LCD Electric Heated Incubator 160 L AF-EHIN-160B ATOMFAIR®

$1,150.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

160 L LCD electric heated incubator with 600 W power, RT + 5 to 65 °C control, 0.1 °C resolution, ±0.5 °C fluctuation, and forced convection airflow.

SKU: AF-LE-E-EHIN-0160-162B
Category:
Brands:

160 L LCD Controller Electric Heated Constant Temperature Incubator
Research-grade laboratory product
Product Overview

160 L LCD Controller Electric Heated Constant Temperature Incubator is designed for routine constant temperature incubation, culture work, sample holding, and general laboratory heating workflows. Electric heating, forced convection airflow, glass observation door, and optional programmable control for routine incubation work. The configuration provides RT + 5 to 65 °C, 600 W rated power, a working chamber of 500 × 500 × 650 mm (W × D × H), and external dimensions of 790 × 630 × 810 mm (W × D × H).

The control and chamber design support practical laboratory operation: Standard controller or LCD controller in B variants. laboratory chamber construction

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include LCD or programmable controller; printer; U-disk data storage; RS485 interface and communication software; UV sterilization; independent over-temperature controller.

This equipment is suited to laboratories that need routine constant temperature incubation, culture work, sample holding, and general laboratory heating workflows, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-EHIN-160B
Product Family Electric Heated Constant Temperature Incubator
Configuration 160 L LCD Controller
Rated Operating Power 600 W
Working Chamber Size 500 × 500 × 650 mm (W × D × H)
Overall Dimensions 790 × 630 × 810 mm (W × D × H)
Model Configuration LCD controller
Temperature Control Range RT + 5 to 65 °C
Temperature Resolution / Fluctuation 0.1 °C / ±0.5 °C
Working Ambient Temperature +5 to +35 °C
Power Supply AC 220 V, 50 Hz
Controller Options Standard controller or LCD controller in B variants
Airflow Forced convection with adjustable circulation fan
Sterilization Optional UV sterilization
Optional Accessories and Functions LCD or programmable controller; printer; U-disk data storage; RS485 interface and communication software; UV sterilization; independent over-temperature controller
Performance Features
  • This product family uses electric heating and a forced convection airflow system to improve temperature response and chamber uniformity. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • A glass inner door or observation window supports chamber viewing during incubation work. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • Optional programmable control supports multi-step temperature and time programming for selected configurations. This allows the configuration to match documentation, communication and monitoring needs in routine constant temperature incubation, culture work, sample holding, and general laboratory heating workflows.
  • Optional printer, U-disk export, communication interface, and UV sterilization are listed for this family. This supports chamber hygiene and contamination-control routines for routine constant temperature incubation, culture work, sample holding, and general laboratory heating workflows.
  • Independent over-temperature protection is available as an option in the source accessory list. This supports controlled, repeatable operation for routine constant temperature incubation, culture work, sample holding, and general laboratory heating workflows.
  • Higher-capacity vertical models use larger cabinet formats with three or four standard shelves. This supports controlled, repeatable operation for routine constant temperature incubation, culture work, sample holding, and general laboratory heating workflows.
APPLICATION SCOPE: Suitable for routine constant temperature incubation, culture work, sample holding, and general laboratory heating workflows in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 790 × 630 × 810 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: LCD or programmable controller; printer; U-disk data storage; RS485 interface and communication software; UV sterilization; independent over-temperature controller. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This incubator requires a stable AC 220 V, 50 Hz power supply and an ambient temperature of +5 to +35 °C for proper operation. The installation space must accommodate the external dimensions of 790 × 630 × 810 mm and allow access for cleaning and maintenance.

  • Temperature Operating Range: The working chamber temperature is limited to a range of RT +5 to 65 °C.
  • Ambient Temperature Requirement: The ambient temperature must be maintained between +5 and +35 °C.
  • Power Supply Requirement: The incubator must be connected to a single-phase AC 220 V, 50 Hz power supply.
  • Installation Space: The installation area must provide clear space for the 790 × 630 × 810 mm external dimensions.
  • Chamber Access: The chamber interior, sensors, shelves, and filters must remain accessible for cleaning and inspection.

Follow these steps to install and prepare the incubator for operation. Ensure the installation environment meets the required power and space conditions before proceeding.

  1. Confirm Installation Space
    Confirm the installation space meets the required external dimensions of 790 × 630 × 810 mm.
  2. Provide Power Supply
    Provide a dedicated AC 220 V, 50 Hz power supply with proper grounding.
  3. Maintain Chamber Accessibility
    Keep the chamber interior, sensors, shelves, and filters accessible for cleaning and inspection.
  4. Transport Upright
    Transport the packed incubator upright and use suitable lifting equipment to prevent damage.

How does the forced convection airflow system affect temperature uniformity in the AF-EHIN-160B incubator?

The forced convection system with adjustable circulation fan improves temperature response and chamber uniformity, though the source does not provide a quantitative uniformity specification. The temperature fluctuation is ±0.5 °C at stability.

What data logging and communication options are available for the AF-EHIN-160B incubator?

The incubator supports optional RS485 interface and communication software, printer, and U-disk data storage, enabling data export and remote monitoring for routine incubation workflows.

Does the AF-EHIN-160B incubator include independent over-temperature protection?

Yes, an independent over-temperature controller is available as an optional accessory, providing additional safety for temperature-sensitive applications in the laboratory.

This 160L forced-convection incubator provides reliable temperature control from RT+5 to 65°C with ±0.5°C fluctuation, suitable for routine incubation. Its LCD controller and optional programmable features support reproducible workflows, but the narrow temperature range and ambient requirements limit its application to standard laboratory heating tasks.

Positive

  • Forced Convection Airflow System: Electric heating with forced convection and adjustable circulation fan improves temperature uniformity and response across the chamber.
  • Optional Programmable Control: Supports multi-step temperature and time programming for automated incubation protocols, enhancing reproducibility.

Trade-offs

  • Limited Temperature Range: Operates from RT+5 to 65°C, unsuitable for low-temperature incubation or high-temperature sterilization beyond 65°C.
  • Ambient Temperature Dependency: Requires working ambient temperature of +5 to +35°C; performance may degrade outside this range, limiting installation sites.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).