Four-Sided Programmable Climate Chamber, 180 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The chamber requires stable ambient conditions, with a maximum ambient temperature of 26°C when the set temperature is 10°C or below. Performance specifications are validated under no-load conditions at 20°C and 50%RH ambient humidity.
- Ambient Temperature Constraint: When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C to maintain performance.
- No-Load Performance Basis: Stated performance data are measured under no-load conditions at 20°C ambient temperature and 50%RH ambient humidity.
- Leveling and Positioning: The chamber must be kept level and upright during unloading and positioning to ensure proper operation.
This procedure covers the initial setup and programming of the chamber for controlled temperature, humidity, and light experiments. Follow these steps to ensure safe and accurate operation.
Required Equipment: LCD microcomputer programmable controller
- Position the chamber
Place the chamber on a level surface in a room with ambient temperature not exceeding 26°C when set temperature is 10°C or below. - Connect power supply
Connect the chamber to a grounded AC220V 50Hz power outlet with the required 900W capacity. - Set the program
Use the LCD controller to program the desired temperature, humidity, light intensity, and time cycles. - Load samples
Place samples on the shelves, ensuring adequate air circulation and avoiding overloading. - Start the cycle
Initiate the programmed cycle and monitor the chamber's operation for stability.
What ambient temperature must be maintained when operating the chamber at low set points such as 10°C or below?
When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C to ensure proper performance. This constraint is explicitly stated in the product specifications and is based on no-load testing at 20°C ambient and 50%RH. Exceeding this ambient limit may compromise temperature control accuracy and uniformity.
Does the four-sided illumination configuration support simultaneous photoperiod experiments and humidity-sensitive microbial cultures?
Yes, the chamber combines programmable control of temperature (5–60°C), humidity (50–90%RH with ±8%RH deviation), and four-sided illumination (0–18000 lux, 6 levels), allowing coordinated photoperiod and moisture regimes. The LCD microcomputer controller enables multi-step cycles, making it suitable for both plant growth and microbial culture applications in the same run. The mirror-finish stainless steel interior and glass inner door also facilitate observation and cleaning during mixed-use protocols.
What are the electrical and space requirements for installing the 180 L four-sided climate chamber?
The chamber requires a 900 W, AC220V 50Hz power supply and occupies an external footprint of 750 x 850 x 1525 mm with a net weight of 155.5 kg. The internal working space is 500 x 500 x 750 mm, and the unit must be kept level and upright during transport and installation. Additionally, for low-temperature operation (set point ≤10°C), the ambient temperature must not exceed 26°C, and stable ambient conditions are recommended for optimal performance.
The AF-QHX180L four-sided programmable climate chamber provides 180 L of usable space with coordinated temperature (5–60 °C), humidity (50–90% RH), and illumination (0–18000 lux, 6 levels) control, using a mirror-finish stainless-steel interior and a glass inner door for observation and cleaning. The four-sided lighting layout delivers more uniform photonic exposure for plant-growth and photoperiod experiments, while the programmable LCD controller supports multi-step cycles. Operational constraints include a ±8% RH humidity deviation, a maximum ambient temperature of 26 °C when set below 10 °C, and a 900 W input power requirement.
Positive
- Four-sided illumination for uniform exposure: The chamber provides illumination from four faces at up to 18000 lux across six levels, enabling more even and repeatable photoperiod and plant-growth experiments compared to single-sided lighting designs.
- Programmable multi-parameter control: The LCD microcomputer controller allows coordinated programming of temperature, humidity, light intensity, and timing (0–9999 min), supporting staged cultivation, conditioning, and climate-simulation workflows in a single unit.
Trade-offs
- Humidity deviation tolerance of ±8% RH: The specified humidity deviation of ±8% RH means that at a setpoint of 70% RH, actual chamber humidity may range from 62% to 78% RH, which may be insufficient for applications requiring tight moisture control.
- Ambient temperature limit at low setpoints: When the set temperature is 10 °C or below, the ambient temperature must not exceed 26 °C; exceeding this limit may compromise low-temperature stability or cause the chamber to fail to maintain setpoint.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).