Programmable LCD Artificial Climate Chamber, 800 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The chamber requires a working environment of +5 to 30 °C and a dedicated AC 220 V, 50 Hz power supply rated at 2800 W. Continuous operation schedules should not exceed 180 hours under proper installation conditions to maintain compressor and sensor reliability.
- Temperature and Humidity Control Limits: Temperature control range is 4 to 50 °C in no-light mode and 10 to 50 °C in illuminated mode, with humidity control from 50% to 90% RH and a deviation of ±5% to 7% RH.
- Lighting and Illumination Constraints: Illumination is adjustable from 0 to 30000 lx in six steps, with partition lighting at two levels, and the lighting form varies by chamber size.
- Installation Space and Access Requirements: Installation planning must accommodate external dimensions of 1475 x 890 x 1780 mm and keep air inlets, test ports, shelving, drain areas, doors, and controller surfaces accessible for cleaning and maintenance.
- Over-Temperature Alarm Protection: Independent over-temperature alarm protection helps safeguard samples during unattended operation by notifying operators when abnormal conditions occur.
Confirm installation space against the external dimensions and prepare the specified power supply before unpacking. Keep the packed chamber upright and use suitable lifting equipment during unloading and positioning.
Required Equipment: Suitable lifting equipment (e.g., pallet jack or forklift), AC 220 V, 50 Hz power supply with 2800 W capacity
- Unpack and Position the Chamber
Unpack the chamber using suitable lifting equipment, keeping it upright, and position it in a location with ambient temperature between +5 and 30 °C and adequate clearance for air circulation and maintenance access. - Connect Power Supply
Connect the chamber to a dedicated AC 220 V, 50 Hz power supply rated at 2800 W, ensuring the circuit is properly grounded and protected. - Set Temperature, Humidity, and Light Parameters
Use the LCD microcomputer controller to program the desired temperature (4–50 °C no-light or 10–50 °C illuminated), humidity (50–90% RH), and light intensity (0–30000 lx in six steps) via the menu-based interface. - Verify Environmental Stability
Allow the chamber to stabilize for at least 30 minutes, then verify that temperature fluctuation is within ±1 °C and humidity deviation is within ±5% to 7% RH before loading samples. - Load Samples and Initiate Program
Load samples onto the removable stainless-steel shelves, close the door securely, and start the programmed cycle for staged temperature, humidity, and light control. - Monitor Operation and Respond to Alarms
Monitor the multi-parameter display for any over-temperature alarms or abnormal conditions, and take corrective action immediately if an alarm activates.
What is the difference between the no-light and illuminated temperature ranges on the MGC-850HP artificial climate chamber?
The illuminated-mode temperature range is 10 to 50 C, whereas no-light mode extends down to 4 to 50 C; temperature fluctuation/uniformity is stated as +/-1 C. Illumination is adjustable from 0 to 30000 lx in six steps with partition lighting on two levels, and the exact lighting form depends on chamber size.
Can the MGC-850HP chamber be configured for CO2 enrichment and external data acquisition?
Yes, optional accessories include a CO2 inlet, infrared CO2 controller, RS232/485 communication interface and software, USB data storage, embedded printer, wireless alarm system, and light-intensity detection/control system. These options allow the chamber to be adapted for atmosphere support, alarm notification, data output, and programmable operation. Because the accessory package affects controller type, lighting form, and humidity function, Atomfair advises confirming the exact configuration before ordering.
What installation space, power supply, and handling conditions are required for the 800 L artificial climate chamber?
Plan for external dimensions of 1475 x 890 x 1780 mm and a 2800 W power requirement on AC 220 V, 50 Hz; the specified working environment is +5 to 30 C. Keep air inlets, test ports, shelving, drain areas, doors, and controller surfaces accessible for cleaning and maintenance. Shipments must remain upright with suitable lifting equipment during unloading, and continuous operation is recommended for at least 180 hours under proper installation conditions.
The 800 L LCD artificial climate chamber integrates coordinated temperature, humidity, and lighting control with a 304 stainless-steel interior, supporting plant cultivation and environmental simulation. However, its ±1°C temperature uniformity and ±5–7% RH humidity deviation impose operational constraints for high-precision protocols.
Positive
- Integrated Humidity and Light Control: Provides coordinated temperature, humidity, and light cycling for cultivation and simulation workflows requiring simultaneous environmental control.
- 304 Stainless-Steel Chamber Interior: Removable shelving and corrosion-resistant interior facilitate repeated cleaning and maintain hygiene for long-duration laboratory use.
Trade-offs
- Temperature Uniformity Tolerance: Temperature fluctuation and uniformity within ±1°C may limit use in experiments requiring tighter thermal stability.
- Humidity Deviation Range: Humidity control deviation of ±5% to ±7% RH requires careful experimental design for humidity-sensitive applications.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).