Professional Constant Temperature and Humidity Chamber, 250 L,with Printer
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The chamber must be operated within a specified ambient temperature range and connected to a dedicated power supply of the correct voltage and capacity. The over-temperature protection system and proper installation with accessible service points are mandatory for safe and reliable operation.
- Power Supply Requirement: Connect the chamber to a dedicated AC 220 V, 50 Hz power supply capable of delivering 2300 W to avoid electrical overload.
- Ambient Temperature Limit: Operate the chamber only in an ambient environment between +5 and 35 °C to ensure stable temperature and humidity control.
- Installation Clearance: Maintain adequate clearance around the chamber for air circulation and access to the side test port, drain, and controller.
- Over-Temperature Protection Check: Verify the independent over-temperature protection system is functional before each use to prevent sample damage or fire risk.
- Humidity Sensor Calibration: Calibrate the imported humidity sensor periodically according to the manufacturer's instructions to maintain humidity accuracy within ±3% RH.
Follow these steps to properly unpack, install, and begin operation of the chamber while ensuring safety and control accuracy. The steps cover initial setup, parameter configuration, and routine verification.
Required Equipment: Lifting equipment (e.g., forklift or pallet jack), Dedicated AC power outlet (220 V, 50 Hz, 2300 W capacity)
- Unpack and Position Chamber
Unpack the chamber and use lifting equipment to position it upright on a level surface with adequate clearance for air circulation and service access. - Connect Power Supply
Connect the chamber to the specified AC power supply using a dedicated outlet, and ensure the power cord is securely plugged in. - Set Temperature and Humidity
Set the desired temperature and humidity values on the microcomputer controller, and press the start button to begin conditioning. - Test Over-Temperature Protection
Test the over-temperature protection system by initiating a simulated alarm or checking the status indicator to confirm it is functional. - Load Samples
Place samples onto the removable shelves, ensuring they do not obstruct the air circulation or block the side test port. - Monitor Stability
Close the chamber door and monitor the displayed temperature and humidity readings for stability before starting the test program. - Perform Routine Maintenance
Perform routine maintenance after each use by cleaning the stainless steel interior with a non-abrasive cleaner and checking the drain for blockages.
What is the temperature uniformity specification for the LHS-250HC-II at low versus high temperature setpoints?
The chamber achieves ±0.5°C uniformity at high temperature and ±1.0°C at low temperature, as stated in the technical specifications. This difference is typical for environmental chambers and should be considered when selecting setpoints for sensitive tests.
Can the Atomfair LHS-250HC-II be integrated with external data acquisition systems for real-time monitoring?
Yes, the chamber offers optional RS232/485 communication interface and software, as well as an embedded printer for data output. These options allow integration with external monitoring and logging systems, though they must be specified at the time of ordering.
What are the installation requirements for the 250L constant temperature and humidity chamber regarding power supply and space?
The chamber requires a 2300W power supply at AC 220V, 50Hz, and operates in a working environment of 5-35°C. The external dimensions are 740 x 900 x 1580 mm, so sufficient clearance for air circulation and access to the side test port, drain, and controller should be planned.
The 250 L constant temperature and humidity chamber (AF-LE-E-LHPR-0250-2250) provides microcomputer-based balancing control for stable humidity from 40% to 95%RH and temperature from 10°C to 70°C, with an imported compressor and humidity sensor supporting long-term reliability in biotech, materials, and stability testing applications.
Positive
- Balancing humidity-temperature control: Microcomputer balancing control logic improves stability for qualification, conditioned storage, and repeatable environmental testing, reducing drift in humidity-sensitive incubation and stability studies.
- Imported compressor and sensor: The use of an imported compressor, circulation fan, and humidity sensor supports dependable long-term performance and consistent humidity readout across extended laboratory schedules.
Trade-offs
- Humidity range limited to 40-95%RH: The chamber cannot achieve humidity below 40%RH, restricting its use in applications requiring very low humidity conditions such as desiccation testing or dry storage.
- Specific power and environment requirements: The unit requires a 2300 W, AC 220 V, 50 Hz supply and an ambient operating range of +5°C to 35°C, which may limit installation flexibility in labs with different electrical standards or uncontrolled temperature environments.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).