LCD Light Incubator, 300 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The chamber must be installed in an environment with ambient temperature between 5 and 30 °C and powered by AC 220 V, 50 Hz. Continuous operation is recommended for at least 180 hours under proper installation, and the unit must be transported and positioned upright using suitable lifting equipment.
- Ambient Temperature Constraint: Operate the chamber only in an ambient temperature range of 5 to 30 °C to ensure proper temperature control and compressor function.
- Power Supply Requirement: Connect the chamber to a dedicated AC 220 V, 50 Hz power supply with the specified 1200 W capacity to avoid electrical overload.
- Continuous Operation Guidance: Plan for continuous operation schedules of no less than 180 hours under proper installation conditions to stabilize the chamber environment.
- Upright Transport Requirement: Keep the packed chamber upright at all times during transport and use suitable lifting equipment to prevent damage to the compressor and refrigeration system.
- Over-Temperature Alarm Protection: The independent over-temperature alarm will stop the unit and alert users when abnormal temperature conditions occur, requiring immediate operator attention.
Confirm the installation space and power supply, then unpack the chamber upright and position it using lifting equipment. After setup, configure the temperature and lighting parameters on the LCD controller and begin continuous operation for at least 180 hours.
Required Equipment: Suitable lifting equipment
- Confirm Installation Space
Confirm the installation space against the external dimensions of 830 x 850 x 1850 mm and ensure adequate clearance for ventilation and access. - Prepare Power Supply
Prepare the specified power supply of AC 220 V, 50 Hz with a capacity of 1200 W and verify that the outlet is grounded. - Unpack Chamber
Unpack the chamber carefully, keeping it upright at all times to avoid damaging the compressor and refrigeration system. - Position Chamber
Use suitable lifting equipment to position the chamber in the prepared installation space, ensuring all access points are clear. - Ensure Accessibility
Ensure that air inlets, test ports, shelving, drain areas, doors, and controller surfaces are accessible for cleaning and maintenance. - Set Operating Parameters
Set the desired temperature and lighting parameters using the LCD microcomputer controller with menu-based operation. - Begin Continuous Operation
Allow the chamber to operate continuously for at least 180 hours under proper installation conditions to stabilize the internal environment.
Why does the temperature range narrow from 4–50°C to 10–50°C when the light is on, and how should this affect experimental design?
The narrower range in illuminated mode occurs because the lighting system generates heat, preventing the chamber from reaching the same low temperatures as in no-light mode. For experiments requiring temperatures below 10°C, users should plan to operate without illumination or use supplementary external cooling.
Can this incubator be integrated with external monitoring or CO2 control for specialized applications like seed germination or cell culture?
Yes, optional accessories include an RS232/485 communication interface and software for data logging and remote monitoring, as well as a CO2 inlet and infrared CO2 controller for atmosphere supplementation. However, these functions are not standard and must be specified at ordering; the base configuration does not include active humidity control.
What are the continuous operation and installation requirements to maintain stable performance and avoid system overload?
The incubator is recommended for continuous operation of not less than 180 hours under proper installation conditions. It requires a 220 V, 50 Hz power supply rated at 1200 W, an ambient working environment of +5 to 30°C, and adequate space for the external dimensions of 830 x 850 x 1850 mm with accessible air inlets and ports for cleaning and maintenance.
The LCD Light Incubator 300 L (MGC-300A) provides 300 L capacity with 0–15000 lx six-step adjustable illumination, temperature range 4–50°C (no-light) / 10–50°C (illuminated), and 304 stainless steel interior. Its fluorine-free compressor-based cooling and optional communication, CO₂, and light-detection accessories support controlled incubation workflows in research and quality-control labs.
Positive
- Fluorine-free compressor cooling: Imported compressor and circulation-fan assembly with fluorine-free design supports efficient low-temperature operation and long service life, maintaining stable chamber recovery during repeated use.
- 304 stainless steel interior: Rounded corners and removable shelving improve cleaning efficiency and sample layout flexibility, supporting repeated hygiene and long-duration laboratory use.
Trade-offs
- No active humidity control: The unit does not include active humidity regulation; applications requiring specific humidity levels must rely on optional accessories or external conditioning.
- Requires 1200 W and dedicated space: The 1200 W power input and external dimensions of 830 x 850 x 1850 mm demand a prepared electrical supply and sufficient installation space, which may limit placement in crowded laboratories.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).