Programmable LCD Light Incubator 300 L AF-MBP0300 ATOMFAIR®

$8,200.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Programmable 300 L LCD light incubator, 4–50 °C no-light, 10–50 °C illuminated, 0–20,000 lx six-step lighting, 304 stainless interior. Order now.

SKU: AF-LE-E-MGLI-0300-BP35
Category:
Brands:

Programmable LCD Light Incubator, 300 L
Research-grade laboratory product
Product Overview

Programmable LCD Light Incubator, 300 L is a LCD light incubator built for microbial culture, plant cultivation, seed testing, insect rearing and other light-controlled incubation workflows. This configuration provides 300 l chamber volume, No-light mode: 4 to 50 C; illuminated mode: 10 to 50 C, 0 to 20000 lx, six-step adjustable illumination, 304 stainless-steel chamber interior with removable shelving and lcd microcomputer controller with menu-based operation and large-screen data display for stable day-to-day laboratory operation.

This family uses fluorine-free design, imported compressor and fan components, stainless-steel interior construction, rounded internal corners, adjustable shelf spacing and a left-side test port for measurement access. The chamber combines imported compressor and circulation-fan assembly with microcomputer temperature-control system, 3 shelves and an interior size of 520 x 550 x 1140 mm, supporting incubation, cultivation, climate simulation or conditioned test work where repeatable environmental control is important.

These LCD models are positioned for laboratories that need stable illuminated incubation with selectable single-side, double-side, three-side or partition lighting, plus optional communication, alarm and atmosphere-related accessories. Installation planning can be based on the external size of 830 x 850 x 1850 mm and the stated power requirement of 1700 W. Optional functions such as rs232/485 communication interface and software; embedded printer; usb data storage; wireless alarm system; co2 inlet; infrared co2 controller; light-intensity detection and control system allow the unit to be adapted for alarm notification, data output, programmable operation, atmosphere support or other application-specific requirements.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-MBP0300
Manufacturer Model MGC-350BP
Capacity 300 L
Temperature Control Range No-light mode: 4 to 50 C; illuminated mode: 10 to 50 C
Temperature Resolution 0.1 C
Temperature Fluctuation / Uniformity +/- 1 C
Humidity Function No active humidity control stated for this configuration
Lighting Configuration 0 to 20000 LX, six-step adjustable; three-side lighting; Lighting form varies by model and includes single-side, double-side, three-side or partition lighting
Controller LCD microcomputer controller with menu-based operation and large-screen data display
Chamber Material 304 stainless-steel chamber interior with removable shelving
Power / Input 1700 W
Power Supply AC 220 V, 50 Hz
Working Environment +5 to 30 C
Sensor Configuration microcomputer temperature-control system
Cooling System imported compressor and circulation-fan assembly
Continuous Operation Guidance Recommended for continuous operation schedules of not less than 180 hours under proper installation conditions
Internal Dimensions 520 x 550 x 1140 mm
External Dimensions 830 x 850 x 1850 mm
Shelves / Light Decks 3 shelves
Program Function Programmable control version for staged lighting and temperature operation
Optional Accessories and Functions RS232/485 communication interface and software; embedded printer; USB data storage; wireless alarm system; CO2 inlet; infrared CO2 controller; light-intensity detection and control system
Performance Features
  • LCD menu control and large-screen display keep temperature and lighting values visible during routine laboratory operation. This improves parameter review, setpoint editing and day-to-day operation in controlled chamber workflows.
  • Fluorine-free cooling design with imported compressor and fan components supports efficient chamber running and long service life. This helps maintain dependable low-temperature performance and stable chamber recovery during repeated use.
  • 304 stainless-steel interior construction with rounded corners and removable shelving helps improve cleaning efficiency and sample layout flexibility. This helps support repeated cleaning, chamber hygiene and long-duration laboratory use.
  • Model-specific lighting structures allow the user to match illumination intensity and distribution to cultivation depth and chamber size. This is valuable for plant-growth and photoperiod experiments that depend on repeatable lighting conditions.
  • Independent over-temperature alarm protection helps stop the unit and alert users when abnormal temperature conditions occur. This reduces operational risk by helping protect samples and notifying operators when abnormal conditions occur.
  • Optional communication, printing, USB storage, CO2 and light-detection functions extend the chamber for documented and application-specific workflows. This is valuable for plant-growth and photoperiod experiments that depend on repeatable lighting conditions.
APPLICATION SCOPE: Suitable for microbial culture, plant cultivation, seed testing, insect rearing and other light-controlled incubation workflows in universities, research institutes, pharmaceutical quality-control laboratories, agricultural research programs and industrial test environments that require controlled chamber operation.
HANDLING: Confirm installation space against 830 x 850 x 1850 mm, prepare the specified power supply, and keep air inlets, test ports, shelving, drain areas, doors and controller surfaces accessible for cleaning and maintenance. Every unit is shipped with reinforced packaging to reduce movement and impact during transport; keep the packed chamber upright and use suitable lifting equipment during unloading and positioning.
IMPORTANT NOTICE: Confirm the exact controller type, lighting form, humidity function, communication option and accessory package before ordering. Any displayed amount refers to the chamber body only and does not include freight. Freight is quoted separately and should be confirmed according to the delivery location and shipping method.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This incubator imposes operating constraints including ambient temperature range of 5–30°C and dedicated AC 220 V, 50 Hz power supply. Continuous operation beyond 180 hours requires proper installation, and the over-temperature alarm automatically stops the unit if abnormal conditions occur.

  • Ambient Temperature Limit: The chamber must be operated in an ambient environment between 5°C and 30°C.
  • Power Supply Requirement: The unit requires a dedicated AC 220 V, 50 Hz power supply.
  • Continuous Operation Threshold: Continuous operation schedules should not exceed 180 hours without proper installation conditions.
  • Over-Temperature Protection: An independent over-temperature alarm stops the unit and alerts users when abnormal temperature conditions occur.
  • Installation Space: The external dimensions of 830 x 850 x 1850 mm must be accommodated in the installation area.

This incubator requires careful unpacking and installation to ensure stable operation. Follow these steps to prepare the unit for first use.

Required Equipment: Suitable lifting equipment

  1. Confirm Installation Space
    Confirm the installation space accommodates the external dimensions of 830 x 850 x 1850 mm.
  2. Prepare Power Supply
    Prepare the specified power supply of AC 220 V, 50 Hz.
  3. Unpack and Position Chamber
    Unpack the chamber, keep it upright, and position it using suitable lifting equipment.

What is the temperature fluctuation and uniformity for the Programmable LCD Light Incubator 300 L under illuminated conditions?

The incubator specifies a temperature fluctuation and uniformity of ±1°C across the chamber. In illuminated mode the control range is 10 to 50°C, and in no-light mode it extends from 4 to 50°C. This performance is supported by an imported compressor and microcomputer temperature-control system with 0.1°C resolution.

Can the Atomfair MGC-350BP light incubator be equipped with CO2 control or data communication for plant growth experiments?

Yes, the unit supports optional accessories including a CO₂ inlet and infrared CO₂ controller for atmosphere management, as well as RS232/485 communication interface and software, embedded printer, USB data storage, and wireless alarm system. These options enable documented, programmable operation for growth and photoperiod studies.

What are the installation space and power supply requirements for the 300 L light incubator?

The external dimensions are 830 × 850 × 1850 mm, requiring adequate clearance for air inlets and service access. The unit requires a 1700 W power supply at AC 220 V, 50 Hz. Continuous operation of at least 180 hours is recommended under proper installation conditions, with a working environment of +5 to 30°C.

The AF-LE-E-MGLI-0300-BP35 (MGC-350BP) is a 300 L programmable LCD light incubator with a 304 stainless-steel interior, three-side lighting up to 20000 lx, and temperature control from 4 to 50 °C (no-light) or 10 to 50 °C (illuminated), designed for light-controlled incubation workflows requiring repeatable environmental conditions.

Positive

  • 304 stainless-steel interior with rounded corners: The chamber interior is constructed from 304 stainless steel with rounded internal corners and removable shelving, facilitating cleaning, hygiene maintenance, and flexible sample layout during long-duration use.
  • Six-step adjustable three-side lighting: Illumination is adjustable from 0 to 20000 lx in six steps with three-side lighting, allowing users to match light intensity and distribution to cultivation depth and photoperiod experiment requirements.

Trade-offs

  • No active humidity control: This configuration does not include active humidity control, limiting its use in applications where precise relative humidity regulation is required.
  • High power requirement of 1700 W: The unit requires a 1700 W power supply at AC 220 V, 50 Hz, which may necessitate dedicated electrical infrastructure and careful installation planning in existing laboratory facilities.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).