50 L Semiconductor Cooling Low-Temperature Incubator with Peltier Cooling
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The incubator requires a stable AC power supply of 220 V or 110 V at 50 Hz and must be placed in a space accommodating its 540 × 630 × 690 mm external dimensions. Chamber access, sensors, filters, and control interfaces must remain unobstructed for cleaning and inspection.
- Power Supply Requirement: Connect the incubator only to the specified AC 220 V or 110 V, 50 Hz power supply to ensure safe and stable operation.
- Installation Space Requirement: Confirm the available space accommodates the 540 × 630 × 690 mm external dimensions before installation.
- Chamber Accessibility Requirement: Keep the chamber, sensors, shelves, filters, doors, test ports, and control interfaces accessible for routine cleaning, inspection, and operation.
- Transport Orientation Requirement: Keep the packed unit upright during transport and use suitable lifting equipment to prevent impact damage.
Position the incubator in a suitable location with adequate clearance and connect it to the specified power supply. Configure the temperature setpoint and circulation fan settings via the touchscreen controller before loading samples.
Required Equipment: 7-inch intelligent touchscreen controller, Adjustable shelves
- Position the Incubator
Place the incubator on a level surface with sufficient clearance around all sides for ventilation and access. - Connect Power Supply
Connect the power cord to a grounded AC outlet matching the specified voltage (220 V or 110 V, 50 Hz). - Set Temperature Parameters
Use the touchscreen controller to set the desired temperature within the 5 to 65 °C range and confirm the setpoint. - Adjust Circulation Fan Speed
Select the appropriate circulation fan setting on the controller to balance chamber uniformity with sample protection from airflow. - Load Samples into Chamber
Place samples on the adjustable shelves inside the chamber, ensuring they do not obstruct airflow or contact the temperature sensors. - Close Doors and Start Operation
Close the glass inner door and outer door securely, then start the incubation cycle via the touchscreen controller. - Monitor Alarms and Data Logging
Monitor the display for high or low temperature alarms and use USB data export or optional communication interfaces for recorded operation.
How does the adjustable circulation fan affect temperature uniformity and sample protection in the 50 L semiconductor cooling incubator?
The adjustable circulation fan allows balancing chamber uniformity and sample protection from excessive airflow. According to specifications, temperature uniformity is ±0.5 °C at both 37 °C and 25 °C, demonstrating that the fan can be tuned to maintain uniformity while minimizing disturbance to samples. The dual Pt100 sensors and rapid recovery (≤5 minutes after a 30-second door opening at 37 °C) further support controlled conditions.
Can the Atomfair AF-SCLI-050 incubator be integrated into a laboratory monitoring system via RS485 or smart App?
Yes, the incubator supports optional RS485 communication interface, printer connection, and a smart App control system. The 7-inch touchscreen controller also provides USB data export and electronic signature function. These options allow integration with laboratory monitoring systems and data logging, though they must be selected as optional accessories at time of purchase.
What are the power supply and space requirements for installing the 50 L Peltier cooling incubator?
The incubator requires AC 220 V or 110 V, 50 Hz, with cooling 200 W and heating 300 W rated power. External dimensions are 540 × 630 × 690 mm (W × D × H). The unit must be positioned to allow access to the chamber, sensors, shelves, filters, doors, test ports, and control interfaces. Reinforced packaging is used for transport; keep upright and use suitable lifting equipment.
The 50 L Peltier-cooled incubator provides compressor-free cooling and heating with rapid temperature recovery after door openings, making it suitable for low-temperature microbiological and plant cultivation workflows. Its 5–65 °C range and reliance on optional accessories for data logging, UV sterilization, and remote monitoring impose operational constraints that must be reviewed before procurement.
Positive
- Compressor-free Peltier cooling: Eliminates compressor vibration and refrigerant, enabling low-noise, low-maintenance operation suitable for vibration-sensitive applications such as microbiological culture and sample storage.
- Rapid temperature recovery after door opening: Restores setpoint temperature within 5 minutes after a 30-second door opening at 37 °C, minimizing thermal disturbance during sample access and supporting repeatable incubation conditions.
Trade-offs
- Limited temperature range: Operating range of 5 to 65 °C restricts use for high-temperature incubations or deep cold storage; not suitable for applications requiring temperatures below 5 °C or above 65 °C.
- Optional features require separate selection: Key functions such as UV sterilization, printer/RS485 interface, electronic signature, and smart App control are not included by default and must be ordered as optional accessories, adding lead time and cost.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).