Semiconductor Cooling Low-Temperature Incubator 250L ATOMFAIR®

$7,500.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

250 L semiconductor cooling low-temperature incubator with 5 to 65 °C control, ±0.2 °C accuracy, 600 W cooling and 700 W heating. ATOMFAIR®.

SKU: AF-LE-E-SCLT-0250-C250
Category:
Brands:

250 L Semiconductor Cooling Low-Temperature Incubator with Peltier Cooling
Research-grade laboratory product
Product Overview

250 L Semiconductor Cooling Low-Temperature Incubator with Peltier Cooling is designed for low-temperature microorganism cultivation, sample storage, plant cultivation, plant breeding, and routine temperature-controlled laboratory workflows. Peltier semiconductor cooling, touchscreen control, rapid recovery, and adjustable circulation fan settings for low-temperature laboratory use. The configuration provides 5 to 65 °C, Cooling 600 W / heating 700 W rated power, a working chamber of 600 × 510 × 820 mm (W × D × H), and external dimensions of 790 × 745 × 1085 mm (W × D × H).

The control and chamber design support practical laboratory operation: 7-inch intelligent touchscreen controller. 304 stainless-steel inner chamber with adjustable shelves and glass inner door

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include UV sterilization system; printer or RS485 communication interface; USB data export; electronic signature function; smart App control system.

This equipment is suited to laboratories that need low-temperature microorganism cultivation, sample storage, plant cultivation, plant breeding, and routine temperature-controlled laboratory workflows, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-SCLI-250
Product Family Semiconductor Cooling Low-Temperature Incubator
Configuration 250 L
Rated Operating Power Cooling 600 W / heating 700 W
Working Chamber Size 600 × 510 × 820 mm (W × D × H)
Overall Dimensions 790 × 745 × 1085 mm (W × D × H)
Controller 7-inch intelligent touchscreen controller
Temperature Control Range 5 to 65 °C
Temperature Accuracy ±0.2 °C
Temperature Uniformity ±0.5 °C at 37 °C and ±0.5 °C at 25 °C
Temperature Sensor Dual Pt100 sensors
Door Recovery Time No more than 5 minutes after a 30-second door opening at 37 °C
Standard Shelves 2 shelves
Power Supply AC 220 V or 110 V, 50 Hz
Chamber Design 304 stainless-steel inner chamber with adjustable shelves and glass inner door
Optional Accessories and Functions UV sterilization system; printer or RS485 communication interface; USB data export; electronic signature function; smart App control system
Performance Features
  • Peltier semiconductor cooling provides both cooling and heating without compressor-based refrigeration in this product family. This supports efficient low-temperature operation for low-temperature microorganism cultivation, sample storage, plant cultivation, plant breeding, and routine temperature-controlled laboratory workflows.
  • A rapid recovery design restores the working temperature after a 30-second door opening within the stated limit of 5 minutes at 37 °C. This supports controlled, repeatable operation for low-temperature microorganism cultivation, sample storage, plant cultivation, plant breeding, and routine temperature-controlled laboratory workflows.
  • An adjustable circulation fan supports a balance between chamber uniformity and sample protection from excessive airflow. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • Foamed cabinet insulation reduces heat loss and supports stable low-temperature control. This supports controlled, repeatable operation for low-temperature microorganism cultivation, sample storage, plant cultivation, plant breeding, and routine temperature-controlled laboratory workflows.
  • A password lock, USB data export, bilingual interface, and optional electronic signature and App monitoring support recorded operation. This allows the configuration to match documentation, communication and monitoring needs in low-temperature microorganism cultivation, sample storage, plant cultivation, plant breeding, and routine temperature-controlled laboratory workflows.
  • High and low temperature alarms provide audible and visual notification during operation. This helps operators identify abnormal conditions during unattended or extended low-temperature microorganism cultivation, sample storage, plant cultivation, plant breeding, and routine temperature-controlled laboratory workflows.
APPLICATION SCOPE: Suitable for low-temperature microorganism cultivation, sample storage, plant cultivation, plant breeding, and routine temperature-controlled laboratory workflows in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 790 × 745 × 1085 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: UV sterilization system; printer or RS485 communication interface; USB data export; electronic signature function; smart App control system. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator must be installed with adequate clearance for service access and connected to a dedicated power supply matching the rated voltage (220 V or 110 V, 50 Hz). Transport and storage require an upright orientation and the use of suitable lifting equipment to prevent damage to the Peltier cooling system.

  • Power Supply Constraint: Connect the incubator only to a grounded AC power outlet rated for the unit's cooling and heating loads (600 W max cooling, 700 W max heating) and matching the specified voltage (220 V or 110 V, 50 Hz).
  • Transport Orientation: Keep the packed incubator upright during transport and use suitable lifting equipment to avoid shock and damage.
  • Service Access: Maintain access to the chamber, sensors, shelves, filters, doors, test ports, and control interfaces for routine cleaning and inspection.

Confirm that the installation site meets the space and power requirements, then position the unit with full access to all service panels. After transport, connect the power and verify the system is ready for temperature programming.

Required Equipment: Suitable lifting equipment

  1. Transport the Incubator
    Transport the packed incubator upright using suitable lifting equipment to the installation site.
  2. Verify Installation Site
    Confirm the installation space meets the external dimensions (790 × 745 × 1085 mm) and provides the required power supply (AC 220 V or 110 V, 50 Hz).
  3. Ensure Service Access
    Position the incubator so that the chamber, sensors, shelves, filters, doors, and control interfaces remain accessible for cleaning, inspection, and operation.

How does the Peltier semiconductor cooling system affect temperature recovery after door openings compared to compressor-based incubators?

The rapid recovery design restores the working temperature within 5 minutes after a 30-second door opening at 37°C, with temperature uniformity of ±0.5°C at both 37°C and 25°C. The Peltier system provides both cooling and heating without a compressor, enabling efficient low-temperature operation as specified in the technical data.

Can this 250L semiconductor cooling incubator be used for mammalian cell culture requiring CO2 control?

No, this incubator is designed for low-temperature microorganism cultivation, sample storage, plant cultivation, plant breeding, and routine temperature-controlled laboratory workflows. It does not include CO2 injection or control, so it is not suitable for mammalian cell culture requiring a CO2 atmosphere.

What are the electrical and space requirements for installing the Atomfair AF-SCLI-250 Peltier incubator?

The incubator requires AC 220V or 110V, 50Hz power supply and external dimensions of 790 × 745 × 1085 mm (W × D × H). Ensure adequate space for door access, ventilation, and cleaning of the 304 stainless steel chamber, sensors, and filters. Optional accessories such as UV sterilization, RS485, or USB data export may require additional planning.

The 250 L Peltier-cooled incubator (AF-SCLI-250) offers compressor-free temperature control from 5 to 65°C with ±0.2°C accuracy and rapid recovery within 5 minutes after door opening, making it suitable for low-temperature cultivation and storage, but requiring space/power verification and optional accessory selection.

Positive

  • Peltier semiconductor cooling without compressor: Uses Peltier elements for both heating and cooling, eliminating compressor-based refrigeration and enabling efficient low-temperature operation.
  • Rapid temperature recovery after door opening: Restores working temperature within 5 minutes after a 30-second door opening at 37°C, supporting reproducible incubation conditions.

Trade-offs

  • Requires space and power verification before installation: External dimensions of 790×745×1085 mm and specific power supply (AC 220V or 110V, 50 Hz) must be confirmed to ensure proper fit and electrical compatibility.
  • Optional accessories not included in base unit: UV sterilization, printer/RS485, USB data export, electronic signature, and smart App control must be ordered separately, requiring upfront workflow planning.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).