LCD Light Incubator 300 L AF-MLB0300 ATOMFAIR®

$7,400.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 300 L LCD light incubator with 4-50 °C no-light control, 10-50 °C illuminated operation, 0-20000 lx lighting and 0.1 °C resolution.

SKU: AF-LE-E-MGLI-0300-B300
Category:
Brands:

LCD Light Incubator, 300 L
Research-grade laboratory product
Product Overview

LCD Light Incubator, 300 L is a LCD light incubator built for microbial culture, plant cultivation, seed testing, insect rearing and other light-controlled incubation workflows. This configuration provides 300 l chamber volume, No-light mode: 4 to 50 C; illuminated mode: 10 to 50 C, 0 to 20000 lx, six-step adjustable illumination, 304 stainless-steel chamber interior with removable shelving and lcd microcomputer controller with menu-based operation and large-screen data display for stable day-to-day laboratory operation.

This family uses fluorine-free design, imported compressor and fan components, stainless-steel interior construction, rounded internal corners, adjustable shelf spacing and a left-side test port for measurement access. The chamber combines imported compressor and circulation-fan assembly with microcomputer temperature-control system, 3 shelves and an interior size of 520 x 550 x 1140 mm, supporting incubation, cultivation, climate simulation or conditioned test work where repeatable environmental control is important.

These LCD models are positioned for laboratories that need stable illuminated incubation with selectable single-side, double-side, three-side or partition lighting, plus optional communication, alarm and atmosphere-related accessories. Installation planning can be based on the external size of 830 x 850 x 1850 mm and the stated power requirement of 1450 W. Optional functions such as rs232/485 communication interface and software; embedded printer; usb data storage; wireless alarm system; co2 inlet; infrared co2 controller; light-intensity detection and control system allow the unit to be adapted for alarm notification, data output, programmable operation, atmosphere support or other application-specific requirements.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-MLB0300
Manufacturer Model MGC-300B
Capacity 300 L
Temperature Control Range No-light mode: 4 to 50 C; illuminated mode: 10 to 50 C
Temperature Resolution 0.1 C
Temperature Fluctuation / Uniformity +/- 1 C
Humidity Function No active humidity control stated for this configuration
Lighting Configuration 0 to 20000 LX, six-step adjustable; three-side lighting; Lighting form varies by model and includes single-side, double-side, three-side or partition lighting
Controller LCD microcomputer controller with menu-based operation and large-screen data display
Chamber Material 304 stainless-steel chamber interior with removable shelving
Power / Input 1450 W
Power Supply AC 220 V, 50 Hz
Working Environment +5 to 30 C
Sensor Configuration microcomputer temperature-control system
Cooling System imported compressor and circulation-fan assembly
Continuous Operation Guidance Recommended for continuous operation schedules of not less than 180 hours under proper installation conditions
Internal Dimensions 520 x 550 x 1140 mm
External Dimensions 830 x 850 x 1850 mm
Shelves / Light Decks 3 shelves
Program Function Standard LCD control for routine lighting and temperature operation
Optional Accessories and Functions RS232/485 communication interface and software; embedded printer; USB data storage; wireless alarm system; CO2 inlet; infrared CO2 controller; light-intensity detection and control system
Performance Features
  • LCD menu control and large-screen display keep temperature and lighting values visible during routine laboratory operation. This improves parameter review, setpoint editing and day-to-day operation in controlled chamber workflows.
  • Fluorine-free cooling design with imported compressor and fan components supports efficient chamber running and long service life. This helps maintain dependable low-temperature performance and stable chamber recovery during repeated use.
  • 304 stainless-steel interior construction with rounded corners and removable shelving helps improve cleaning efficiency and sample layout flexibility. This helps support repeated cleaning, chamber hygiene and long-duration laboratory use.
  • Model-specific lighting structures allow the user to match illumination intensity and distribution to cultivation depth and chamber size. This is valuable for plant-growth and photoperiod experiments that depend on repeatable lighting conditions.
  • Independent over-temperature alarm protection helps stop the unit and alert users when abnormal temperature conditions occur. This reduces operational risk by helping protect samples and notifying operators when abnormal conditions occur.
  • Optional communication, printing, USB storage, CO2 and light-detection functions extend the chamber for documented and application-specific workflows. This is valuable for plant-growth and photoperiod experiments that depend on repeatable lighting conditions.
APPLICATION SCOPE: Suitable for microbial culture, plant cultivation, seed testing, insect rearing and other light-controlled incubation workflows in universities, research institutes, pharmaceutical quality-control laboratories, agricultural research programs and industrial test environments that require controlled chamber operation.
HANDLING: Confirm installation space against 830 x 850 x 1850 mm, prepare the specified power supply, and keep air inlets, test ports, shelving, drain areas, doors and controller surfaces accessible for cleaning and maintenance. Every unit is shipped with reinforced packaging to reduce movement and impact during transport; keep the packed chamber upright and use suitable lifting equipment during unloading and positioning.
IMPORTANT NOTICE: Confirm the exact controller type, lighting form, humidity function, communication option and accessory package before ordering. Any displayed amount refers to the chamber body only and does not include freight. Freight is quoted separately and should be confirmed according to the delivery location and shipping method.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator must be operated within a +5 to 30°C working environment and requires a 1450W, 220V AC power supply. Continuous operation beyond 180 hours demands proper installation conditions to maintain temperature and lighting stability.

  • Temperature Mode Constraint: Temperature control range differs between no-light mode (4 to 50°C) and illuminated mode (10 to 50°C), requiring mode-dependent setpoint selection.
  • Lighting Configuration Constraint: The chamber provides three-side lighting with six-step adjustable illumination from 0 to 20000 lx, and the lighting form is model-specific.
  • Installation Space Constraint: Installation requires an external footprint of 830 x 850 x 1850 mm and accessible air inlets, test ports, shelving, drain areas, doors, and controller surfaces.
  • Optional Accessory Integration Constraint: Optional RS232/485 communication, printer, USB storage, wireless alarm, CO2 inlet, infrared CO2 controller, and light-intensity detection systems require additional configuration and calibration.

Proper installation requires confirmed space and power, careful unpacking and positioning, and ensuring accessibility for maintenance. The chamber must be kept upright during transport and positioned with suitable lifting equipment.

Required Equipment: Suitable lifting equipment (e.g., forklift or pallet jack)

  1. Confirm Installation Space and Power
    Confirm the installation space against the external dimensions of 830 x 850 x 1850 mm and prepare the specified AC 220 V, 50 Hz power supply.
  2. Keep Chamber Upright During Transport
    Keep the packed chamber upright during transport and unloading to prevent damage to the compressor and internal components.
  3. Position Chamber with Lifting Equipment
    Use suitable lifting equipment to position the chamber in the designated location, ensuring stable and level placement.
  4. Ensure Accessibility for Maintenance
    Ensure that air inlets, test ports, shelving, drain areas, doors, and controller surfaces remain accessible for cleaning and maintenance.

What is the temperature uniformity and fluctuation under illuminated conditions for the MGC-300B light incubator?

The temperature fluctuation and uniformity is ±1°C for both no-light and illuminated modes. The illuminated mode operates from 10 to 50°C, and the unit uses an imported compressor and circulation-fan assembly to maintain stability. No separate uniformity specification is provided for the illuminated state beyond the stated ±1°C.

Can the LCD Light Incubator MGC-300B be integrated with external data logging or CO2 control systems?

Yes, optional accessories include an RS232/485 communication interface and software, embedded printer, USB data storage, CO2 inlet, and infrared CO2 controller. These allow integration with external monitoring, data logging, and atmosphere control for specific applications such as plant growth or microbial culture requiring documented conditions.

What are the continuous operation recommendations and over-temperature protection features for the 300L incubator?

The unit is recommended for continuous operation schedules of not less than 180 hours under proper installation conditions. It features independent over-temperature alarm protection that stops the unit and alerts users when abnormal temperature conditions occur, reducing operational risk to samples and providing early notification of chamber anomalies.

The AF-MLB0300 (MGC-300B) 300 L LCD light incubator provides a 304 stainless-steel chamber with fluorine-free compressor cooling, six-step adjustable illumination up to 20000 lx, and a temperature range of 4–50 °C (no-light) or 10–50 °C (illuminated), suitable for microbial culture, plant growth, and seed testing. Its design includes imported compressor and fan components, rounded interior corners, and optional RS232/485 communication, CO2 inlet, and light-intensity detection, but lacks active humidity control and requires a minimum 180-hour continuous operation schedule for stable performance.

Positive

  • Fluorine-free compressor cooling: The imported compressor and circulation-fan assembly provide efficient, low-temperature operation with reduced environmental impact, supporting stable chamber recovery and long service life during repeated use.
  • 304 stainless-steel interior with rounded corners: The chamber interior is constructed from 304 stainless steel with rounded corners and removable shelving, improving cleaning efficiency, hygiene, and sample layout flexibility for long-duration laboratory workflows.

Trade-offs

  • No active humidity control: The unit does not include active humidity regulation, limiting its use in applications requiring precise moisture control, such as certain plant tissue culture or microbial assays.
  • Minimum 180-hour continuous operation recommended: For stable performance, the chamber is recommended for continuous operation schedules of not less than 180 hours under proper installation conditions, which may constrain intermittent use patterns.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).