Water-Jacket Incubator 50 L 65 °C AF-WJIN-050N ATOMFAIR®

$1,150.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

50 L water-jacket incubator with programmable LCD control, RT + 5 to 65 °C range, 450 W power, and 0.1 °C resolution for culture workflows. Order now.

SKU: AF-LE-E-WJIN-0050-50N0
Category:
Brands:

50 L Programmable Controller Water-Jacket Constant Temperature Incubator
Research-grade laboratory product
Product Overview

50 L Programmable Controller Water-Jacket Constant Temperature Incubator is designed for constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred. Water-jacket heating, stable holdover after power interruption, and glass inner door observation for constant temperature laboratory work. The configuration provides RT + 5 to 65 °C, 450 W rated power, a working chamber of 350 × 350 × 410 mm (W × D × H), and external dimensions of 500 × 500 × 700 mm (W × D × H).

The control and chamber design support practical laboratory operation: Standard controller or programmable LCD controller in N variants. laboratory chamber construction

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include LCD or programmable controller; printer; U-disk data storage; RS485 interface and communication software; UV sterilization; independent over-temperature controller.

This equipment is suited to laboratories that need constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-WJIN-050N
Product Family Water-Jacket Constant Temperature Incubator
Configuration 50 L Programmable Controller
Rated Operating Power 450 W
Working Chamber Size 350 × 350 × 410 mm (W × D × H)
Overall Dimensions 500 × 500 × 700 mm (W × D × H)
Model Configuration Programmable LCD controller
Heating Method Water-jacket heating
Temperature Control Range RT + 5 to 65 °C
Temperature Resolution / Fluctuation 0.1 °C / ±0.3 °C
Temperature Uniformity ±0.5 °C at 37 °C
Working Ambient Temperature +5 to +35 °C
Timing Range 0 to 5999 min
Power Supply AC 220 V, 50 Hz
Controller Options Standard controller or programmable LCD controller in N variants
Optional Accessories and Functions LCD or programmable controller; printer; U-disk data storage; RS485 interface and communication software; UV sterilization; independent over-temperature controller
Performance Features
  • Water-jacket heating supports stable chamber temperature and better thermal holdover during power interruption according to the product design. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • A glass inner door supports observation, and opening the door pauses operation and cuts heating and circulation fan activity. This helps balance temperature uniformity with sample protection during constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred.
  • Automatic fan speed control adjusts airflow when the chamber reaches the set temperature. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • N variants include multi-step programmable control for more complex incubation processes. This supports controlled, repeatable operation for constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred.
  • Optional UV sterilization, automatic water filling, printer, U-disk export, and communication interface are listed for this family. This supports chamber hygiene and contamination-control routines for constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred.
  • Alarm functions cover high temperature, over-temperature, low water, and extended door opening conditions. This helps operators identify abnormal conditions during unattended or extended constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred.
APPLICATION SCOPE: Suitable for constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 500 × 500 × 700 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: LCD or programmable controller; printer; U-disk data storage; RS485 interface and communication software; UV sterilization; independent over-temperature controller. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator requires a stable ambient environment of +5 to +35 °C and a dedicated AC 220 V, 50 Hz power supply. Water-jacket operation mandates maintaining adequate water levels to prevent low-water alarms and ensure thermal stability.

  • Environmental and Power Requirements: Operate only within the specified ambient temperature range and connect to the rated power supply to ensure safe and accurate temperature control.
  • Water Level Maintenance: Maintain the water jacket at the required level to prevent low-water alarm conditions and ensure uniform heat transfer.
  • Door Operation and Thermal Stability: Minimize door openings, as opening the door pauses heating and fan operation, which can temporarily affect temperature uniformity.
  • Over-Temperature Protection: Verify that the independent over-temperature controller is correctly set to prevent thermal runaway during unattended operation.

This procedure covers initial setup, water filling, and routine operation to ensure safe and reliable incubation. Follow each step in sequence to avoid equipment damage or sample loss.

Required Equipment: Distilled or deionized water, Power supply cord, Leveling feet or spirit level

  1. Position and Level the Incubator
    Place the incubator on a stable, level surface with adequate clearance for ventilation and access to the power cord.
  2. Fill the Water Jacket
    Fill the water jacket with distilled or deionized water to the indicated level, ensuring the water level is above the heating element but below the chamber floor.
  3. Connect to Power
    Plug the power cord into a grounded AC 220 V, 50 Hz outlet that matches the rated power requirement.
  4. Set the Temperature
    Set the desired incubation temperature using the controller, ensuring it is within the range of RT +5 to 65 °C.
  5. Allow Temperature Stabilization
    Allow the chamber to reach the set temperature and stabilize for at least 30 minutes before loading samples.
  6. Load Samples and Monitor
    Place samples inside, close the door securely, and monitor the temperature display to confirm stability.
  7. Respond to Alarms
    If an alarm sounds, check the display for the alarm type (e.g., low water, over-temperature) and take corrective action immediately.

How does the water-jacket heating method affect temperature uniformity and recovery after door opening compared to air-jacket incubators?

The water-jacket design provides stable chamber temperature and better thermal holdover during power interruption. The glass inner door pauses operation and cuts heating/fan when opened, helping balance uniformity with sample protection. Temperature uniformity is ±0.5°C at 37°C, with fluctuation ±0.3°C, supporting reliable incubation.

Can this incubator be integrated with external data logging or monitoring systems?

Yes, optional RS485 interface and communication software are available for this model. Additionally, optional U-disk data storage and printer connections allow data export. The programmable LCD controller supports multi-step control for repeatable workflows.

What are the essential installation requirements and maintenance considerations for this water-jacket incubator?

The incubator requires AC 220V, 50Hz power supply and clearance for external dimensions of 500×500×700 mm. The water-jacket needs periodic water level monitoring; the unit includes a low water alarm. Optional automatic water filling and UV sterilization are available to support hygiene and reduce manual intervention.

The 50 L Programmable Controller Water-Jacket Constant Temperature Incubator (model AF-WJIN-050N) provides water-jacket thermal stability with ±0.3°C fluctuation and ±0.5°C uniformity at 37°C, supporting repeatable incubation workflows. Its programmable LCD controller enables multi-step temperature programs, while the glass inner door and automatic fan speed control balance observation access with temperature recovery.

Positive

  • Water-jacket thermal holdover: Water-jacket heating provides stable chamber temperature and better thermal holdover during power interruption, supporting sample protection and reliable operation.
  • Multi-step programmable control: N variants include multi-step programmable control for complex incubation processes, enabling controlled, repeatable operation for constant temperature workflows.

Trade-offs

  • Limited temperature range: Temperature control range is RT + 5 to 65 °C, which restricts use to moderate-temperature incubation and cannot support high-temperature applications above 65 °C.
  • Ambient temperature dependency: Requires working ambient temperature of +5 to +35 °C; operation outside this range may require additional HVAC infrastructure to maintain specified performance.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).