4-Face Strong-Light Incubator 600 L AF-GZX600F ATOMFAIR®

$7,000.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

600 L four-sided strong-light incubator with 5–60 °C control, 0–18,000 lux across six levels, 0.1 °C resolution and programmable LCD control. Order now.

SKU: AF-LE-E-GZXF-0600-600F
Category:
Brands:

Four-Sided Strong-Light Incubator, 600 L
Research-grade laboratory product
Product Overview

Four-Sided Strong-Light Incubator, 600 L is a practical chamber for plant growth, tissue culture, seed germination, cultivation, seedling raising, microbial culture and preservation, medicinal-material and building-material testing, insect rearing and quality inspection. It brings together 600 l of usable space, 5 to 60 C and 0 to 18000 lux (6 levels) illumination, so the chamber can keep samples in a steady, repeatable working condition.

The cabinet combines a visible glass inner door, cleanable stainless-steel surfaces and a strong-light layout for demanding growth experiments. The cabinet uses a mirror-finish stainless-steel inner chamber, a tempered-glass inner door, a cold-rolled steel exterior and four-sided strong lighting, with an internal working room of 680 x 800 x 1100 mm and an external footprint of 950 x 1140 x 1920 mm. That combination of chamber size, shell build and liner material makes the unit easier to place, clean and use in routine laboratory work.

The four-sided strong-light layout is suited to experiments that need higher illumination intensity while still using the standard programmable incubation framework. The stated input power is 1300 W, and the timer range is 0 to 9999 min. It is well suited to the day-to-day work listed above, including culture, incubation, climate simulation or illuminated growth tasks, depending on the family.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-GZX600F
Capacity 600 L
Temperature Control Range 5 to 60 C
Temperature Resolution 0.1 C
Temperature Uniformity +/- 1 C
Light Intensity 0 to 18000 Lux (6 levels)
Lighting Faces 4 faces
Controller LCD microcomputer programmable controller
Chamber Material Mirror-finish stainless-steel inner chamber
Exterior Shell Cold-rolled steel shell with electrostatic powder coating
Power / Input 1300 W
Power Supply AC220V 50Hz
Timer Range 0 to 9999 min
Internal Dimensions 680 x 800 x 1100 mm
External Dimensions 950 x 1140 x 1920 mm
Net Weight 265 Kg
Shelves / Trays 2 shelves
Configuration Note Four-sided strong lighting supports high-light cultivation and comparison tests
Performance Features
  • Four-sided strong lighting supports higher-intensity plant-growth experiments. This supports repeatable plant-growth and photoperiod experiments.
  • Programmable temperature and light control helps maintain repeatable experimental conditions. This supports repeatable plant-growth and photoperiod experiments.
  • Mirror-finish stainless-steel surfaces and a glass inner door support observation and cleaning. This helps with cleaning, corrosion resistance and long-term laboratory use.
  • Self-diagnosis, over-temperature self-limiting and power-off memory help protect the chamber during routine use. This helps preserve operation settings after power interruptions.
  • The series uses a clean cabinet structure with removable shelving for easier loading and maintenance. This supports more reliable day-to-day chamber use.
  • High-intensity illumination makes the series suitable for stronger light-demanding samples. This supports repeatable plant-growth and photoperiod experiments.
APPLICATION SCOPE: Suitable for plant growth, tissue culture, seed germination, cultivation, seedling raising, microbial culture and preservation, medicinal-material and building-material testing, insect rearing and quality inspection in universities, laboratories, research institutes and quality-control environments that need controlled chamber performance.
HANDLING: Keep the chamber level, leave enough room for ventilation and confirm the selected shelf and lighting configuration before operation. Every unit is shipped with reinforced packaging for transport safety; keep the unit upright during unloading and positioning.
IMPORTANT NOTICE: When set temperature is 10 C or below, ambient temperature should not exceed 26 C. The page notes no humidity control for this series and indicates performance data are measured at standard no-load test conditions. Any quoted amount refers to the chamber body only and does not include freight. Freight should be confirmed separately according to the delivery destination.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

When the set temperature is 10 °C or below, the ambient temperature must not exceed 26 °C to prevent performance degradation. The chamber lacks humidity control, and performance data are measured under standard no-load test conditions.

  • Set Point Ambient Limit: If the set temperature is 10 °C or below, the ambient temperature must remain at or below 26 °C.

Position the chamber on a level surface with adequate ventilation clearance for safe heat dissipation. Confirm the shelf and lighting configuration before powering on the unit.

Required Equipment: Leveling feet, Shelf supports

  1. Position the chamber
    Place the incubator on a level floor and leave sufficient space around the unit for ventilation.
  2. Install shelves
    Insert the provided shelves into the desired height slots inside the chamber before loading samples.
  3. Confirm lighting configuration
    Verify that the four-sided strong-light system is properly connected and all lamps are seated before starting a program.
  4. Set temperature and light program
    Program the desired temperature and light intensity levels using the front-panel LCD microcomputer controller.
  5. Verify ambient conditions
    Confirm that the ambient temperature does not exceed 26 °C if the set point is 10 °C or below.

What ambient temperature conditions are required when using the Atomfair AF-GZX600F incubator with set temperatures at or below 10°C?

When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C. This is a stated requirement to maintain proper operation; the product does not provide humidity control, and performance data are measured at standard no-load conditions.

How does the power-off memory feature protect experimental settings in the Atomfair incubator during an unexpected power interruption?

The Atomfair AF-GZX600F is equipped with a power-off memory function that automatically preserves operation settings after a power interruption. This ensures that programmed temperature and light cycles are retained without manual re-entry, protecting experimental continuity.

What is the temperature uniformity specification for the Atomfair AF-GZX600F 600L incubator, and how is it measured?

The temperature uniformity is ±1°C across the 600L chamber (internal dimensions 680×800×1100 mm). This specification is measured at standard no-load test conditions. The incubator uses a mirror-finish stainless-steel inner chamber and a programmable LCD controller to maintain stability.

The Four-Sided Strong-Light Incubator (600 L) uses a 4-sided illumination system with up to 18000 lux and programmable temperature control, making it suitable for high-light plant growth experiments, but it requires ambient temperature management when set below 10°C and does not include humidity control.

Positive

  • Four-sided strong-light illumination: The chamber provides illumination from four faces with six intensity levels up to 18000 lux, enabling high-light plant growth and photoperiod experiments with improved uniformity compared to single-sided lighting.
  • Programmable LCD controller with safety features: The microcomputer programmable controller maintains stable temperature and light cycles, while self-diagnosis, over-temperature self-limiting, and power-off memory protect samples and preserve settings after interruptions.

Trade-offs

  • Ambient temperature limit at low set points: When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C, which may require additional climate control in warm laboratory environments.
  • No integrated humidity control: The chamber does not provide humidity regulation, limiting its use for applications requiring controlled moisture levels, such as certain tissue culture or microbial studies.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).