Programmable Touchscreen Constant Temperature and Humidity Chamber, 800 L,-10-100℃
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The chamber must be operated within an ambient temperature range of +5 to 30°C and connected to a dedicated AC 380 V, 50 Hz power supply rated at 8050 W. Installation requires a minimum space of 860 x 1340 x 1995 mm and the chamber must be transported upright using suitable lifting equipment.
- Environmental Constraint: Operate the chamber only within an ambient temperature range of +5 to 30°C.
- Electrical Constraint: Connect the chamber to a dedicated AC 380 V, 50 Hz power supply rated at 8050 W.
- Space Constraint: Allocate installation space of at least 860 x 1340 x 1995 mm for the chamber body.
- Handling Constraint: Transport the chamber upright and use suitable lifting equipment for unloading and positioning.
- Maintenance Access Constraint: Keep air inlets, test ports, shelving, drain areas, doors, and controller surfaces accessible for cleaning and maintenance.
This procedure covers the initial installation and positioning of the constant temperature and humidity chamber. Follow these steps to ensure safe setup and proper operation of the unit.
Required Equipment: Lifting equipment
- Confirm Installation Space
Confirm the installation space against the chamber's external dimensions of 860 x 1340 x 1995 mm. - Prepare Power Supply
Prepare the specified power supply of AC 380 V, 50 Hz with a capacity of 8050 W. - Ensure Accessibility
Ensure that air inlets, test ports, shelving, drain areas, doors, and controller surfaces remain accessible for cleaning and maintenance. - Transport Upright
Keep the packed chamber upright during transport to prevent damage. - Use Lifting Equipment
Use suitable lifting equipment during unloading and positioning to move the chamber safely.
What is the temperature uniformity specification for the Atomfair BPS-800CL chamber at low temperature versus high temperature operation?
The chamber maintains ±0.5°C uniformity at high temperature (above 0°C) and ±1.0°C at low temperature (below 0°C), as stated in the technical specifications. This performance difference should be considered when planning experiments that require tight uniformity at sub-zero setpoints.
What electrical infrastructure is required to install the Atomfair BPS-800CL 800L constant temperature and humidity chamber?
The chamber requires a 380 V, 50 Hz AC power supply with a rated input of 8050 W. The working environment must be between 5 and 30°C. Ensure the installation site has a dedicated circuit meeting these specifications, and that the external dimensions of 860 x 1340 x 1995 mm are accommodated with adequate ventilation and access for maintenance.
What safety protections are integrated into the Atomfair BPS-800CL chamber to prevent sample loss during extended tests?
The chamber includes independent alarm and protection functions covering over-temperature, overload, over-current, fan, and compressor conditions. These safety systems help maintain stable operation and protect samples during long-duration protocols. Optional wireless alarm and RS485 communication provide remote notification of abnormal conditions, reducing operational risk.
The Atomfair BPS-800CL 800 L constant temperature and humidity chamber provides a high-capacity programmable controller with PID auto-tuning and balancing refrigeration, but requires a 380V power supply and has a +/-3%RH humidity deviation that may constrain precision applications.
Positive
- High-capacity program control: The touchscreen controller supports up to 100 programs, 1000 segments, and 999 cycle steps, enabling staged environmental test methods with complex profiles.
- PID auto-tuning for stability: PID self-tuning reduces deviation in temperature and humidity, improving control stability for sensitive applications like incubation and conditioning.
Trade-offs
- Non-standard 380V power requirement: The chamber requires a 380V, 50Hz power supply with 8050W capacity, which may not be available in all laboratory facilities and requires dedicated electrical infrastructure.
- Humidity accuracy limitation: The specified humidity deviation of +/-3%RH may be insufficient for applications requiring tighter humidity control, such as precise pharmaceutical stability studies.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).