Four-Sided Strong-Light Incubator, 180 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This incubator requires a level surface with adequate ventilation and no humidity control. When set below 10°C, ambient temperature must not exceed 26°C to maintain performance.
- Level Surface Requirement: Place the chamber on a level surface to ensure proper operation.
- Ventilation Clearance: Provide sufficient clearance around the chamber for air circulation.
- Ambient Temperature Limit: When the set temperature is 10°C or below, ambient temperature must not exceed 26°C.
- No Humidity Control: The chamber does not include humidity control functionality.
- Performance Data Conditions: Performance specifications are measured under standard no-load test conditions.
Follow these steps to position, configure, and start the incubator for growth experiments. Proper setup ensures repeatable conditions and prevents equipment damage.
- Position the Chamber
Position the chamber on a level surface. - Provide Ventilation
Leave adequate space around the chamber for ventilation. - Transport the Unit
Keep the unit upright during unloading and transport to the installation site. - Configure Shelves and Lighting
Confirm the shelf and lighting configuration before powering on the chamber. - Verify Ambient Conditions
Verify that ambient temperature does not exceed 26°C when the set temperature is 10°C or below.
What are the light intensity levels and how does the four-sided configuration improve illumination uniformity compared to single-sided lighting?
The incubator provides 0 to 18000 Lux in 6 levels from four sides. The four-sided strong-light layout ensures more uniform illumination across the chamber, reducing shadows and supporting consistent plant growth experiments. The mirror-finish stainless-steel interior also reflects light to enhance distribution.
What are the ambient temperature limitations when operating the AF-GZX180F at low set temperatures?
When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C. The chamber does not include humidity control, so users requiring precise humidity must use additional equipment. The temperature uniformity is ±1°C across the 180L working volume.
What power requirements and safety features does the Four-Sided Strong-Light Incubator have?
The incubator requires a 220V AC 50Hz power supply with a 900W input. Safety features include over-temperature self-limiting, power-off memory to retain settings after power loss, and self-diagnosis. The unit must be placed on a level surface with adequate ventilation, and kept upright during transport.
The Four-Sided Strong-Light Incubator, 180 L (AF-GZX180F) provides a 180 L mirror-finish stainless-steel chamber with four-sided illumination up to 18000 lux across 6 levels, a programmable LCD controller, and a temperature range of 5 to 60 °C with ±1 °C uniformity, making it suitable for high-light plant growth and microbial culture applications.
Positive
- Four-sided strong-light illumination: The 18000 lux maximum intensity from four faces supports high-light-demanding plant growth and photoperiod experiments, enabling uniform light distribution across the 180 L chamber.
- Programmable temperature and light control: The LCD microcomputer controller allows programmable temperature and light cycles, ensuring repeatable experimental conditions for seed germination, tissue culture, and microbial culture.
Trade-offs
- Ambient temperature constraint at low setpoints: When the set temperature is 10 °C or below, the ambient temperature must not exceed 26 °C, limiting placement in unconditioned laboratory spaces during low-temperature operation.
- No humidity control: The chamber lacks integrated humidity regulation, which may require external humidification or dehumidification for applications such as tissue culture or microbial preservation where moisture control is critical.