Programmable Touchscreen Constant Temperature and Humidity Chamber, 50 L,-10-100℃
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The chamber must be operated within an ambient temperature range of +5 to 30°C and connected to a dedicated AC 220V, 50Hz power supply. The unit must be transported and positioned upright using suitable lifting equipment, with all air inlets, test ports, drain areas, doors, and controller surfaces kept accessible for cleaning and maintenance.
- Ambient Operating Environment: The working environment must be maintained at +5 to 30°C to ensure proper cooling system function and component longevity.
- Power Supply Requirement: A dedicated AC 220V, 50Hz power supply capable of delivering 1700W is required; do not use extension cords or shared circuits.
- Transport and Positioning: The packaged chamber must remain upright at all times and be moved using suitable lifting equipment (e.g., forklift or pallet jack) to prevent damage to the refrigeration system.
- Accessibility for Maintenance: All air inlets, test ports, drain areas, doors, and the controller surface must remain unobstructed to allow routine cleaning and emergency access.
- Safety Protection Systems: Independent over-temperature, overload, over-current, fan, and compressor protection functions are integrated and must not be bypassed or disabled.
Confirm the installation space meets the external dimensions of 720 x 620 x 725 mm and prepare a dedicated AC 220V, 50Hz power supply. Position the chamber upright using suitable lifting equipment, then connect power and verify the touchscreen controller activates before setting parameters.
Required Equipment: Suitable lifting equipment (e.g., forklift or pallet jack), AC 220V, 50Hz power supply, Touchscreen controller interface
- Confirm Installation Space
Confirm the installation area can accommodate the chamber's external dimensions of 720 x 620 x 725 mm and allow clearance for ventilation and access. - Prepare Power Supply
Prepare a dedicated AC 220V, 50Hz power supply rated for at least 1700W. - Position the Chamber
Use suitable lifting equipment to unload and position the chamber upright on a level, stable surface. - Ensure Accessibility
Ensure all air inlets, test ports, drain areas, doors, and the controller surface are accessible for operation and maintenance. - Connect Power
Connect the power cord to the prepared AC 220V outlet and verify the touchscreen display activates. - Set Parameters
Set the desired temperature and humidity parameters using the programmable color touchscreen controller. - Allow Stabilization
Allow the chamber to stabilize at the set conditions before loading samples or initiating test cycles.
How does the temperature uniformity of the BPS-50CL chamber differ between high and low temperature setpoints?
The temperature uniformity is tighter at high temperatures (±0.5°C) compared to low temperatures (±1°C), as specified in the technical specifications. This variance is inherent to the balancing-control refrigeration system's performance across the -10 to 100°C range.
What are the ambient working environment requirements for the Atomfair BPS-50CL constant temperature and humidity chamber?
The chamber requires an ambient working environment of +5 to 30°C, as stated in the technical specifications. It also requires a dedicated AC 220V, 50Hz power supply with 1700W input. Installation planning must account for the external dimensions of 720 x 620 x 725 mm and ensure access for cleaning and maintenance.
What special handling precautions are needed when installing the 50L programmable temperature and humidity chamber?
The unit is shipped in reinforced packaging and must be kept upright during transport and unloading. Installation space must accommodate the external dimensions of 720 x 620 x 725 mm, and the specified power supply (AC 220V, 50Hz) must be prepared. Air inlets, test ports, shelving, drain areas, doors, and controller surfaces should remain accessible for cleaning and maintenance.
This 50 L programmable chamber provides -10 to 100°C temperature control and 35-95%RH humidity range with a balancing refrigeration system and PID auto-tuning, suitable for stability testing and material conditioning. The touchscreen controller supports up to 100 programs and 1000 segments for complex environmental profiles.
Positive
- Balancing control refrigeration: The balancing-control refrigeration system with multi-point safety protection supports reliable long-duration operation and stable temperature recovery during repeated use.
- PID auto-tuning for stability: PID auto-tuning helps correct temperature and humidity deviations quickly, providing more stable chamber control for humidity-sensitive incubation and conditioning workflows.
Trade-offs
- Narrow power and environment requirements: The chamber requires AC 220V, 50Hz supply and an operating environment of +5 to 30°C, limiting placement flexibility and requiring dedicated infrastructure.
- Limited humidity range: Humidity control is limited to 35-95%RH with ±3%RH deviation; it cannot achieve low-humidity conditions below 35%RH or high-humidity above 95%RH.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).