Programmable LCD Light Incubator, 250 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The incubator requires a stable AC 220V, 50Hz power supply and an ambient temperature between +5°C and 30°C. Continuous operation of at least 180 hours is recommended under proper installation to maintain thermal stability and compressor durability.
- Electrical Supply: Operate only on a grounded AC 220V, 50Hz circuit rated for at least 2000W to prevent electrical overload and ensure safe operation.
- Ambient Temperature: Maintain the working environment between +5°C and 30°C to avoid compressor strain and temperature control deviations.
- Continuous Operation: Schedule continuous operation periods of at least 180 hours to achieve stable chamber conditions and avoid thermal cycling effects.
- Over-Temperature Alarm: Verify the independent over-temperature alarm is functional before long-term use, as it will stop the unit and alert operators upon abnormal conditions.
- Handling and Positioning: Keep the unit upright during transport and use suitable lifting equipment due to its weight; ensure air inlets and test ports remain accessible for cleaning.
Begin by positioning the incubator in a suitable location with adequate ventilation and connecting it to the correct power supply. Then configure the lighting and temperature parameters via the LCD controller and verify safety systems before loading samples.
Required Equipment: Lifting equipment (e.g., forklift or pallet jack)
- Position the Incubator
Unpack the incubator and position it upright using suitable lifting equipment, ensuring the external dimensions allow for proper ventilation and access to the left-side test port. - Connect Power Supply
Connect the incubator to a dedicated AC 220V, 50Hz power outlet with a capacity of at least 2000W, and confirm the unit is grounded. - Install Shelves and Configure Lighting
Install the supplied shelves and select the desired lighting configuration (single-side, double-side, etc.) using the LCD menu interface. - Set Temperature and Program
Set the temperature range and program schedule via the LCD microcomputer controller, adjusting illumination intensity in six steps up to 12000 lx. - Verify Safety Systems
Enable the over-temperature alarm and verify its functionality by checking the alarm indicator on the controller. - Load Samples
Load samples onto the removable stainless steel shelves after confirming the chamber has reached the set temperature and lighting conditions.
What temperature range and uniformity can the MGC-250P programmable light incubator maintain in illuminated versus no-light operation?
In no-light mode the chamber controls from 4 to 50 °C; in illuminated mode the range shifts to 10 to 50 °C because of lighting heat input. Temperature resolution is 0.1 °C and temperature fluctuation/uniformity is ±1 °C.
Can this 250 L light incubator be configured with CO2 control or data-logging options for plant-growth experiments?
Yes—the chamber includes a left-side test port for measurement access, and optional accessories add RS232/485 communication interface and software, embedded printer, USB data storage, wireless alarm system, CO2 inlet, infrared CO2 controller, and light-intensity detection and control system. The base configuration does not state active humidity control, so confirm the exact accessory package before ordering.
What installation space, power supply, and handling conditions are required for the MGC-250P?
The chamber measures 760 x 815 x 1550 mm externally and requires a 2000 W AC 220 V, 50 Hz power supply; the specified working environment is +5 to 30 °C. Keep the packed unit upright and use suitable lifting equipment during unloading and positioning, and plan for continuous operation schedules of not less than 180 hours under proper installation conditions.
This 250L programmable light incubator offers fluorine-free cooling with an imported compressor, 304 stainless steel interior with rounded corners, and adjustable illumination up to 12000 lx, suitable for plant growth and microbial culture. However, it lacks active humidity control and has a temperature uniformity of ±1°C, which may limit precision applications requiring tighter environmental control.
Positive
- Fluorine-free cooling with imported compressor: The chamber uses a fluorine-free refrigeration system with an imported compressor and circulation fan, supporting efficient temperature control and long service life for reliable low-temperature performance.
- 304 stainless steel interior with rounded corners: The 304 stainless steel chamber interior features rounded corners and removable shelving, improving cleaning efficiency and sample layout flexibility for repeated laboratory use.
Trade-offs
- No active humidity control: This configuration does not include active humidity control, which may limit applications requiring precise relative humidity management, such as certain seed germination or insect rearing protocols.
- Temperature uniformity ±1°C: The specified temperature fluctuation and uniformity of ±1°C may be insufficient for highly sensitive experiments requiring tighter thermal stability, such as enzyme kinetics or precise microbial growth studies.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).