This climate chamber requires a stable power supply and ambient temperature within 5–30°C for safe operation. Improper installation or obstructed ventilation may cause equipment damage or safety hazards.
- Power Supply Requirement: The chamber must be connected to a dedicated AC 220V, 50Hz power supply with a capacity of 2050 W and proper grounding.
- Ambient Temperature Range: The operating environment must maintain an ambient temperature between 5°C and 30°C.
- Transport Orientation: The chamber must be kept upright during transport and unpacking to prevent damage to the refrigeration system.
- Ventilation Clearance: Air inlets, exhaust paths, and all external vents must remain unobstructed to ensure proper cooling and airflow.
- Safety System Verification: Over-limit protection and wireless alarm systems should be verified functional before unattended long-duration runs.
Initialize the chamber by verifying installation space, power supply, and ventilation accessibility. Program the controller for the desired environmental cycles before starting continuous operation.
Required Equipment: Suitable lifting equipment
- Unpack and Position Chamber
Keep the packed chamber upright and use suitable lifting equipment to move it to the installation site. - Verify Installation Space
Confirm that the installation space accommodates the external dimensions of 950 x 850 x 1850 mm with adequate clearance for ventilation. - Connect Power Supply
Prepare and connect a dedicated AC 220V, 50Hz power supply with the required 2050 W capacity and proper grounding. - Ensure Ventilation Accessibility
Ensure that air inlets, exhaust paths, shelves, ports, doors, and control interfaces remain accessible for cleaning and maintenance. - Program Controller
Program the controller with the desired temperature, humidity, light intensity, and time segments for up to 30 programmed cycles. - Verify Safety Systems
Verify that all over-limit protection and wireless alarm systems are functional before starting an unattended run.
What temperature and humidity performance can the Atomfair AF-MPH0450 450 L artificial climate chamber maintain during lighted plant-growth runs?
With lighting active, the chamber controls temperature from 10 to 50 °C; without lighting, the range extends to 0 to 50 °C. Temperature fluctuation/uniformity is ±1 °C with 0.1 °C resolution, and humidity is controllable from 50%RH to 90%RH with a deviation of ±5%RH to 7%RH. Illumination is adjustable from 0 to 25000 lx in six steps.
What installation space, power supply, and ambient conditions are required for the AF-MPH0450?
The chamber requires an installation footprint based on external dimensions of 950 x 850 x 1850 mm and a 2050 W electrical supply at AC 220 V, 50 Hz. It is designed to operate in a working environment of +5 to 30 °C, and the supplier advises confirming installation space and keeping air inlets, exhaust paths, shelves, ports, doors, and control interfaces accessible for maintenance.
Can the AF-MPH0450 be configured for CO2 atmosphere control and external data logging for long-term plant studies?
Yes, the chamber can be ordered with an infrared CO2 sensor package or infrared CO2 controller plus a CO2 inlet for atmosphere-control configurations. Optional RS485 or USB communication and software, embedded printer, USB data storage, and wireless alarm system support data logging and unattended-run monitoring.
This 450 L artificial climate chamber features dual imported compressors with automatic alternating operation for extended run stability and high-intensity programmable lighting up to 25000 lx in a three-side configuration, but its temperature range is limited to 10–50°C when lighting is active and humidity deviation of ±5–7%RH may constrain precision applications.
Positive
- Dual Compressor Alternating Operation: Two imported compressors automatically alternate to support long-duration, continuous cultivation programs without single-unit overwork, improving reliability during extended climate simulations.
- High-Intensity Three-Side Lighting: Six-step adjustable illumination up to 25000 lx with three-side LED arrays provides uniform light distribution across the 450 L chamber, enabling repeatable photoperiod protocols for demanding plant growth studies.
Trade-offs
- Lighting Restricts Low-Temperature Range: When lighting is active, the temperature control range is limited to 10–50°C; without lighting it can reach 0°C. This trade-off must be considered for protocols requiring simultaneous low temperature and illumination.
- Moderate Humidity Deviation Band: The humidity control deviation of ±5 to ±7% RH is relatively wide for applications requiring tight moisture regulation, such as certain seed germination or material stability tests.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.