Programmable LCD Light Incubator, 150 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The chamber requires a stable ambient temperature of 5-30°C and a dedicated AC 220V, 50Hz power supply rated for 1750W. Continuous operation of at least 180 hours is recommended under proper installation conditions, with the over-temperature alarm providing automatic protection against abnormal conditions.
- Ambient Temperature Constraint: The unit must be operated within an ambient temperature range of +5 to 30°C to maintain specified temperature control performance.
- Power Supply Requirement: The incubator requires a grounded AC 220V, 50Hz power supply with a minimum capacity of 1750W.
- Continuous Operation Guidance: Continuous operation schedules of not less than 180 hours are recommended under proper installation conditions to ensure stability.
- Over-Temperature Alarm Protection: The independent over-temperature alarm stops the unit and alerts users when abnormal temperature conditions occur, reducing operational risk.
Position the incubator in a location meeting the external dimensions (690x800x1410 mm) and ambient temperature range (5-30°C). Connect to a grounded AC 220V, 50Hz power supply and configure the LCD controller for the desired temperature and light cycle.
Required Equipment: Lifting equipment
- Unpack the incubator
Unpack the incubator using suitable lifting equipment, keeping the chamber upright to avoid damage. - Position the chamber
Position the chamber in a location that meets the external dimensions of 690x800x1410 mm and an ambient temperature of 5 to 30°C. - Connect power supply
Connect the unit to a grounded AC 220V, 50Hz power supply rated for 1750W. - Configure controller
Configure the LCD microcomputer controller using the menu-based interface to set the desired temperature and light cycle parameters.
What is the temperature control range difference between no-light and illuminated modes for the AF-MLP0150 incubator, and how does that affect experimental planning?
The no-light mode range is 4°C to 50°C, while the illuminated mode range is 10°C to 50°C. This means that when lighting is active, the minimum achievable temperature is 10°C, which is 6°C higher than the no-light minimum. Researchers must account for this when designing protocols that require simultaneous low temperature and illumination, such as certain photoperiod studies.
What optional communication and data logging interfaces are available for the Atomfair MGC-100P incubator, and can they be integrated into existing laboratory monitoring systems?
The incubator supports optional RS232/485 communication interface and software, USB data storage, and an embedded printer. These allow direct connection to external computers for data logging and remote monitoring. Additionally, a wireless alarm system is available, enabling alerts without wired connections. Integration with existing systems is possible through these standard interfaces but must be specified at time of order.
What is the recommended continuous operation schedule and over-temperature protection for this light incubator?
The manufacturer recommends continuous operation schedules of not less than 180 hours under proper installation conditions to ensure stable performance. The unit includes independent over-temperature alarm protection that stops the unit and alerts users when abnormal temperature conditions occur, reducing risk to samples. Regular maintenance and accessibility to controller surfaces are advised.
This 150 L programmable light incubator offers a 304 stainless-steel chamber with LCD microcomputer control, temperature range of 4-50°C (no-light) and 10-50°C (illuminated), and six-step adjustable illumination up to 12000 lx, suitable for microbial culture, plant cultivation, and seed testing. The unit features fluorine-free cooling, over-temperature alarm, and optional accessories for communication and CO2 control, but lacks active humidity regulation and exhibits ±1°C temperature uniformity.
Positive
- 304 stainless-steel interior with rounded corners: The chamber interior is constructed from 304 stainless steel with rounded corners and removable shelving, facilitating efficient cleaning, chamber hygiene, and flexible sample layout during long-duration laboratory use.
- Programmable LCD control with six-step lighting: The LCD microcomputer controller enables menu-based operation and large-screen data display, while the six-step adjustable illumination (0–12000 lx) allows repeatable photoperiod and intensity control for plant-growth and light-dependent experiments.
Trade-offs
- Temperature uniformity ±1°C: The stated temperature fluctuation/uniformity of ±1°C imposes a limit on thermal precision, which may be insufficient for applications requiring tighter spatial or temporal temperature control.
- No active humidity control in this configuration: The product description explicitly states no active humidity control for this configuration, restricting its use in protocols that require regulated humidity levels alongside temperature and lighting.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).