Professional Constant Temperature and Humidity Chamber, 150 L,with Printer
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The chamber requires a stable working environment between 5°C and 35°C and a dedicated AC 220 V, 50 Hz power supply rated at 2100 W. Installation space must accommodate the external dimensions of 690 x 800 x 1430 mm with accessible air inlets and service points.
- Working Environment Temperature: Operate the chamber only within an ambient temperature range of 5°C to 35°C to ensure proper performance.
- Power Supply: Connect the chamber to a dedicated AC 220 V, 50 Hz power supply capable of delivering 2100 W.
- Installation Space: Allocate a floor area of at least 690 x 800 mm and a height of at least 1430 mm for the chamber body.
- Accessibility: Maintain clear access to air inlets, test ports, shelving, drain areas, doors, and controller surfaces for cleaning and maintenance.
- Transport Orientation: Keep the packed chamber upright at all times and use suitable lifting equipment during unloading and positioning.
Unpack the chamber in the designated installation area ensuring proper orientation and clearance. Connect the power supply and verify environmental conditions before initial operation.
Required Equipment: Lifting equipment
- Confirm installation space
Confirm the installation space meets the external dimensions of 690 x 800 x 1430 mm. - Verify working environment
Verify that the ambient temperature is between 5°C and 35°C. - Prepare power supply
Prepare the specified AC 220 V, 50 Hz power supply rated at 2100 W. - Unpack and position chamber
Unpack the chamber using suitable lifting equipment, keeping it upright during movement. - Ensure service point accessibility
Ensure air inlets, test ports, shelving, drain areas, doors, and controller surfaces are accessible after positioning.
What causes the difference in temperature fluctuation between high and low temperature ranges in the LHS-150HC-II constant temperature and humidity chamber?
The temperature fluctuation specification is ±0.5°C at high temperature and ±1°C at low temperature, as stated in the technical data for the LHS-150HC-II model. The chamber uses a microcomputer balancing temperature-humidity controller, but the source does not explain the underlying cause of the difference; the specified values are provided for both high and low ranges.
Can the LHS-150HC-II chamber be used for low-humidity testing below 40%RH?
No, the humidity control range is 40%RH to 95%RH. The chamber does not provide dehumidification below 40%RH. For applications requiring lower humidity, optional accessories or a different model configuration may be needed.
What are the electrical and installation requirements for the Atomfair LHS-150HC-II constant temperature and humidity chamber?
The chamber requires a 220V AC, 50Hz power supply with a total power consumption of 2100W. Installation space must accommodate external dimensions of 690 x 800 x 1430 mm. The working environment should be maintained at +5 to 35°C. Ensure proper ventilation and access for cleaning and maintenance as per the handling instructions.
The Atomfair LHPR-0150-2150 (model LHS-150HC-II) is a 150L constant temperature and humidity chamber with microcomputer balancing control, imported compressor, fan, and humidity sensor, and a mirror-finish stainless steel interior. It covers 10–70°C and 40–95%RH with temperature uniformity of ±0.5°C (high) to ±1°C (low) and humidity deviation of ±3%RH, making it suitable for industrial research, biotechnology, and stability testing, though it requires a 220V/50Hz, 2100W power supply and a 5–35°C ambient environment.
Positive
- Balancing temperature-humidity control: Microcomputer balancing control logic improves stability for qualification, conditioned storage, and repeatable environmental testing, supporting humidity-sensitive incubation and stability studies.
- Imported compressor and sensor components: Imported compressor, circulation fan, and humidity sensor provide dependable performance across long laboratory schedules, enhancing reliability for continuous operation.
Trade-offs
- Specific power and ambient requirements: Requires AC 220V, 50Hz, 2100W power supply and a working environment of +5 to 35°C, limiting deployment flexibility in labs with non-standard electrical infrastructure or uncontrolled ambient conditions.
- Moderate humidity and temperature tolerances: Humidity deviation of ±3%RH and temperature uniformity of ±0.5 to ±1°C may not meet the tighter tolerances required for some pharmaceutical or material testing protocols.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).