Programmable Touchscreen Constant Temperature and Humidity Chamber, 250 L,-20-100℃ is a programmable touchscreen constant temperature and humidity chamber built for scientific research, biotechnology tests, pharmaceutical packaging, industrial raw-material studies and product lifetime evaluation. This configuration provides 250 l chamber volume, -20 to 100 C, 35%rh to 95%rh humidity control, imported 304 mirror-finish stainless-steel chamber interior and programmable color touchscreen controller with curve display and multi-language interface for stable day-to-day laboratory operation.

This family combines fluorine-free design, imported 304 stainless-steel inner chamber construction, balancing temperature-humidity control, test-port access and color-touchscreen editing as key chamber elements. The chamber combines balancing-control refrigeration system with multi-point safety protection with high-temperature humidity sensor for real-time monitoring, 3 shelves and an interior size of 600 x 500 x 820 mm, supporting incubation, cultivation, climate simulation or conditioned test work where repeatable environmental control is important.

This range is intended for laboratories that want staged touchscreen programs, multilingual interface, stored curves, PID self-tuning and safety protection in one humidity-chamber platform. Installation planning can be based on the external size of 750 x 900 x 1580 mm and the stated power requirement of 2700 W. Optional functions such as embedded printer; rs485 communication interface and software; wireless alarm system; communication interface and embedded printer are alternative options that should be selected according to the required configuration allow the unit to be adapted for alarm notification, data output, programmable operation, atmosphere support or other application-specific requirements.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-BCA0250
Manufacturer Model BPS-250CA
Capacity 250 L
Temperature Control Range -20 to 100 C
Temperature Resolution 0.1 C
Temperature Fluctuation / Uniformity High temperature: +/- 0.5 C; low temperature: +/- 1 C
Humidity Function 35%RH to 95%RH
Humidity Deviation +/- 3%RH
Controller programmable color touchscreen controller with curve display and multi-language interface
Chamber Material imported 304 mirror-finish stainless-steel chamber interior
Power / Input 2700 W
Power Supply AC 220 V, 50 Hz
Working Environment +5 to 30 C
Sensor Configuration high-temperature humidity sensor for real-time monitoring
Cooling System balancing-control refrigeration system with multi-point safety protection
Internal Dimensions 600 x 500 x 820 mm
External Dimensions 750 x 900 x 1580 mm
Shelves / Light Decks 3 shelves
Program Function Touchscreen controller supports up to 100 programs, 1000 segments and 999 cycle steps, with a maximum time setting of 99 h 59 min per segment
Optional Accessories and Functions embedded printer; RS485 communication interface and software; wireless alarm system; communication interface and embedded printer are alternative options that should be selected according to the required configuration
Performance Features
  • Color touchscreen operation helps simplify program editing, parameter review and real-time curve observation during chamber use. This improves parameter review, setpoint editing and day-to-day operation in controlled chamber workflows.
  • Large program capacity supports staged environmental methods that need repeated cycles and multiple segments. This supports staged test methods and repeatable laboratory workflows that need cycle-based control.
  • PID auto-tuning helps correct temperature and humidity deviations quickly for more stable chamber control. This supports humidity-sensitive incubation, cultivation, conditioning and stability-study applications.
  • Balancing-control refrigeration and imported stainless-steel chamber construction support reliable long-duration operation. This helps support repeated cleaning, chamber hygiene and long-duration laboratory use.
  • Independent alarm and protection functions cover over-temperature, overload, over-current, fan and compressor conditions. This helps maintain dependable low-temperature performance and stable chamber recovery during repeated use.
  • Optional communication, printer and wireless-alarm functions make it easier to store, replay and supervise chamber records. This reduces operational risk by helping protect samples and notifying operators when abnormal conditions occur.
APPLICATION SCOPE: Suitable for scientific research, biotechnology tests, pharmaceutical packaging, industrial raw-material studies and product lifetime evaluation in universities, research institutes, pharmaceutical quality-control laboratories, agricultural research programs and industrial test environments that require controlled chamber operation.
HANDLING: Confirm installation space against 750 x 900 x 1580 mm, prepare the specified power supply, and keep air inlets, test ports, shelving, drain areas, doors and controller surfaces accessible for cleaning and maintenance. Every unit is shipped with reinforced packaging to reduce movement and impact during transport; keep the packed chamber upright and use suitable lifting equipment during unloading and positioning.
IMPORTANT NOTICE: Confirm the exact controller type, lighting form, humidity function, communication option and accessory package before ordering. Any displayed amount refers to the chamber body only and does not include freight. Freight is quoted separately and should be confirmed according to the delivery location and shipping method.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This chamber requires a controlled ambient environment and a dedicated power supply for safe operation. Proper handling during transport and positioning is essential to prevent damage to the refrigeration system.

  • Ambient Temperature Range: The working environment must be maintained between 5°C and 30°C to ensure stable refrigeration and humidity control.
  • Power Supply Requirements: A dedicated AC 220 V, 50 Hz power supply with a capacity of 2700 W and proper grounding is required.
  • Ventilation and Access: Air inlets, test ports, and controller surfaces must remain unobstructed for adequate airflow and operational access.
  • Transport Orientation: The chamber must be kept upright during transport and positioning to prevent refrigerant migration or compressor damage.
  • Interior Hygiene: The 304 stainless-steel interior should be cleaned regularly to maintain chamber hygiene and prevent corrosion.

Installation involves verifying space and power requirements, unpacking with care, and positioning for accessibility. Programming the touchscreen controller with staged parameters enables automated environmental testing.

Required Equipment: Lifting equipment

  1. Verify Installation Space
    Confirm that the installation space meets the external dimensions of 750 x 900 x 1580 mm with adequate clearance for ventilation and maintenance.
  2. Confirm Power Supply
    Verify that the power supply matches the requirement of 2700 W, AC 220 V, 50 Hz with proper grounding.
  3. Unpack Chamber
    Unpack the chamber while keeping it upright and using suitable lifting equipment to avoid shock or tipping.
  4. Position Chamber
    Position the chamber so that air inlets, test ports, and controller surfaces remain accessible for operation and cleaning.
  5. Configure Controller Program
    Program the touchscreen controller with the desired temperature and humidity setpoints, program segments, and cycle steps for the test protocol.

What is the temperature uniformity specification for the Atomfair BPS-250CA chamber at high versus low temperature extremes?

At high temperature, uniformity is ±0.5°C; at low temperature, it is ±1°C. This is specified in the technical specifications for the 250L constant temperature and humidity chamber.

Does the Atomfair BPS-250CA support humidity control below 35%RH?

No, the humidity control range is 35%RH to 95%RH with a deviation of ±3%RH. The chamber does not support humidity below 35%RH as per the product specifications.

What are the installation space and power requirements for the 250L constant temperature and humidity chamber?

The external dimensions are 750 x 900 x 1580 mm, and the power requirement is 2700 W at AC 220V, 50 Hz. The working environment temperature should be between +5°C and 30°C. Ensure adequate clearance for air inlets and maintenance access.

The Atomfair BPS-250CA (SKU AF-LE-E-BPSC-0250-CA25) is a 250 L programmable temperature and humidity chamber with balancing-control refrigeration, a 304 stainless steel interior, and a color touchscreen controller supporting up to 100 programs and 1000 segments. It provides -20 to 100°C temperature control and 35% to 95% RH humidity control, making it suitable for incubation, stability testing, and climate simulation, but requires careful attention to power (2700 W, 220 V, 50 Hz) and ambient temperature (5-30°C) constraints.

Positive

  • Large programmable control capacity: The touchscreen controller supports up to 100 programs, 1000 segments, and 999 cycles with a maximum segment time of 99 h 59 min, enabling complex staged test protocols and repeatable cycles for long-duration studies.
  • Balancing refrigeration and stainless steel construction: The balancing-control refrigeration system combined with an imported 304 mirror-finish stainless steel interior provides stable temperature and humidity control, supports repeated cleaning, and ensures reliable long-term operation in laboratory environments.

Trade-offs

  • Infrastructure and power requirements: The chamber requires a 2700 W, AC 220 V, 50 Hz power supply and an ambient operating temperature range of +5 to 30°C, necessitating dedicated electrical and environmental planning in the laboratory.
  • Limited humidity and temperature precision: Humidity control is specified at ±3% RH deviation, and temperature uniformity is ±0.5°C at high temperatures and ±1°C at low temperatures, which may be insufficient for applications requiring tighter tolerances.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).