Top-Light Incubator 250 L, 5–60 °C, 10000 Lux ATOMFAIR®

$2,100.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 250 L top-light incubator with 5–60 °C control, 0–10000 Lux illumination, 0.1 °C resolution and 800 W input. Order now.

SKU: AF-LE-E-GZXT-0250-250T
Category:
Brands:

Top-Light Incubator, 250 L
Research-grade laboratory product
Product Overview

Top-Light Incubator, 250 L is a practical chamber for plant growth, tissue culture, seed germination, cultivation, seedling raising, microbial culture and preservation, medicinal-material and building-material testing, insect rearing and quality inspection. It brings together 250 l of usable space, 5 to 60 C and 0 to 10000 lux (6 levels) illumination, so the chamber can keep samples in a steady, repeatable working condition.

The cabinet combines a visible glass inner door, cleanable stainless-steel surfaces and a top-light layout to make sample observation and chamber maintenance easier. The cabinet uses a mirror-finish stainless-steel inner chamber, a tempered-glass inner door, a cold-rolled steel exterior and top lighting, with an internal working room of 500 x 550 x 900 mm and an external footprint of 740 x 705 x 1560 mm. That combination of chamber size, shell build and liner material makes the unit easier to place, clean and use in routine laboratory work.

The family uses programmable temperature and light control to support plant-growth experiments and routine illuminated incubation. The stated input power is 800 W, and the timer range is 0 to 9999 min. It is well suited to the day-to-day work listed above, including culture, incubation, climate simulation or illuminated growth tasks, depending on the family.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-GZX250T
Capacity 250 L
Temperature Control Range 5 to 60 C
Temperature Resolution 0.1 C
Temperature Uniformity +/- 1 C
Light Intensity 0 to 10000 Lux (6 levels)
Lighting Faces 2 faces
Controller LCD microcomputer programmable controller
Chamber Material Mirror-finish stainless-steel inner chamber
Exterior Shell Cold-rolled steel shell with electrostatic powder coating
Power / Input 800 W
Power Supply AC220V 50Hz
Timer Range 0 to 9999 min
Internal Dimensions 500 x 550 x 900 mm
External Dimensions 740 x 705 x 1560 mm
Net Weight 110 Kg
Shelves / Trays 2 shelves
Configuration Note Top lighting and glass observation door support plant-growth experiments and daily visual inspection
Performance Features
  • Programmable control of temperature and light supports routine illuminated incubation workflows. This supports repeatable plant-growth and photoperiod experiments.
  • Top lighting helps create the illumination conditions needed for plant-growth experiments. This supports repeatable plant-growth and photoperiod experiments.
  • Mirror-finish stainless-steel chamber surfaces and a glass inner door support observation and cleaning. This helps with cleaning, corrosion resistance and long-term laboratory use.
  • Self-diagnosis, over-temperature self-limiting and power-off memory help protect the chamber during routine use. This helps preserve operation settings after power interruptions.
  • The series uses a clean cabinet structure with removable shelving for easier loading and maintenance. This supports more reliable day-to-day chamber use.
  • The same LCD operation framework keeps routine chamber control straightforward. This supports more reliable day-to-day chamber use.
APPLICATION SCOPE: Suitable for plant growth, tissue culture, seed germination, cultivation, seedling raising, microbial culture and preservation, medicinal-material and building-material testing, insect rearing and quality inspection in universities, laboratories, research institutes and quality-control environments that need controlled chamber performance.
HANDLING: Keep the chamber level, leave enough room for ventilation and confirm the selected shelf and lighting configuration before operation. Every unit is shipped with reinforced packaging for transport safety; keep the unit upright during unloading and positioning.
IMPORTANT NOTICE: When set temperature is 10 C or below, ambient temperature should not exceed 26 C. The page also states a general work environment of 5 to 40 C and relative humidity below 90%. Any quoted amount refers to the chamber body only and does not include freight. Freight should be confirmed separately according to the delivery destination.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator requires a level surface with adequate ventilation and ambient conditions within 5°C to 40°C and below 90% relative humidity. When the set temperature is 10°C or below, ambient temperature must not exceed 26°C to prevent performance degradation.

  • Level Surface Requirement: Place the incubator on a level surface to ensure stable operation and prevent mechanical stress.
  • Ventilation Clearance: Leave adequate space around the incubator for air circulation and heat dissipation.
  • Ambient Temperature Range: Operate the incubator within an ambient temperature range of 5°C to 40°C.
  • Humidity Limit: Maintain relative humidity below 90% to avoid condensation and electrical hazards.
  • Low Set Temperature Constraint: When the set temperature is 10°C or below, ensure ambient temperature does not exceed 26°C.

Position the incubator on a level surface with adequate ventilation and confirm the shelf and lighting configuration. Program the temperature and light cycles using the LCD controller, then load samples for incubation.

Required Equipment: LCD microcomputer programmable controller

  1. Position Incubator
    Position the incubator on a level surface with adequate ventilation for heat dissipation.
  2. Confirm Configuration
    Confirm the selected shelf configuration and lighting levels before operation.
  3. Program Settings
    Program the temperature and light cycles using the LCD controller to match the experimental protocol.

How does the 6-level light intensity control affect the temperature uniformity of the Top-Light Incubator, 250 L?

The incubator maintains a temperature uniformity of ±1°C across all six light intensity levels (0 to 10000 lux). However, when the set temperature is 10°C or below, the ambient temperature must not exceed 26°C to ensure accurate performance. This specification is derived from the product's technical data.

What are the electrical and space requirements for installing the Top-Light Incubator, 250 L in a standard laboratory?

The incubator requires an AC220V 50Hz power supply with 800W input power. The unit has external dimensions of 740 x 705 x 1560 mm and weighs 110 kg. It must be placed on a level surface with sufficient clearance for ventilation, and the ambient temperature should be between 5°C and 40°C with relative humidity below 90% for general operation.

What safety features does the Top-Light Incubator, 250 L include to protect samples during operation?

The incubator is equipped with self-diagnosis, over-temperature self-limiting, and power-off memory functions. These features help protect samples by automatically limiting temperature overshoot, detecting faults, and preserving operation settings after power interruptions, ensuring reliable long-term use.

The Top-Light Incubator, 250 L offers programmable temperature and light control with a mirror-finish stainless-steel chamber and glass inner door, suitable for plant growth and microbial culture. However, its top lighting from two faces and ambient temperature constraints at low set points require careful placement and application planning.

Positive

  • Programmable temperature and light control: The LCD microcomputer controller supports programmable temperature and light settings, enabling repeatable photoperiod experiments and routine illuminated incubation workflows.
  • Mirror-finish stainless-steel chamber and glass door: The mirror-finish stainless-steel inner chamber and tempered-glass inner door facilitate easy observation and cleaning, enhancing corrosion resistance and long-term laboratory use.

Trade-offs

  • Ambient temperature constraint at low set points: When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C, limiting placement options in warmer laboratory environments.
  • Limited top lighting configuration: The top lighting provides only 2 illuminated faces with 6 intensity levels up to 10000 lux, which may be insufficient for applications requiring uniform or higher light distribution across the chamber.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).