CO2 Incubator 240 L Gas-Jacket UV Sterilization ATOMFAIR®

$7,500.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 240 L gas-jacket UV sterilization CO2 incubator with IR sensing, 0-20% CO2 control, ±0.1% accuracy, 950 W power and 3 shelves. Order now.

SKU: AF-LE-E-CHCW-0240-24CU
Category:
Brands:

240 L Gas-Jacket UV Sterilization CO2 Incubator, IR Sensor Economy Series
Research-grade laboratory product
Product Overview

240 L Gas-Jacket UV Sterilization CO2 Incubator, IR Sensor Economy Series is designed for cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows. Infrared CO2 control with gas-jacket or water-jacket chamber options and sterilization variants for different culture workflows. The configuration provides RT + 5 to 55 °C, 950 W rated power, a working chamber of 600 × 630 × 670 mm (W × D × H), and external dimensions of 788 × 837 × 940 mm (W × D × H).

The control and chamber design support practical laboratory operation: laboratory controller. laboratory chamber construction The model includes 3 shelves.

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include Humidity display; printer; communication interface; gas regulator; optional HEPA filtration.

This equipment is suited to laboratories that need cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-CO2E-240G
Product Family CO2 Incubator, IR Sensor Economy Series
Configuration 240 L Gas-Jacket UV Sterilization
Rated Operating Power 950 W
Working Chamber Size 600 × 630 × 670 mm (W × D × H)
Overall Dimensions 788 × 837 × 940 mm (W × D × H)
Shelf Configuration 3 shelves
Power Supply AC 220 V, 50 Hz
Temperature Control Range RT + 5 to 55 °C
Working Ambient Temperature +5 to +30 °C
CO2 Control Range 0 to 20%
CO2 Control Accuracy ±0.1% with infrared sensor
CO2 Recovery Time No more than 3 minutes to recover to 5% after a 30-second door opening
Temperature Recovery Time No more than 8 minutes to recover to 37 °C after a 30-second door opening
Relative Humidity Natural evaporation, 90% or higher
Optional Accessories and Functions Humidity display; printer; communication interface; gas regulator; optional HEPA filtration
Performance Features
  • Infrared CO2 sensing supports stable CO2 control in routine culture workflows. This supports controlled, repeatable operation for cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
  • Gas-jacket, water-jacket, UV sterilization, and 90 °C sterilization variants are available within this product family. This supports chamber hygiene and contamination-control routines for cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
  • Microbial filtration at the gas inlet helps reduce contamination risk in the chamber atmosphere. This helps maintain cleaner chamber air for contamination-sensitive cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
  • Door heating, circulation control, and optional HEPA filtration support cleaner culture operation. This helps maintain cleaner chamber air for contamination-sensitive cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
  • Optional humidity display, printer, communication interface, and gas regulator accessories are listed. This allows the configuration to match documentation, communication and monitoring needs in cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
  • The family is described as a value-focused upgrade line for routine non-medical laboratory use. This supports controlled, repeatable operation for cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
APPLICATION SCOPE: Suitable for cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 788 × 837 × 940 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: Humidity display; printer; communication interface; gas regulator; optional HEPA filtration. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator requires a dedicated AC 220V 50Hz power supply and a controlled ambient temperature between +5°C and +30°C. Ensure adequate space for the 788x837x940 mm external dimensions and maintain chamber access for cleaning, inspection, and maintenance.

  • Power Supply: Connect the unit to a grounded AC 220V 50Hz power outlet with a rated capacity of at least 950 W.
  • Ambient Temperature: Operate the incubator only within an ambient temperature range of +5°C to +30°C to avoid temperature control instability.
  • Installation Clearance: Provide sufficient clearance around the 788x837x940 mm external dimensions for ventilation and door opening as per standard laboratory equipment installation.
  • Transport Orientation: Keep the packed unit upright during transport and use suitable lifting equipment to prevent damage to the gas-jacket and internal components.
  • Chamber Accessibility: Keep the chamber, sensors, shelves, filters, doors, test ports, and control interfaces accessible for routine cleaning, inspection, and operation.

How quickly does the CO2 level recover after a 30-second door opening?

The CO2 recovery time is no more than 3 minutes to return to 5% CO2 after a 30-second door opening, as specified in the technical specifications. This rapid recovery is enabled by the infrared CO2 sensor and gas-jacket design, minimizing disruption to cell culture conditions.

Can this CO2 incubator be equipped with a humidity display or communication interface for external monitoring?

Yes, the incubator supports optional accessories including a humidity display, printer, communication interface, and gas regulator. These options allow integration with external data logging or monitoring systems, though they are not included as standard and must be selected at order configuration.

What are the power supply and ambient temperature requirements for installation?

The unit requires a single-phase AC 220 V, 50 Hz power supply and an ambient temperature range of +5 to +30 °C. The rated operating power is 950 W. Installation space must accommodate the external dimensions of 788 × 837 × 940 mm (W × D × H) and allow access for cleaning, inspection, and operation.

The 240 L Gas-Jacket UV Sterilization CO2 Incubator (AF-CO2E-240G) provides infrared CO2 sensing with fast recovery and integrated contamination control, but requires stable ambient conditions and lacks active humidity regulation.

Positive

  • Infrared CO2 Sensing with Fast Recovery: Infrared CO2 sensor provides ±0.1% control accuracy and recovers to 5% CO2 within 3 minutes after a 30-second door opening, enabling stable and repeatable culture conditions.
  • Integrated Contamination Control Features: Gas-jacket design with UV sterilization, microbial gas inlet filtration, and optional HEPA filtration support chamber hygiene and reduce contamination risk in sensitive cell culture workflows.

Trade-offs

  • Ambient Temperature Dependency: The incubator requires a working ambient temperature range of +5 to +30°C; deviations may affect temperature control performance, limiting placement in unconditioned or extreme environments.
  • No Active Humidity Control: Relative humidity is achieved via natural evaporation (≥90% RH) without active regulation; optional humidity display is available but not standard, requiring external humidification or monitoring for precise humidity-dependent protocols.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).