Top-Light Incubator, 600 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The chamber requires a level installation with adequate ventilation and an ambient environment of 5 to 40 °C with relative humidity below 90%. When the set temperature is 10 °C or below, the ambient temperature must not exceed 26 °C to maintain performance.
- Environmental Limits: Operate the incubator only within the stated ambient temperature and humidity ranges to prevent performance degradation.
- Installation Requirements: Position the unit on a level surface with sufficient clearance for ventilation and keep it upright during unloading and positioning.
- Safety Protections: The self-diagnosis, over-temperature self-limiting, and power-off memory features protect the chamber and preserve settings after power interruptions.
This procedure covers the initial setup and routine operation of the incubator for illuminated incubation tasks. Follow these steps to ensure safe and repeatable chamber performance.
Required Equipment: Leveling tool (e.g., spirit level), Programmable LCD controller
- Position the chamber
Place the incubator on a level, stable surface with adequate clearance for ventilation and access. - Verify ambient conditions
Confirm the room temperature and humidity are within the specified operating range, especially if the set temperature is 10 °C or below. - Configure shelves and lighting
Install the required shelves and confirm the top-light configuration before loading samples. - Set temperature and light program
Use the LCD controller to program the desired temperature, light intensity, and timer settings for the experiment. - Load samples
Place samples inside the chamber, ensuring they do not obstruct airflow or the light source. - Start the incubation cycle
Initiate the programmed cycle and monitor the chamber through the glass door for proper operation. - Monitor and maintain
Periodically check the chamber for any error codes or temperature deviations and clean the stainless-steel surfaces as needed.
What is the ambient temperature requirement when operating the incubator at low set points?
When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C. The general work environment is 5 to 40°C with relative humidity below 90%. This constraint ensures stable temperature control and prevents condensation or overheating of the refrigeration system at low set points.
Can the Top-Light Incubator 600 L support photoperiod experiments with programmable light cycles?
Yes, the incubator features an LCD microcomputer programmable controller that simultaneously manages temperature and light intensity. Illumination is provided from 2 faces (top lighting) with 6 selectable levels from 0 to 10000 lux, and a timer range of 0 to 9999 min, allowing precise photoperiod scheduling for plant-growth and tissue-culture experiments.
What power and installation infrastructure is required for the 600 L incubator?
The unit requires a single-phase AC220V 50Hz power supply with a rated input of 1200 W. Its external footprint is 920 x 955 x 1795 mm, and it weighs 190 kg net. The chamber must be placed on a level surface with adequate ventilation clearance. Reinforced packaging is used for transport; the unit must be kept upright during unloading and positioning.
The Top-Light Incubator 600 L provides 600 L of programmable illumination and temperature control for plant growth and microbial culture, with a stainless-steel chamber and glass door for easy observation, but requires careful ambient temperature management at low set points and a dedicated 220V/50Hz power supply.
Positive
- Programmable temperature and light control: LCD microcomputer controller enables repeatable photoperiod and temperature cycling experiments with 0.1°C resolution and 6-level illumination up to 10000 lux.
- Stainless-steel chamber with glass door: Mirror-finish stainless-steel interior and tempered-glass inner door facilitate visual inspection and cleaning, improving long-term lab hygiene and corrosion resistance.
Trade-offs
- Low-temperature ambient constraint: When set temperature is 10°C or below, ambient temperature must not exceed 26°C, limiting placement in warm labs without additional cooling.
- Heavy and power-specific: Unit weighs 190 kg and requires AC220V 50Hz, necessitating dedicated floor space and compatible electrical infrastructure.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.