High-Intensity Light Incubator 800 L, 0-50°C ATOMFAIR®

$18,000.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

800 L programmable light incubator with 0-50 °C control, 0-30000 lx illumination, 0.1 °C resolution, 30 program segments and 2700 W power. Order now.

SKU: AF-LE-E-M2HP-0800-BP80
Category:
Brands:

High-Intensity Programmable Light Incubator, 800 L
Research-grade laboratory product
Product Overview

High-Intensity Programmable Light Incubator, 800 L is a high-intensity programmable light incubator or artificial climate chamber designed for plant growth, agricultural cultivation, seedling studies and climate-controlled biological test programs. This configuration offers 800 l working volume, With lighting: 10 to 50 C; without lighting: 0 to 50 C, 0 to 30000 lx, six-step adjustable lighting, mirror-finish stainless-steel chamber interior and programmable controller for temperature, light, humidity and time steps for controlled laboratory operation.

The series is described around stronger illumination, long-duration running and programmable environmental control, with multiple lighting forms available from single-side to partition-style arrangements. The chamber uses dual imported compressors with automatic alternating operation together with infrared CO2 sensor package available for atmosphere-control configurations, 3 shelves, helping the unit fit continuous cultivation, incubation, climate simulation or stability workflows where repeatable environmental control matters.

This family is appropriate when higher light levels and longer cultivation cycles are more important than compact footprint, especially in plant growth and advanced climate-simulation programs. Installation planning can be based on the external size of 1475 x 890 x 1780 mm with power requirement 2700 W. Optional functions such as rs485 or usb communication and software; embedded printer; usb data storage; wireless alarm system; co2 inlet; infrared co2 controller; partition lighting system allow the chamber to be configured for data logging, alarm notification, atmosphere support and application-specific monitoring.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-MPB0800
Capacity 800 L
Temperature Control Range With lighting: 10 to 50 C; without lighting: 0 to 50 C
Temperature Resolution 0.1 C
Temperature Fluctuation / Uniformity +/- 1 C
Humidity Function No active humidity control stated for this configuration
Humidity Deviation +/- 5%RH to 7%RH
Lighting Configuration 0 to 30000 LX, six-step adjustable; partition lighting, two layers; single-side, three-side or partition lighting depending on model volume and chamber form
Controller programmable controller for temperature, light, humidity and time steps
Chamber Material mirror-finish stainless-steel chamber interior
Power / Input 2700 W
Power Supply AC 220 V, 50 Hz
Working Environment +5 to 30 C
Sensor Configuration infrared CO2 sensor package available for atmosphere-control configurations
Cooling System dual imported compressors with automatic alternating operation
Internal Dimensions 800 x 590 x 1650 mm
External Dimensions 1475 x 890 x 1780 mm
Shelves / Light Decks 3 shelves
Program Function temperature, humidity, light intensity and time can be set independently across 30 programmed segments
Optional Accessories and Functions RS485 or USB communication and software; embedded printer; USB data storage; wireless alarm system; CO2 inlet; infrared CO2 controller; partition lighting system
Performance Features
  • High-intensity lighting configurations deliver a broader chamber-illumination range for demanding plant-growth protocols. This supports plant-growth or climate-chamber work that depends on repeatable illumination conditions.
  • Programmable control simplifies complex day-night or staged environmental cycles. This supports more reliable day-to-day laboratory use in plant growth, agricultural cultivation, seedling studies and climate-controlled biological test programs.
  • Imported compressors and long-running refrigeration strategy support stable operation during extended cultivation programs. This supports dependable low-temperature performance and long-duration running stability.
  • Wireless alarm, fault display and over-limit protection help maintain sample safety in unattended runs. This helps protect samples and alert operators when abnormal conditions appear.
  • Optional CO2 monitoring and control can be added where plant-growth atmosphere support is needed. This helps expand the chamber for advanced cultivation programs that require atmosphere management.
  • Partition lighting options improve use of vertical space while keeping cultivation layers independently illuminated. This supports plant-growth or climate-chamber work that depends on repeatable illumination conditions.
APPLICATION SCOPE: Suitable for plant growth, agricultural cultivation, seedling studies and climate-controlled biological test programs in universities, research institutes, pharmaceutical quality-control laboratories, agricultural research programs and industrial test environments that require controlled chamber operation.
HANDLING: Confirm installation space against 1475 x 890 x 1780 mm, prepare the stated power supply, and keep air inlets, exhaust paths, shelves, ports, doors and control interfaces accessible for cleaning and maintenance. Every unit is shipped with reinforced packaging to reduce movement and impact during transport; keep the packed chamber upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select the required controller, lighting, humidity, communication and optional accessory configuration before ordering. Any displayed amount refers to the chamber body only and does not include freight. Freight is quoted separately and should be confirmed with shipping details.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The unit requires a dedicated AC 220 V, 50 Hz power supply with a 2700 W capacity. The operating environment must be maintained between 5 and 30 °C with adequate ventilation for the dual-compressor cooling system.

  • Installation Space and Ventilation: The external dimensions of 1475 x 890 x 1780 mm require sufficient clearance for air inlets and exhaust paths, and the unit must be kept upright during transport.
  • Electrical Supply Requirements: The incubator must be connected to a dedicated AC 220 V, 50 Hz circuit capable of delivering 2700 W to prevent tripping or voltage drop.
  • Ambient Temperature Limits: The ambient temperature must remain between 5 and 30 °C to ensure proper cooling system operation and temperature control accuracy.
  • Over-Limit and Alarm Verification: Verify that the over-limit protection and wireless alarm functions are operational before unattended operation to ensure sample safety.
  • Handling and Lifting: Use suitable lifting equipment when moving the packed unit and keep it upright to avoid damage to the compressors and internal components.

Follow these steps to safely install the unit and prepare it for first use. Ensure all connections and settings are verified before loading samples.

Required Equipment: Lifting equipment (e.g., pallet jack or forklift)

  1. Confirm installation space
    Confirm installation space against the external dimensions of 1475 x 890 x 1780 mm and ensure the area provides adequate ventilation for the dual-compressor cooling system.
  2. Prepare power supply
    Prepare the power supply by verifying the outlet provides AC 220 V, 50 Hz with sufficient capacity for 2700 W.
  3. Inspect and unpack
    Inspect the unit for shipping damage upon arrival and remove the reinforced packaging while keeping the chamber upright.
  4. Position the unit
    Position the chamber so that air inlets and exhaust remain unobstructed and all interfaces are accessible for cleaning and maintenance.
  5. Connect power
    Connect the power cord to the dedicated outlet and power on the unit to verify the controller display activates.
  6. Set program parameters
    Set the desired temperature, light intensity, and time program using the programmable controller, following the manufacturer's instructions.
  7. Stabilize before use
    Allow the chamber to stabilize at the set conditions before loading samples.

How does the lighting affect the temperature control range on the Atomfair AF-MPB0800 800L incubator?

The temperature control range depends on whether the lighting is active. With lighting on, the range is 10 to 50 °C; without lighting, it extends to 0 to 50 °C. The chamber provides six-step adjustable lighting up to 30,000 lx, and the dual imported compressors with automatic alternating operation maintain stable temperature during long-duration runs.

Can the Atomfair AF-MPB0800 incubator support CO2 monitoring and control for plant growth applications?

Yes, the incubator can be configured with an optional infrared CO2 sensor package and CO2 inlet for atmosphere control. The programmable controller allows independent setting of temperature, humidity, light intensity, and time across 30 programmed segments, making it suitable for advanced plant growth protocols that require CO2 management.

What are the installation and power requirements for the 800 L Atomfair light incubator?

The unit requires a 2700W power supply at AC 220 V, 50 Hz, and an ambient working environment of +5 to 30 °C. External dimensions are 1475 x 890 x 1780 mm, so adequate space and ventilation must be ensured. The dual imported compressors with automatic alternating operation support long-duration stability, and the chamber should be kept upright during transport with suitable lifting equipment.

The 800 L High-Intensity Programmable Light Incubator delivers 0–30000 lx illumination with six-step adjustability and dual alternating compressors for stable long-duration operation, but lacks active humidity control and requires 2700 W power plus a 1475 x 890 x 1780 mm footprint, making it best suited for dedicated plant-growth or climate-simulation labs where precise humidity is not critical.

Positive

  • High-intensity programmable lighting: Illumination range of 0 to 30000 lx with six-step adjustment and optional partition lighting supports repeatable photoperiods and vertical light distribution for demanding plant-growth protocols.
  • Dual alternating compressors: Two imported compressors operate automatically in alternating duty cycles, enabling stable long-duration refrigeration and extended cultivation runs without single-point cooling failure.

Trade-offs

  • No active humidity control: The configuration does not provide active humidity regulation; only a passive humidity deviation range (±5%RH to 7%RH) is specified, which limits use in applications requiring precise moisture management.
  • High power and space requirements: The unit draws 2700 W and measures 1475 x 890 x 1780 mm externally, demanding dedicated power circuitry and a stable installation area with adequate ventilation within a +5 to 30 °C ambient environment.