Programmable Humidity Chamber 50 L -40 to 100°C ATOMFAIR®

$12,000.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 50 L chamber with -40 to 100 °C temperature and 35-95%RH humidity control, 0.1 °C resolution, touchscreen programming, and 2 shelves.

SKU: AF-LE-E-BPSC-0050-CB50
Category:
Brands:

Programmable Touchscreen Constant Temperature and Humidity Chamber, 50 L,-40-100℃
Research-grade laboratory product
Product Overview

Programmable Touchscreen Constant Temperature and Humidity Chamber, 50 L,-40-100℃ is a programmable touchscreen constant temperature and humidity chamber built for scientific research, biotechnology tests, pharmaceutical packaging, industrial raw-material studies and product lifetime evaluation. This configuration provides 50 l chamber volume, -40 to 100 C, 35%rh to 95%rh humidity control, imported 304 mirror-finish stainless-steel chamber interior and programmable color touchscreen controller with curve display and multi-language interface for stable day-to-day laboratory operation.

This family combines fluorine-free design, imported 304 stainless-steel inner chamber construction, balancing temperature-humidity control, test-port access and color-touchscreen editing as key chamber elements. The chamber combines balancing-control refrigeration system with multi-point safety protection with high-temperature humidity sensor for real-time monitoring, 2 shelves and an interior size of 400 x 380 x 450 mm, supporting incubation, cultivation, climate simulation or conditioned test work where repeatable environmental control is important.

This range is intended for laboratories that want staged touchscreen programs, multilingual interface, stored curves, PID self-tuning and safety protection in one humidity-chamber platform. Installation planning can be based on the external size of 650 x 1040 x 1650 mm and the stated power requirement of 2650 W. Optional functions such as embedded printer; rs485 communication interface and software; wireless alarm system; communication interface and embedded printer are alternative options that should be selected according to the required configuration allow the unit to be adapted for alarm notification, data output, programmable operation, atmosphere support or other application-specific requirements.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-BCB0050
Manufacturer Model BPS-50CB
Capacity 50 L
Temperature Control Range -40 to 100 C
Temperature Resolution 0.1 C
Temperature Fluctuation / Uniformity High temperature: +/- 0.5 C; low temperature: +/- 1 C
Humidity Function 35%RH to 95%RH
Humidity Deviation +/- 3%RH
Controller programmable color touchscreen controller with curve display and multi-language interface
Chamber Material imported 304 mirror-finish stainless-steel chamber interior
Power / Input 2650 W
Power Supply AC 380 V, 50 Hz
Working Environment +5 to 30 C
Sensor Configuration high-temperature humidity sensor for real-time monitoring
Cooling System balancing-control refrigeration system with multi-point safety protection
Internal Dimensions 400 x 380 x 450 mm
External Dimensions 650 x 1040 x 1650 mm
Shelves / Light Decks 2 shelves
Program Function Touchscreen controller supports up to 100 programs, 1000 segments and 999 cycle steps, with a maximum time setting of 99 h 59 min per segment
Optional Accessories and Functions embedded printer; RS485 communication interface and software; wireless alarm system; communication interface and embedded printer are alternative options that should be selected according to the required configuration
Performance Features
  • Color touchscreen operation helps simplify program editing, parameter review and real-time curve observation during chamber use. This improves parameter review, setpoint editing and day-to-day operation in controlled chamber workflows.
  • Large program capacity supports staged environmental methods that need repeated cycles and multiple segments. This supports staged test methods and repeatable laboratory workflows that need cycle-based control.
  • PID auto-tuning helps correct temperature and humidity deviations quickly for more stable chamber control. This supports humidity-sensitive incubation, cultivation, conditioning and stability-study applications.
  • Balancing-control refrigeration and imported stainless-steel chamber construction support reliable long-duration operation. This helps support repeated cleaning, chamber hygiene and long-duration laboratory use.
  • Independent alarm and protection functions cover over-temperature, overload, over-current, fan and compressor conditions. This helps maintain dependable low-temperature performance and stable chamber recovery during repeated use.
  • Optional communication, printer and wireless-alarm functions make it easier to store, replay and supervise chamber records. This reduces operational risk by helping protect samples and notifying operators when abnormal conditions occur.
APPLICATION SCOPE: Suitable for scientific research, biotechnology tests, pharmaceutical packaging, industrial raw-material studies and product lifetime evaluation in universities, research institutes, pharmaceutical quality-control laboratories, agricultural research programs and industrial test environments that require controlled chamber operation.
HANDLING: Confirm installation space against 650 x 1040 x 1650 mm, prepare the specified power supply, and keep air inlets, test ports, shelving, drain areas, doors and controller surfaces accessible for cleaning and maintenance. Every unit is shipped with reinforced packaging to reduce movement and impact during transport; keep the packed chamber upright and use suitable lifting equipment during unloading and positioning.
IMPORTANT NOTICE: Confirm the exact controller type, lighting form, humidity function, communication option and accessory package before ordering. Any displayed amount refers to the chamber body only and does not include freight. Freight is quoted separately and should be confirmed according to the delivery location and shipping method.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

Operate the chamber within a working environment of +5 to 30°C and connect only to a 380V, 50Hz power supply. Maintain clear access to all air inlets, test ports, drains, and controller surfaces to ensure safe operation and maintenance.

  • Transport and Storage: Transport and store the chamber in an upright orientation to prevent damage to the refrigeration system.
  • Electrical Power: The chamber draws 2650W and requires a dedicated AC 380V, 50Hz circuit with appropriate over-current protection.
  • Ambient Temperature: Ambient temperature must remain between +5 and 30°C to maintain specified temperature and humidity control performance.
  • Accessibility: Keep air inlets, test ports, shelving, drain areas, doors, and controller surfaces unobstructed for cleaning and maintenance.

Confirm the installation space and prepare the required power supply before unpacking the chamber. Use suitable lifting equipment to maintain upright orientation during positioning.

Required Equipment: Suitable lifting equipment (e.g., forklift or pallet jack)

  1. Confirm Installation Space
    Confirm that the installation area accommodates the external dimensions of 650 x 1040 x 1650 mm with clearance for air inlets and drains.
  2. Prepare Power Supply
    Ensure the electrical supply meets the chamber's requirements of 2650W, AC 380V, 50Hz with a dedicated circuit.
  3. Unpack and Position Chamber
    Use suitable lifting equipment to unload the chamber while keeping it upright, then position it in the prepared location.
  4. Verify Accessibility
    Confirm that air inlets, test ports, shelves, drain areas, doors, and controller surfaces are all accessible for operation and maintenance.

What temperature uniformity and humidity deviation can be expected from the BPS-50CB constant temperature and humidity chamber?

The BPS-50CB chamber provides temperature fluctuation/uniformity of ±0.5°C at high temperature and ±1°C at low temperature, with humidity deviation of ±3%RH. These specifications are based on the balancing-control refrigeration system and PID auto-tuning described in the technical specifications.

Can the Atomfair BPS-50CB chamber be connected to external data logging or alarm systems?

Yes, the chamber supports optional RS485 communication interface and software, an embedded printer, and a wireless alarm system. These optional accessories allow data output, remote monitoring, and alarm notification, though they must be selected during configuration as they are not included as standard.

What are the power and installation space requirements for the 50L constant temperature and humidity chamber?

The chamber requires a power supply of AC 380V 50Hz with a rated input of 2650W. It has external dimensions of 650 x 1040 x 1650 mm, and the working environment should be +5 to 30°C. Installation planning should ensure adequate space for air inlets, test ports, and maintenance access.

The Atomfair BPS-50CB (50L) constant temperature and humidity chamber offers -40 to 100°C and 35-95%RH with a programmable touchscreen controller supporting 100 programs and 1000 segments, but requires 380V AC power and a controlled ambient environment of 5-30°C.

Positive

  • Large program capacity touchscreen controller: The controller supports up to 100 programs, 1000 segments, and 999 cycle steps with a maximum segment time of 99h 59min, enabling complex staged environmental test protocols without external programming.
  • Balancing-control refrigeration with PID auto-tuning: The balancing-control refrigeration system combined with PID auto-tuning corrects temperature and humidity deviations quickly, providing stable chamber conditions for long-duration incubation, cultivation, and stability studies.

Trade-offs

  • Requires 380V AC three-phase power: The chamber operates on AC 380V, 50Hz power supply, which is not standard in many laboratory facilities; additional electrical infrastructure or a step-up transformer may be needed.
  • Narrow ambient operating temperature range: The working environment is restricted to +5 to 30°C, meaning the chamber cannot be used in unconditioned spaces or extreme ambient conditions without additional climate control.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).