports more stable setpoint tracking and quicker recovery after door openings.
  • Timing, over-temperature alarm, deviation correction and self-tuning improve operating safety and ease of use. This helps protect samples and alerts operators when abnormal conditions occur.
  • Natural convection provides stable temperature distribution for standard incubation tasks. This supports more reliable day-to-day chamber use.
  • Silicone sealing and a top exhaust vent help maintain insulation while releasing moisture. This supports more reliable day-to-day chamber use.
  • Powder-coated cold-rolled steel construction improves cabinet durability and appearance. This supports more reliable day-to-day chamber use.
  • The S and BS liner options support different cleaning and corrosion-resistance preferences. This supports more reliable day-to-day chamber use.
APPLICATION SCOPE: Suitable for bacterial culture, fermentation, constant-temperature experiments and laboratory incubation tasks in universities, laboratories, research institutes and quality-control environments that need controlled chamber performance.
HANDLING: Check the liner type, shelving and installation space before placing the unit. Keep the exhaust vent clear and avoid blocking the cabinet airflow path. Every unit is shipped with reinforced packaging for transport safety; keep the unit upright during unloading and positioning.
IMPORTANT NOTICE: The controller supports timing, over-temperature alarm, temperature-deviation correction and self-tuning functions. The optional accessories listed on this page are communication, printing, USB storage, alarm and gas-intake add-ons. Any quoted amount refers to the chamber body only and does not include freight. Freight should be confirmed separately according to the delivery destination.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator requires unobstructed airflow and a clear exhaust vent to maintain temperature stability. The unit must be installed on a level surface with access to a 220V 50Hz power supply and adequate clearance for ventilation.

  • Airflow and Exhaust Constraint: Keep the exhaust vent clear and avoid blocking the cabinet airflow path to prevent overheating and ensure uniform temperature distribution.
  • Power Supply Requirement: Connect the incubator to a 220V 50Hz power outlet with sufficient capacity for the 600W input power.
  • Installation Preparation: Verify the liner material, shelf configuration, and available space before positioning the unit to ensure proper fit and operation.

How does the PID controller with self-tuning and deviation correction maintain temperature accuracy in the Atomfair AF-HN136BS incubator?

The PID controller supports accurate setpoint management with a temperature resolution of 0.1°C and fluctuation of ±0.5°C. Self-tuning and deviation correction improve stability and quicker recovery after door openings, while the over-temperature alarm protects samples during prolonged use.

What external monitoring and data logging options are available for the 136L constant temperature incubator?

Optional accessories include RS485/232 interface and communication software, an embedded printer, USB data storage, a wireless alarm system, and CO2 inlet/controller. These allow integration with laboratory information systems and remote monitoring.

What are the key installation and safety considerations for the AF-HN136BS incubator?

The unit requires a AC220V 50Hz power supply and 600W input. Keep the exhaust vent clear and avoid blocking airflow. The controller includes timing, over-temperature alarm, and deviation correction for safe operation. The silicone sealing ring helps insulation and noise reduction. Keep the unit upright during transport.

The AF-HN136BS precision constant temperature incubator provides 136 L of usable volume with a PID controller and natural convection, delivering ±0.5 °C temperature fluctuation from RT+5 to 100 °C for routine bacterial culture and fermentation tasks. Its thickened stainless-steel liner and powder-coated cold-rolled steel shell offer corrosion resistance and durability, while the silicone sealing ring and top exhaust vent manage moisture and insulation trade-offs in continuous lab operation.

Positive

  • PID control with self-tuning: Smart digital PID controller with timing, over-temperature alarm, deviation correction, and self-tuning enables accurate setpoint management and faster recovery after door openings, improving sample protection during routine incubation.
  • Thickened stainless-steel liner: The BS version uses a thickened stainless-steel inner liner that resists corrosion and simplifies cleaning, supporting long-term use in bacterial culture and constant-temperature experiments.

Trade-offs

  • Natural convection limits uniformity: Natural convection mode provides stable temperature distribution for standard tasks but may exhibit slower thermal equilibration and less uniformity than forced-air designs, particularly under heavy loading or frequent door openings.
  • Power supply and infrastructure constraints: The unit requires AC220V 50Hz input at 600 W, which may necessitate dedicated circuit planning in labs with non-standard mains voltage or frequency, and the 50 kg net weight demands adequate bench or floor support.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).