Water-Jacket Incubator 50 L, RT + 5 to 65 °C ATOMFAIR®

$950.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

50 L water-jacket incubator with RT + 5 to 65 °C range, 450 W power, ±0.3 °C fluctuation and 350 × 350 × 410 mm chamber. Order now.

SKU: AF-LE-E-WJIN-0050-9050
Category:
Brands:

50 L Standard Controller Water-Jacket Constant Temperature Incubator
Research-grade laboratory product
Product Overview

50 L Standard Controller Water-Jacket Constant Temperature Incubator is designed for constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred. Water-jacket heating, stable holdover after power interruption, and glass inner door observation for constant temperature laboratory work. The configuration provides RT + 5 to 65 °C, 450 W rated power, a working chamber of 350 × 350 × 410 mm (W × D × H), and external dimensions of 500 × 500 × 700 mm (W × D × H).

The control and chamber design support practical laboratory operation: Standard controller or programmable LCD controller in N variants. laboratory chamber construction

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include LCD or programmable controller; printer; U-disk data storage; RS485 interface and communication software; UV sterilization; independent over-temperature controller.

This equipment is suited to laboratories that need constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-WJIN-050A
Product Family Water-Jacket Constant Temperature Incubator
Configuration 50 L Standard Controller
Rated Operating Power 450 W
Working Chamber Size 350 × 350 × 410 mm (W × D × H)
Overall Dimensions 500 × 500 × 700 mm (W × D × H)
Model Configuration Standard controller
Heating Method Water-jacket heating
Temperature Control Range RT + 5 to 65 °C
Temperature Resolution / Fluctuation 0.1 °C / ±0.3 °C
Temperature Uniformity ±0.5 °C at 37 °C
Working Ambient Temperature +5 to +35 °C
Timing Range 0 to 5999 min
Power Supply AC 220 V, 50 Hz
Controller Options Standard controller or programmable LCD controller in N variants
Optional Accessories and Functions LCD or programmable controller; printer; U-disk data storage; RS485 interface and communication software; UV sterilization; independent over-temperature controller
Performance Features
  • Water-jacket heating supports stable chamber temperature and better thermal holdover during power interruption according to the product design. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • A glass inner door supports observation, and opening the door pauses operation and cuts heating and circulation fan activity. This helps balance temperature uniformity with sample protection during constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred.
  • Automatic fan speed control adjusts airflow when the chamber reaches the set temperature. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • N variants include multi-step programmable control for more complex incubation processes. This supports controlled, repeatable operation for constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred.
  • Optional UV sterilization, automatic water filling, printer, U-disk export, and communication interface are listed for this family. This supports chamber hygiene and contamination-control routines for constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred.
  • Alarm functions cover high temperature, over-temperature, low water, and extended door opening conditions. This helps operators identify abnormal conditions during unattended or extended constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred.
APPLICATION SCOPE: Suitable for constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 500 × 500 × 700 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: LCD or programmable controller; printer; U-disk data storage; RS485 interface and communication software; UV sterilization; independent over-temperature controller. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator requires a controlled ambient temperature of +5 to +35 °C and a dedicated AC 220 V, 50 Hz power supply. Water-jacket heating necessitates maintaining adequate water levels and avoiding extended door openings to prevent temperature fluctuations.

  • Ambient Temperature Requirement: Operate within ambient temperature +5 to +35 °C to maintain specified temperature control.
  • Power Supply Constraint: Connect to AC 220 V, 50 Hz grounded outlet only.
  • Water Level Maintenance: Maintain water jacket level; low water alarm indicates need for refill.
  • Door Operation Constraint: Opening the door pauses heating and fan; minimize door open duration to preserve temperature uniformity.
  • Over-Temperature Protection: Built-in alarms and optional independent over-temperature controller prevent exceeding safe temperature limits.

How does the water-jacket design and automatic pause on door opening affect temperature uniformity and recovery time during frequent sample observation?

The water-jacket design provides thermal mass for stable temperature holdover during power interruption, but opening the glass inner door pauses heating and fan activity to protect samples. This means that during observation, the chamber temperature may temporarily deviate from setpoint. The automatic fan speed control and water-jacket thermal inertia help minimize temperature fluctuation, but the temperature recovery time depends on ambient conditions and door-open duration. The specifications show temperature uniformity of ±0.5°C at 37°C and fluctuation of ±0.3°C, indicating good stability under normal operation.

What data logging and communication options are available for the 50 L water-jacket incubator?

The incubator offers optional RS485 interface with communication software, printer connectivity, and U-disk data storage for real-time monitoring and data export. These options allow integration with laboratory information systems and remote data logging. The standard controller supports timing from 0 to 5999 min, and the programmable LCD controller (N variant) enables multi-step incubation profiles.

What water quality and maintenance considerations are important for the water-jacket incubator to ensure reliable operation?

The water-jacket requires clean water to prevent scale buildup and microbial growth. The incubator features a low-water alarm to alert users when water level is insufficient. An optional automatic water filling system simplifies maintenance. For detailed maintenance intervals and water quality recommendations, refer to the product manual. The optional UV sterilization accessory helps maintain chamber hygiene for contamination-sensitive workflows.

The 50 L Standard Controller Water-Jacket Constant Temperature Incubator (AF-WJIN-050A) provides water-jacket thermal stability with ±0.3 °C fluctuation and ±0.5 °C uniformity at 37 °C, a glass inner door that pauses heating and fan on opening, and a rated power of 450 W. Its operating ambient range of +5 to +35 °C and requirement for AC 220 V, 50 Hz power supply impose specific installation conditions, while optional accessories such as UV sterilization and independent over-temperature controller are not included in the base configuration.

Positive

  • Water-jacket thermal holdover: Water-jacket heating supports stable chamber temperature and better thermal holdover during power interruption, reducing temperature drift during brief outages.
  • Glass inner door with safety pause: The glass inner door permits visual observation, and opening it automatically pauses heating and fan operation, protecting sample stability and minimizing temperature disturbance.

Trade-offs

  • Restricted ambient temperature range: The incubator requires a working ambient temperature of +5 to +35 °C, limiting deployment in unconditioned or extreme-temperature laboratory environments.
  • Optional features not included in base model: UV sterilization, independent over-temperature controller, and data export interfaces are optional accessories that must be specified at order, adding cost and lead time for full contamination control or remote monitoring.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).