Programmable Climate Chamber 800 L 0-50°C ATOMFAIR®

$23,000.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 800 L artificial climate chamber with 0–50°C temperature control, 50–90%RH humidity, 42,000 lx LED lighting and 30 programmable segments.

SKU: AF-LE-E-M2LP-0800-H800
Category:
Brands:

Programmable Artificial Climate Chamber, 800 L
Research-grade laboratory product
Product Overview

Programmable Artificial Climate Chamber, 800 L is a programmable LED light incubator or artificial climate chamber designed for plant growth, tissue culture, seed germination, insect culture, BOD work and climate-controlled biological cultivation. This configuration offers 800 l working volume, With lighting: 10 to 50 C; without lighting: 0 to 50 C, 50%rh to 90%rh humidity capability, 0 to 42000 lx, six-step adjustable lighting, mirror-finish stainless-steel chamber interior and programmable controller with multi-segment temperature, humidity, light and time setting for controlled laboratory operation.

This long-duration programmable family is positioned for cultivation programs that require stable running over weeks or months, using imported compressors, mirror-finish chamber construction and a circulation-air layout that limits direct draft on plants. The chamber uses two imported compressors with alternating long-duration operation design together with infrared CO2 sensor when the optional atmosphere-control package is selected, 3 shelves, helping the unit fit continuous cultivation, incubation, climate simulation or stability workflows where repeatable environmental control matters.

The family is designed for cultivation work that benefits from adjustable lighting levels, programmable climate changes and optional alarm, communication or CO2 functions without exposing pricing or source-notes in the public page. Installation planning can be based on the external size of 1475 x 890 x 1780 mm with power requirement 2800 W. Optional functions such as rs485 or 232 communication interface and software; embedded printer; usb data storage; wireless alarm system; co2 inlet; infrared co2 controller; lighting control system allow the chamber to be configured for data logging, alarm notification, atmosphere support and application-specific monitoring.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-M2H0800
Capacity 800 L
Temperature Control Range With lighting: 10 to 50 C; without lighting: 0 to 50 C
Temperature Resolution 0.1 C
Temperature Fluctuation / Uniformity +/- 1 C
Humidity Function 50%RH to 90%RH
Humidity Deviation +/- 5%RH to 7%RH
Lighting Configuration 0 to 42000 LX, six-step adjustable; daylight-lamp partition lighting; family lighting configurations range from top-mounted LED lighting to three-side and partition lighting systems
Controller programmable controller with multi-segment temperature, humidity, light and time setting
Chamber Material mirror-finish stainless-steel chamber interior
Power / Input 2800 W
Power Supply AC 220 V, 50 Hz
Working Environment +5 to 30 C
Sensor Configuration infrared CO2 sensor when the optional atmosphere-control package is selected
Cooling System two imported compressors with alternating long-duration operation design
Internal Dimensions 800 x 590 x 1650 mm
External Dimensions 1475 x 890 x 1780 mm
Shelves / Light Decks 3 shelves
Program Function 30 program segments, each with time setting from 1 minute to 99 hours 59 minutes
Optional Accessories and Functions RS485 or 232 communication interface and software; embedded printer; USB data storage; wireless alarm system; CO2 inlet; infrared CO2 controller; lighting control system
Performance Features
  • Long-duration running design uses imported compressors that automatically alternate to support continuous chamber operation. This supports dependable low-temperature performance and long-duration running stability.
  • Programmable control can set temperature, humidity, light intensity and time independently in multi-step processes. This helps improve environmental tracking for incubation, cultivation and stability-study workflows.
  • LED lighting is available in multiple chamber layouts, from top-mounted lighting to three-side or partition-style designs. This supports plant-growth or climate-chamber work that depends on repeatable illumination conditions.
  • Wireless alarm and fault-display functions help operators respond quickly when abnormal conditions appear. This helps protect samples and alert operators when abnormal conditions appear.
  • Optional CO2 inlet and infrared CO2 controller support specialized plant-growth workflows. This helps operators review setpoints, trends and alarms more efficiently during routine operation.
  • RS485 or 232 communication, USB export and printer options help create operation records and trend review. This supports more reliable day-to-day laboratory use in plant growth, tissue culture, seed germination, insect culture, BOD work and climate-controlled biological cultivation.
APPLICATION SCOPE: Suitable for plant growth, tissue culture, seed germination, insect culture, BOD work and climate-controlled biological cultivation in universities, research institutes, pharmaceutical quality-control laboratories, agricultural research programs and industrial test environments that require controlled chamber operation.
HANDLING: Confirm installation space against 1475 x 890 x 1780 mm, prepare the stated power supply, and keep air inlets, exhaust paths, shelves, ports, doors and control interfaces accessible for cleaning and maintenance. Every unit is shipped with reinforced packaging to reduce movement and impact during transport; keep the packed chamber upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select the required controller, lighting, humidity, communication and optional accessory configuration before ordering. Any displayed amount refers to the chamber body only and does not include freight. Freight is quoted separately and should be confirmed with shipping details.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This document defines installation, electrical, environmental, and transport constraints for the Atomfair Programmable Artificial Climate Chamber 800 L (model AF-M2H0800). Operators must maintain the specified working environment and power supply and keep the unit upright during handling.

  • Installation Space: Confirm the installation location accommodates the 1475 x 890 x 1780 mm external dimensions with accessible air inlets, exhaust paths, shelves, ports, doors, and control interfaces.
  • Power Supply: Connect the chamber only to an AC 220 V, 50 Hz supply rated for the 2800 W input requirement.
  • Working Environment: Operate the chamber only within the stated +5 to 30 C working environment to maintain specified performance.
  • Transport Orientation: Keep the packed chamber upright and use suitable lifting equipment to reduce movement and impact during transport.
  • Maintenance Access: Keep air inlets, exhaust paths, shelves, ports, doors, and control interfaces accessible for cleaning and maintenance.

This procedure covers receiving, positioning, connecting, and preparing the Atomfair Programmable Artificial Climate Chamber 800 L for operation. Follow these steps to avoid transport damage and ensure the unit is ready for controlled cultivation.

Required Equipment: Suitable lifting equipment

  1. Confirm Installation Space
    Confirm the installation space accommodates the chamber's 1475 x 890 x 1780 mm external dimensions with clearance for air inlets and exhaust paths.
  2. Prepare Power Supply
    Verify a dedicated AC 220 V, 50 Hz power outlet rated for 2800 W is available before moving the chamber into place.
  3. Move Chamber Upright
    Move the packed chamber upright using suitable lifting equipment to reduce movement and impact during transport.
  4. Position Chamber
    Position the chamber in the prepared location while keeping shelves, ports, doors, and control interfaces accessible.
  5. Connect Power
    Connect the chamber to the prepared AC 220 V, 50 Hz power supply after confirming the working environment is within +5 to 30 C.
  6. Set Program
    Set the multi-segment temperature, humidity, light, and time program as required for the cultivation workflow.
  7. Verify Operation
    Verify air inlets and exhaust paths remain unobstructed before starting long-duration operation.

How does the alternating dual-compressor design improve long-duration stability in the 800 L programmable climate chamber?

The chamber uses two imported compressors that automatically alternate operation to support continuous long-duration running. This design enhances low-temperature performance and running stability over weeks or months, which is critical for cultivation programs requiring repeatable environmental control without compressor fatigue or single-point failure.

Can the Atomfair AF-M2H0800 climate chamber support CO2 enrichment for plant growth or tissue culture applications?

Yes, the chamber supports optional CO2 inlet and an infrared CO2 controller as part of the atmosphere-control package. When selected, an infrared CO2 sensor is integrated, allowing precise setpoint monitoring and enrichment for specialized plant-growth or tissue-culture workflows requiring controlled CO2 levels.

What are the critical installation requirements for the 800 L programmable artificial climate chamber?

The chamber requires an installation space accommodating external dimensions of 1475 x 890 x 1780 mm and a dedicated power supply of AC 220 V, 50 Hz at 2800 W. The working environment must be between +5 to 30 °C, and air inlets, exhaust paths, shelves, ports, and control interfaces must remain accessible for cleaning and maintenance.

This 800 L programmable artificial climate chamber offers dual alternating compressors for long-duration stability, programmable multi-segment control of temperature, humidity, light, and time, plus optional CO2 and communication interfaces. Operational constraints include temperature fluctuation of ±1°C, humidity deviation of ±5–7% RH, and a power requirement of 2800 W at 220 V/50 Hz.

Positive

  • Dual alternating compressors for long-duration running: Two imported compressors automatically alternate to support continuous operation, enhancing reliability for extended cultivation or incubation programs.
  • Programmable multi-segment control: Up to 30 program segments allow independent setting of temperature, humidity, light intensity, and time, enabling precise environmental tracking for complex protocols.

Trade-offs

  • Temperature fluctuation and uniformity limits: Specified temperature fluctuation/uniformity of ±1°C and humidity deviation of ±5–7% RH may constrain applications requiring tighter control tolerances.
  • High power and infrastructure requirements: Requires 2800 W at AC 220 V, 50 Hz and a working environment of +5 to 30°C, necessitating dedicated electrical and HVAC planning for installation.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).