Electric Heated Incubator 80 L 65 °C 400 W ATOMFAIR®

$950.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

80 L electric heated incubator with LCD control, 400 W power, RT + 5 to 65 °C range, 0.1 °C resolution, forced convection, 500 × 400 × 400 mm chamber.

SKU: AF-LE-E-EHIN-0080-082B
Category:
Brands:

80 L LCD Controller Electric Heated Constant Temperature Incubator
Research-grade laboratory product
Product Overview

80 L LCD Controller Electric Heated Constant Temperature Incubator is designed for routine constant temperature incubation, culture work, sample holding, and general laboratory heating workflows. Electric heating, forced convection airflow, glass observation door, and optional programmable control for routine incubation work. The configuration provides RT + 5 to 65 °C, 400 W rated power, a working chamber of 500 × 400 × 400 mm (W × D × H), and external dimensions of 780 × 530 × 560 mm (W × D × H).

The control and chamber design support practical laboratory operation: Standard controller or LCD controller in B variants. laboratory chamber construction

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include LCD or programmable controller; printer; U-disk data storage; RS485 interface and communication software; UV sterilization; independent over-temperature controller.

This equipment is suited to laboratories that need routine constant temperature incubation, culture work, sample holding, and general laboratory heating workflows, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-EHIN-080B
Product Family Electric Heated Constant Temperature Incubator
Configuration 80 L LCD Controller
Rated Operating Power 400 W
Working Chamber Size 500 × 400 × 400 mm (W × D × H)
Overall Dimensions 780 × 530 × 560 mm (W × D × H)
Model Configuration LCD controller
Temperature Control Range RT + 5 to 65 °C
Temperature Resolution / Fluctuation 0.1 °C / ±0.5 °C
Working Ambient Temperature +5 to +35 °C
Power Supply AC 220 V, 50 Hz
Controller Options Standard controller or LCD controller in B variants
Airflow Forced convection with adjustable circulation fan
Sterilization Optional UV sterilization
Optional Accessories and Functions LCD or programmable controller; printer; U-disk data storage; RS485 interface and communication software; UV sterilization; independent over-temperature controller
Performance Features
  • This product family uses electric heating and a forced convection airflow system to improve temperature response and chamber uniformity. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • A glass inner door or observation window supports chamber viewing during incubation work. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • Optional programmable control supports multi-step temperature and time programming for selected configurations. This allows the configuration to match documentation, communication and monitoring needs in routine constant temperature incubation, culture work, sample holding, and general laboratory heating workflows.
  • Optional printer, U-disk export, communication interface, and UV sterilization are listed for this family. This supports chamber hygiene and contamination-control routines for routine constant temperature incubation, culture work, sample holding, and general laboratory heating workflows.
  • Independent over-temperature protection is available as an option in the source accessory list. This supports controlled, repeatable operation for routine constant temperature incubation, culture work, sample holding, and general laboratory heating workflows.
  • Higher-capacity vertical models use larger cabinet formats with three or four standard shelves. This supports controlled, repeatable operation for routine constant temperature incubation, culture work, sample holding, and general laboratory heating workflows.
APPLICATION SCOPE: Suitable for routine constant temperature incubation, culture work, sample holding, and general laboratory heating workflows in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 780 × 530 × 560 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: LCD or programmable controller; printer; U-disk data storage; RS485 interface and communication software; UV sterilization; independent over-temperature controller. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This incubator requires a stable AC 220V, 50Hz power supply and an ambient temperature between +5 and +35°C for safe operation. During transport, the unit must be kept upright and protected from impact to prevent internal damage.

  • Power Supply Requirement: Connect the incubator only to a grounded AC 220V, 50Hz electrical outlet.
  • Ambient Temperature Limit: Operate the incubator within an ambient temperature range of +5 to +35°C to avoid overheating or instability.
  • Over-Temperature Protection: Install the optional independent over-temperature controller to prevent runaway heating if the primary control fails.
  • Transport Orientation: Keep the packed incubator upright during transport to prevent damage to internal components.

Why is the minimum operating temperature of the 80 L LCD controller incubator limited to RT+5°C?

The incubator uses electric heating only and has no active refrigeration system, so the chamber temperature cannot be set below ambient plus 5°C. The forced convection airflow distributes heat but does not provide cooling, and the specified temperature control range is RT+5 to 65°C with a resolution of 0.1°C and fluctuation of ±0.5°C.

Can the 80 L LCD controller incubator be integrated with external data logging systems?

Yes, if the optional RS485 interface and communication software are selected, the incubator can be connected to a computer for remote monitoring and data logging. Additionally, U-disk data storage is available as an optional accessory for direct export of logged data. These options are listed in the product's optional accessories and functions.

What over-temperature protection is available for the 80 L LCD controller incubator?

An independent over-temperature controller is available as an optional accessory. This provides an additional safety mechanism that can shut down the heater if the chamber temperature exceeds a set limit, independent of the main controller. It is not standard but can be ordered to enhance safety for sensitive applications.

The 80 L LCD controller incubator provides forced convection and electric heating for routine incubation with optional UV sterilization and over-temperature protection, but its limited temperature range (RT+5 to 65°C) and specific power requirement (220V/50Hz) may constrain deployment in some labs.

Positive

  • Forced convection airflow uniformity: Electric heating combined with a forced convection airflow system improves temperature response and chamber uniformity, supporting repeatable incubation conditions.
  • Optional UV sterilization and over-temperature protection: Available optional UV sterilization supports chamber hygiene, while an independent over-temperature controller provides added safety for controlled operation.

Trade-offs

  • Limited temperature range: The operating range of RT+5 to 65°C restricts use to low-temperature incubation; higher-temperature applications require alternative equipment.
  • Specific power supply requirement: The incubator requires AC 220 V, 50 Hz, which may necessitate step-down transformers or power adapters in regions with 110 V or 60 Hz mains.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).