LCD Artificial Climate Chamber 800 L 304 Stainless ATOMFAIR®

$19,000.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

800 L LCD artificial climate chamber with 4–50 °C no-light control, 10–50 °C illuminated operation, 50–90%RH humidity, 0–30000 lx lighting control.

SKU: AF-LE-E-MGAC-0800-H800
Category:
Brands:

LCD Artificial Climate Chamber, 800 L
Research-grade laboratory product
Product Overview

LCD Artificial Climate Chamber, 800 L is a LCD artificial climate chamber built for plant cultivation, seedling research, insect rearing, biological culture and environmental simulation that require coordinated temperature, humidity and light control. This configuration provides 800 l chamber volume, No-light mode: 4 to 50 C; illuminated mode: 10 to 50 C, 50%rh to 90%rh humidity control, 0 to 30000 lx, six-step adjustable illumination, 304 stainless-steel chamber interior with removable shelving and lcd microcomputer controller with menu-based operation and large-screen multi-parameter display for stable day-to-day laboratory operation.

These LCD artificial-climate models combine imported compressor and humidity-sensor components with stainless-steel inner chamber construction, adjustable shelving and test-port access. The chamber combines imported compressor and circulation-fan assembly with imported humidity sensor and microcomputer temperature-humidity control system, 4 shelves and an interior size of 965 x 580 x 1430 mm, supporting incubation, cultivation, climate simulation or conditioned test work where repeatable environmental control is important.

These models are suitable when a laboratory needs humidity control in addition to illumination and temperature regulation, while still preferring the standard LCD-style operation interface and optional communication or alarm accessories. Installation planning can be based on the external size of 1475 x 890 x 1780 mm and the stated power requirement of 2700 W. Optional functions such as rs232/485 communication interface and software; embedded printer; usb data storage; wireless alarm system; co2 inlet; infrared co2 controller; light-intensity detection and control system allow the unit to be adapted for alarm notification, data output, programmable operation, atmosphere support or other application-specific requirements.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-MAH0800
Manufacturer Model MGC-800H
Capacity 800 L
Temperature Control Range No-light mode: 4 to 50 C; illuminated mode: 10 to 50 C
Temperature Resolution 0.1 C
Temperature Fluctuation / Uniformity +/- 1 C
Humidity Function 50%RH to 90%RH
Humidity Deviation +/- 5%RH to 7%RH
Lighting Configuration 0 to 30000 LX, six-step adjustable; partition lighting, two levels; Lighting form varies by model and includes three-side or partition lighting according to chamber size
Controller LCD microcomputer controller with menu-based operation and large-screen multi-parameter display
Chamber Material 304 stainless-steel chamber interior with removable shelving
Power / Input 2700 W
Power Supply AC 220 V, 50 Hz
Working Environment +5 to 30 C
Sensor Configuration imported humidity sensor and microcomputer temperature-humidity control system
Cooling System imported compressor and circulation-fan assembly
Continuous Operation Guidance Recommended for continuous operation schedules of not less than 180 hours under proper installation conditions
Internal Dimensions 965 x 580 x 1430 mm
External Dimensions 1475 x 890 x 1780 mm
Shelves / Light Decks 4 shelves
Program Function Standard LCD artificial-climate control for routine temperature, humidity and light programs
Optional Accessories and Functions RS232/485 communication interface and software; embedded printer; USB data storage; wireless alarm system; CO2 inlet; infrared CO2 controller; light-intensity detection and control system
Performance Features
  • LCD menu control allows temperature, humidity and light values to be reviewed together, which helps routine artificial-climate operation. This improves parameter review, setpoint editing and day-to-day operation in controlled chamber workflows.
  • Imported humidity sensing supports more reliable environmental tracking for cultivation and simulation workflows. This supports humidity-sensitive incubation, cultivation, conditioning and stability-study applications.
  • Stainless-steel chamber construction with removable shelves improves hygiene, cleaning access and sample-space adjustment. This helps support repeated cleaning, chamber hygiene and long-duration laboratory use.
  • Integrated light and humidity control makes the chamber useful for cultivation programs that need coordinated environmental cycling. This supports humidity-sensitive incubation, cultivation, conditioning and stability-study applications.
  • Independent over-temperature alarm protection helps safeguard samples when unattended running is required. This reduces operational risk by helping protect samples and notifying operators when abnormal conditions occur.
  • Optional CO2, communication, printing, alarm and light-detection accessories help extend the chamber to more advanced climate-control tasks. This reduces operational risk by helping protect samples and notifying operators when abnormal conditions occur.
APPLICATION SCOPE: Suitable for plant cultivation, seedling research, insect rearing, biological culture and environmental simulation that require coordinated temperature, humidity and light control in universities, research institutes, pharmaceutical quality-control laboratories, agricultural research programs and industrial test environments that require controlled chamber operation.
HANDLING: Confirm installation space against 1475 x 890 x 1780 mm, prepare the specified power supply, and keep air inlets, test ports, shelving, drain areas, doors and controller surfaces accessible for cleaning and maintenance. Every unit is shipped with reinforced packaging to reduce movement and impact during transport; keep the packed chamber upright and use suitable lifting equipment during unloading and positioning.
IMPORTANT NOTICE: Confirm the exact controller type, lighting form, humidity function, communication option and accessory package before ordering. Any displayed amount refers to the chamber body only and does not include freight. Freight is quoted separately and should be confirmed according to the delivery location and shipping method.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

Operate the chamber within the specified ambient temperature range of 5 to 30°C to ensure reliable compressor performance. Maintain unobstructed access to air inlets, test ports, and drain areas to prevent overheating and allow routine maintenance.

  • Installation Space and Power: Confirm installation space of at least 1475 x 890 x 1780 mm and prepare a dedicated AC 220V, 50 Hz power supply before positioning the chamber.
  • Handling and Positioning: Keep the packed chamber upright during transport and use suitable lifting equipment to avoid impact damage during unloading and positioning.
  • Continuous Operation: For continuous operation, schedule runs of at least 180 hours to maintain stable conditions, but avoid exceeding the recommended duration without inspection.
  • Over-Temperature Alarm: Enable the independent over-temperature alarm protection when operating unattended to safeguard samples and trigger notification if abnormal conditions occur.
  • Optional Accessories: When adding optional CO2, communication, or light-detection systems, verify compatibility with the standard controller and ensure proper installation per the accessory manual.

Follow these steps to safely install, power on, and configure the chamber for a controlled environment experiment. Ensure all tools and safety precautions are in place before starting.

Required Equipment: Lifting equipment (forklift or pallet jack)

  1. Prepare Installation Site
    Confirm the installation space against the external dimensions of 1475 x 890 x 1780 mm and prepare a dedicated AC 220V, 50 Hz power supply.
  2. Unpack Chamber
    Unpack the chamber using suitable lifting equipment, keeping the unit upright at all times to avoid refrigerant or compressor damage.
  3. Position and Ventilate
    Place the chamber on a level surface, ensuring at least 10 cm clearance around air inlets and test ports for proper ventilation.
  4. Connect Power
    Connect the chamber to the specified power supply and switch on the main power, then verify the LCD controller activates and displays room temperature.
  5. Configure Parameters
    Set the desired temperature, humidity, and light intensity parameters using the menu-based LCD controller, and enable the over-temperature alarm for unattended operation.
  6. Stabilize Chamber
    Allow the chamber to stabilize for at least 30 minutes after reaching setpoints before introducing samples to ensure uniform conditions.
  7. Monitor and Record
    Periodically check the displayed parameters and alarm status, and record data using optional RS232/USB interfaces if available.

What is the humidity control range and accuracy of the 800 L LCD Artificial Climate Chamber?

The chamber controls humidity from 50%RH to 90%RH with a deviation of ±5%RH to 7%RH. This capability is supported by an imported humidity sensor and microcomputer temperature-humidity control system, making it suitable for humidity-sensitive incubation and cultivation workflows.

Which optional accessories can be integrated with the 800 L LCD Artificial Climate Chamber for advanced data logging and environmental control?

Optional accessories include an RS232/485 communication interface and software, embedded printer, USB data storage, wireless alarm system, CO2 inlet, infrared CO2 controller, and light-intensity detection and control system. These allow the chamber to be adapted for alarm notification, data output, programmable operation, and atmosphere support.

What are the installation and continuous operation requirements for the 800 L LCD Artificial Climate Chamber?

The chamber requires an AC 220V, 50 Hz power supply with a 2700 W input, and should be installed in a working environment of +5 to 30°C. The external dimensions are 1475 x 890 x 1780 mm, and it is recommended for continuous operation schedules of not less than 180 hours under proper installation conditions.

The LCD Artificial Climate Chamber, 800 L integrates temperature, humidity, and six-step adjustable light control in a 304 stainless steel interior, suited for plant cultivation and environmental simulation. Its humidity range of 50–90%RH and temperature uniformity of ±1°C impose constraints for low-humidity or high-precision applications.

Positive

  • Coordinated environmental cycling control: Integrated temperature, humidity, and light control supports cultivation programs requiring repeatable day-night or multi-parameter simulation, with six-step adjustable illumination and imported humidity sensing for reliable tracking.
  • Stainless steel interior with removable shelving: 304 stainless steel chamber lining and adjustable shelves improve hygiene, cleaning access, and sample-space flexibility, supporting long-duration laboratory use and repeated decontamination.

Trade-offs

  • Humidity range limited to 50–90%RH: The chamber cannot control humidity below 50%RH, which may preclude applications such as desiccation studies or low-humidity storage without external dehumidification equipment.
  • Temperature uniformity ±1°C: A fluctuation and uniformity specification of ±1°C may be insufficient for highly temperature-sensitive assays, material stability tests, or seed germination studies requiring tighter thermal gradients.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).