Programmable Climate Chamber, 70 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The chamber requires stable ambient conditions and specific temperature-humidity limits to operate safely and maintain performance. When set temperature is 10°C or below, ambient temperature must not exceed 26°C; when setpoint exceeds 40°C, humidity should generally not exceed 80%RH.
- Ambient Temperature Limit: When the chamber set temperature is 10°C or below, the ambient room temperature must not exceed 26°C to prevent compressor overload.
- Humidity Setpoint Limit: When the chamber temperature setpoint exceeds 40°C, the humidity setpoint should generally not exceed 80%RH to avoid condensation or sensor drift.
- Heat Source Proximity: Position the chamber away from direct heat sources and maintain stable room temperature to ensure accurate environmental control.
- Transport Orientation: Keep the unit upright during unloading and positioning to prevent refrigerant migration or compressor damage.
- Performance Reference Conditions: All performance specifications are based on no-load testing at 20°C ambient temperature and 50%RH ambient humidity.
Install the chamber in a stable environment with adequate ventilation and power supply. Program the LCD controller for desired temperature, humidity, and light cycles while observing operational limits.
Required Equipment: AC220V 50Hz power supply, LCD microcomputer programmable controller, Stable laboratory bench or surface
- Position chamber
Position the chamber on a stable surface away from direct heat sources. - Verify ambient conditions
Ensure ambient room temperature does not exceed 26°C when operating at set temperatures of 10°C or below. - Confirm accessories
Confirm that all selected accessory packages are installed before powering on. - Connect power
Connect the chamber to an AC220V 50Hz power supply. - Set parameters
Set temperature, humidity, and light intensity parameters using the LCD controller. - Program cycles
Program time cycles using the timer range from 0 to 9999 minutes for automated operation. - Monitor operation
Monitor chamber operation through the glass inner door and respond to self-diagnosis alerts.
What ambient temperature conditions are required when operating the Atomfair AF-QHX70T climate chamber at low set temperatures (10°C or below)?
When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C to maintain stable chamber performance. This constraint is explicitly stated in the product specifications and is critical for achieving reliable low-temperature operation without exceeding the cooling system's capacity.
Can the Atomfair AF-QHX70T climate chamber be integrated with CO2 control for advanced plant growth experiments?
Yes, the chamber supports CO2 control through optional accessories: a CO2 inlet and a CO2 controller. These are listed as optional add-ons, allowing researchers to customize the chamber for experiments requiring precise atmospheric composition beyond standard temperature, humidity, and light control.
What are the electrical power specifications and handling considerations for the Atomfair AF-QHX70T 70L programmable climate chamber?
The chamber requires an AC220V 50Hz power supply with a total input power of 500 W. For safe installation, keep the unit away from direct heat sources, maintain stable room temperature, and keep it upright during unloading and positioning. The chamber weighs 61 kg net and should be placed on a stable surface with adequate clearance for ventilation.
The Atomfair AF-QHX70T 70 L programmable climate chamber integrates temperature, humidity, and illumination control for plant growth and biological applications, but imposes operational limits on low-temperature and high-humidity setpoints alongside AC220V power requirements.
Positive
- Programmable multi-parameter environmental control: The chamber provides programmable control of temperature, humidity, light intensity, and time, enabling simulation of natural climate conditions for plant growth, tissue culture, and microbial studies.
- Top lighting for photoperiod experiments: The top lighting structure with 2 faces and 6 intensity levels (0-10000 lux) is specifically suited for germination and plant-growth experiments requiring repeatable photoperiod control.
Trade-offs
- Temperature-humidity coupling constraints: At set temperatures below 10°C, ambient temperature must not exceed 26°C; at set temperatures above 40°C, humidity setpoint should generally not exceed 80% RH, limiting certain combined conditions.
- Power supply and installation prerequisites: The chamber requires AC220V 50Hz mains supply and stable room temperature conditions; performance is based on no-load testing at 20°C/50%RH, so actual performance may vary with load and ambient conditions.