60 L Water-Jacket Standard CO2 Incubator 500 W ATOMFAIR®

$7,500.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

60 L water-jacket CO2 incubator with 500 W power, RT + 3 to 55 °C control, 0-20% CO2 range, touchscreen records, 2 shelves. Order now.

SKU: AF-LE-E-RHRW-0060-60RT
Category:
Brands:

60 L Water-Jacket Standard Sterilization CO2 Incubator, High-End Touchscreen Series
Research-grade laboratory product
Product Overview

60 L Water-Jacket Standard Sterilization CO2 Incubator, High-End Touchscreen Series is designed for advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows. Touchscreen trend charts, CO2 control with optional O2 monitoring, and sterilization variants for advanced culture workflows. The configuration provides RT + 3 to 55 °C, 500 W rated power, a working chamber of 380 × 290 × 550 mm (W × D × H), and external dimensions of 534 × 530 × 790 mm (W × D × H).

The control and chamber design support practical laboratory operation: Large touchscreen interface with curve display and record review. laboratory chamber construction The model includes 2 shelves.

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include Zirconia O2 control; humidity display; wireless alarm; account permissions; external temperature and CO2 monitoring; automatic cylinder switching.

This equipment is suited to laboratories that need advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-CO2H-060W
Product Family CO2 Incubator, High-End Touchscreen Series
Configuration 60 L Water-Jacket Standard Sterilization
Rated Operating Power 500 W
Working Chamber Size 380 × 290 × 550 mm (W × D × H)
Overall Dimensions 534 × 530 × 790 mm (W × D × H)
Shelf Configuration 2 shelves
Power Supply AC 220 V, 50 Hz
Temperature Control Range RT + 3 to 55 °C
Working Ambient Temperature +5 to +30 °C
Temperature Uniformity ±0.3 °C at 37 °C
Temperature Stability ±0.1 °C
CO2 Control Range 0 to 20%
CO2 Control Accuracy ±0.1% with infrared sensor
CO2 Recovery Time No more than 3 minutes to recover to 5% after a 30-second door opening
O2 Option Optional zirconia O2 control from 1% to 90%
Relative Humidity Natural evaporation, 90% or higher, with optional humidity display
Controller Large touchscreen interface with curve display and record review
Optional Accessories and Functions Zirconia O2 control; humidity display; wireless alarm; account permissions; external temperature and CO2 monitoring; automatic cylinder switching
Performance Features
  • The touchscreen controller supports trend curves, alarm review, and 72-hour running record lookup according to the product design. This makes real-time parameter review and routine operation easier in advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • Infrared CO2 sensing and optional O2 control support advanced gas-environment culture workflows. This allows the configuration to match documentation, communication and monitoring needs in advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • RHP models use 90 °C high-temperature and high-humidity sterilization, while selected RWP(90) models add UV and 90 °C sterilization support. This supports chamber hygiene and contamination-control routines for advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • An environmental temperature monitoring system and heated outer door support stable chamber control and reduced condensation. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • Optional wireless alarm, account permissions, external temperature and CO2 monitoring, and automatic cylinder switching are listed. This helps operators identify abnormal conditions during unattended or extended advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • Alarm coverage includes power failure, CO2 deviation, door opening, and multiple temperature sensor conditions. This helps operators identify abnormal conditions during unattended or extended advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
APPLICATION SCOPE: Suitable for advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 534 × 530 × 790 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: Zirconia O2 control; humidity display; wireless alarm; account permissions; external temperature and CO2 monitoring; automatic cylinder switching. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

Confirm the available space and power supply before installation. Keep all chamber components accessible for cleaning and inspection.

  • Space and Power Requirements: Confirm the external dimensions of 534 × 530 × 790 mm and the power supply specification of AC 220 V, 50 Hz before installation.
  • Transport Handling: Keep the packed unit upright and use suitable lifting equipment during transport to prevent damage.
  • Maintenance Accessibility: Keep the chamber, sensors, shelves, filters, doors, test ports, and control interfaces accessible for cleaning, inspection, and operation.
  • Optional Accessory Selection: Select optional accessories and functions according to the required workflow before operation.

Confirm the installation space and power supply before unpacking the incubator. During transport, keep the unit upright and use suitable lifting equipment to avoid damage.

Required Equipment: Suitable lifting equipment

  1. Confirm Space and Power
    Confirm that the installation space accommodates the external dimensions of 534 × 530 × 790 mm and that the power supply matches AC 220 V, 50 Hz.
  2. Transport the Unit
    Transport the packed incubator to the installation site, keeping it upright and using suitable lifting equipment.
  3. Verify Accessibility
    After unpacking, verify that the chamber, sensors, shelves, filters, doors, test ports, and control interfaces are accessible for cleaning, inspection, and operation.

What is the CO2 recovery time after a door opening, and how does the infrared sensor maintain accuracy?

The CO2 recovery time is no more than 3 minutes to return to 5% after a 30-second door opening. The infrared CO2 sensor provides control accuracy of ±0.1% over a 0–20% range, ensuring stable gas conditions during advanced cell culture protocols.

Can the 60 L water-jacket CO2 incubator be configured for low-oxygen or hypoxic cell culture?

Yes, the incubator supports an optional zirconia O2 control module that enables O2 regulation from 1% to 90%, allowing hypoxic or hyperoxic culture conditions. Other optional accessories include humidity display, wireless alarm, account permissions, external monitoring, and automatic cylinder switching.

What are the critical installation requirements, including space and power supply, for the 60 L water-jacket CO2 incubator?

The incubator requires external dimensions of 534 × 530 × 790 mm (W × D × H) and a power supply of AC 220 V, 50 Hz with a rated power of 500 W. The unit should be installed with access to the chamber, sensors, and controls for cleaning and maintenance, and transported upright with reinforced packaging.

The 60 L water-jacket CO2 incubator offers fast CO2 recovery, high-precision temperature and CO2 control, and optional O2 management, but relies on natural evaporation for humidity and requires a restricted ambient temperature range.

Positive

  • Fast CO2 recovery after door opening: CO2 recovery time no more than 3 minutes to recover to 5% after a 30-second door opening, reducing gas consumption and maintaining stable culture conditions.
  • High-precision temperature and CO2 control: Temperature uniformity ±0.3°C at 37°C and CO2 control accuracy ±0.1% with infrared sensor ensure reproducible incubation environments.

Trade-offs

  • No active humidity control: Relative humidity is achieved via natural evaporation and is not actively controlled; only optional humidity display is available, limiting applications requiring precise humidity regulation.
  • Restricted ambient temperature range: Operating ambient temperature must be between +5°C and +30°C, which may constrain placement in non-air-conditioned laboratories or hot environments.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).