150 L LCD light incubator with 4–50 °C no-light control, 10–50 °C illuminated operation, 0–12000 lx lighting, 304 stainless-steel interior and removable shelves.

SKU: AF-LE-E-MGLI-0150-M100
Category:
Brands:

LCD Light Incubator, 150 L
Research-grade laboratory product
Product Overview

LCD Light Incubator, 150 L is a LCD light incubator built for microbial culture, plant cultivation, seed testing, insect rearing and other light-controlled incubation workflows. This configuration provides 150 l chamber volume, No-light mode: 4 to 50 C; illuminated mode: 10 to 50 C, 0 to 12000 lx, six-step adjustable illumination, 304 stainless-steel chamber interior with removable shelving and lcd microcomputer controller with menu-based operation and large-screen data display for stable day-to-day laboratory operation.

This family uses fluorine-free design, imported compressor and fan components, stainless-steel interior construction, rounded internal corners, adjustable shelf spacing and a left-side test port for measurement access. The chamber combines imported compressor and circulation-fan assembly with microcomputer temperature-control system, 2 shelves and an interior size of 550 x 400 x 670 mm, supporting incubation, cultivation, climate simulation or conditioned test work where repeatable environmental control is important.

These LCD models are positioned for laboratories that need stable illuminated incubation with selectable single-side, double-side, three-side or partition lighting, plus optional communication, alarm and atmosphere-related accessories. Installation planning can be based on the external size of 690 x 800 x 1410 mm and the stated power requirement of 1500 W. Optional functions such as rs232/485 communication interface and software; embedded printer; usb data storage; wireless alarm system; co2 inlet; infrared co2 controller; light-intensity detection and control system allow the unit to be adapted for alarm notification, data output, programmable operation, atmosphere support or other application-specific requirements.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-MLI0150
Manufacturer Model MGC-100
Capacity 150 L
Temperature Control Range No-light mode: 4 to 50 C; illuminated mode: 10 to 50 C
Temperature Resolution 0.1 C
Temperature Fluctuation / Uniformity +/- 1 C
Humidity Function No active humidity control stated for this configuration
Lighting Configuration 0 to 12000 LX, six-step adjustable; single-side lighting; Lighting form varies by model and includes single-side, double-side, three-side or partition lighting
Controller LCD microcomputer controller with menu-based operation and large-screen data display
Chamber Material 304 stainless-steel chamber interior with removable shelving
Power / Input 1500 W
Power Supply AC 220 V, 50 Hz
Working Environment +5 to 30 C
Sensor Configuration microcomputer temperature-control system
Cooling System imported compressor and circulation-fan assembly
Continuous Operation Guidance Recommended for continuous operation schedules of not less than 180 hours under proper installation conditions
Internal Dimensions 550 x 400 x 670 mm
External Dimensions 690 x 800 x 1410 mm
Shelves / Light Decks 2 shelves
Program Function Standard LCD control for routine lighting and temperature operation
Optional Accessories and Functions RS232/485 communication interface and software; embedded printer; USB data storage; wireless alarm system; CO2 inlet; infrared CO2 controller; light-intensity detection and control system
Performance Features
  • LCD menu control and large-screen display keep temperature and lighting values visible during routine laboratory operation. This improves parameter review, setpoint editing and day-to-day operation in controlled chamber workflows.
  • Fluorine-free cooling design with imported compressor and fan components supports efficient chamber running and long service life. This helps maintain dependable low-temperature performance and stable chamber recovery during repeated use.
  • 304 stainless-steel interior construction with rounded corners and removable shelving helps improve cleaning efficiency and sample layout flexibility. This helps support repeated cleaning, chamber hygiene and long-duration laboratory use.
  • Model-specific lighting structures allow the user to match illumination intensity and distribution to cultivation depth and chamber size. This is valuable for plant-growth and photoperiod experiments that depend on repeatable lighting conditions.
  • Independent over-temperature alarm protection helps stop the unit and alert users when abnormal temperature conditions occur. This reduces operational risk by helping protect samples and notifying operators when abnormal conditions occur.
  • Optional communication, printing, USB storage, CO2 and light-detection functions extend the chamber for documented and application-specific workflows. This is valuable for plant-growth and photoperiod experiments that depend on repeatable lighting conditions.
APPLICATION SCOPE: Suitable for microbial culture, plant cultivation, seed testing, insect rearing and other light-controlled incubation workflows in universities, research institutes, pharmaceutical quality-control laboratories, agricultural research programs and industrial test environments that require controlled chamber operation.
HANDLING: Confirm installation space against 690 x 800 x 1410 mm, prepare the specified power supply, and keep air inlets, test ports, shelving, drain areas, doors and controller surfaces accessible for cleaning and maintenance. Every unit is shipped with reinforced packaging to reduce movement and impact during transport; keep the packed chamber upright and use suitable lifting equipment during unloading and positioning.
IMPORTANT NOTICE: Confirm the exact controller type, lighting form, humidity function, communication option and accessory package before ordering. Any displayed amount refers to the chamber body only and does not include freight. Freight is quoted separately and should be confirmed according to the delivery location and shipping method.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The chamber requires a stable working environment of 5–30°C and must be operated on a continuous schedule of at least 180 hours under proper installation conditions to maintain temperature stability. The over-temperature alarm will trigger a shutdown if abnormal conditions occur, requiring immediate operator intervention to protect samples.

  • Temperature Range Constraint: Temperature must be maintained within 4–50°C in no-light mode and 10–50°C in illuminated mode to avoid equipment damage or sample loss.
  • Power Supply Constraint: The unit requires a dedicated AC 220 V, 50 Hz power supply capable of delivering 1500 W to ensure stable compressor and fan operation.
  • Continuous Operation Requirement: Continuous operation schedules of at least 180 hours are recommended, and proper installation conditions must be verified to prevent drift or failure.
  • Accessibility Constraint: Air inlets, test ports, shelving, drain areas, doors, and controller surfaces must remain accessible for cleaning and maintenance to prevent overheating or contamination.
  • Over-Temperature Response: The independent over-temperature alarm will stop the unit and alert the operator when abnormal conditions occur, requiring immediate diagnosis and corrective action.

Confirm installation space against the external dimensions of 690 x 800 x 1410 mm and prepare the specified 220 V, 50 Hz power supply. Unpack the unit upright using suitable lifting equipment and position it with all air inlets and service panels accessible.

Required Equipment: Suitable lifting equipment (e.g., pallet jack or forklift)

  1. Confirm installation space
    Verify that the installation area accommodates the external dimensions of 690 x 800 x 1410 mm and allows clearance for air inlets and service access.
  2. Prepare the power supply
    Ensure a dedicated AC 220 V, 50 Hz outlet with 1500 W capacity is available and correctly grounded.
  3. Unpack the chamber upright
    Keep the packed chamber vertical during unpacking and use suitable lifting equipment to move it to the installation location.
  4. Position the chamber
    Place the unit on a level, stable surface, leaving all air inlets, test ports, drain areas, doors, and controller surfaces accessible for cleaning.
  5. Verify proper installation conditions
    Confirm that the working environment is between 5–30°C and that the unit is set for continuous operation of at least 180 hours to maintain stability.

Why does the temperature control range differ between no-light mode (4 to 50°C) and illuminated mode (10 to 50°C) on the Atomfair LCD Light Incubator 150 L?

The difference in minimum temperature arises because the illumination system generates heat, raising the chamber's baseline thermal load when lights are active. The no-light mode can reach 4°C, while illuminated mode is limited to 10°C due to this added heat. Temperature fluctuation and uniformity are maintained at ±1°C in both modes, as specified in the technical data.

What lighting configurations are available for the AF-MLI0150 LCD Light Incubator, and how do they support different incubation workflows?

The base configuration provides single-side lighting with six-step adjustable intensity from 0 to 12000 lx. The product description notes that lighting form varies by model and includes options for double-side, three-side, or partition lighting. These configurations allow users to match illumination distribution to cultivation depth and chamber size, which is critical for plant-growth and photoperiod experiments that depend on repeatable lighting conditions.

What are the continuous operation recommendations and installation requirements for the Atomfair LCD Light Incubator 150 L?

The incubator is recommended for continuous operation of at least 180 hours under proper installation conditions. Installation requires a space of 690 x 800 x 1410 mm, a dedicated AC 220V, 50 Hz, 1500 W power supply, and an ambient temperature range of +5 to 30°C. The unit uses a fluorine-free cooling system with imported compressor and fan components for efficient long-term operation, and air inlets and test ports must remain accessible for cleaning and maintenance.

The LCD Light Incubator (150L) offers a 304 stainless-steel chamber with fluorine-free cooling and adjustable illumination up to 12000 lx, suitable for microbial and plant cultivation. However, the ±1°C temperature uniformity and lack of active humidity control impose operational constraints for precision-sensitive or humidity-dependent workflows.

Positive

  • Fluorine-free cooling with imported compressor: Efficient, long service life, and stable low-temperature performance due to the fluorine-free design and imported compressor and fan components.
  • 304 stainless steel interior with rounded corners: Enhances cleaning efficiency and sample layout flexibility with removable shelving, supporting repeated laboratory use and hygiene.

Trade-offs

  • Limited temperature uniformity: Temperature fluctuation and uniformity of ±1°C may require careful sample placement for workflows sensitive to spatial temperature gradients.
  • No integrated humidity control: Absence of active humidity regulation limits applicability for experiments requiring precise moisture conditioning, such as seed germination or fungal studies.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).