Programmable Climate Chamber 300 L 0-50°C ATOMFAIR®

$12,500.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

300 L programmable climate chamber with 0-50 °C control, 50-90%RH humidity, 0-28000 lx LED lighting and 30-segment programming for plant growth. Order now.

SKU: AF-LE-E-M2LP-0300-H350
Category:
Brands:

Programmable Artificial Climate Chamber, 300 L
Research-grade laboratory product
Product Overview

Programmable Artificial Climate Chamber, 300 L is a programmable LED light incubator or artificial climate chamber designed for plant growth, tissue culture, seed germination, insect culture, BOD work and climate-controlled biological cultivation. This configuration offers 300 l working volume, With lighting: 10 to 50 C; without lighting: 0 to 50 C, 50%rh to 90%rh humidity capability, 0 to 28000 lx, six-step adjustable lighting, mirror-finish stainless-steel chamber interior and programmable controller with multi-segment temperature, humidity, light and time setting for controlled laboratory operation.

This long-duration programmable family is positioned for cultivation programs that require stable running over weeks or months, using imported compressors, mirror-finish chamber construction and a circulation-air layout that limits direct draft on plants. The chamber uses two imported compressors with alternating long-duration operation design together with infrared CO2 sensor when the optional atmosphere-control package is selected, 3 shelves, helping the unit fit continuous cultivation, incubation, climate simulation or stability workflows where repeatable environmental control matters.

The family is designed for cultivation work that benefits from adjustable lighting levels, programmable climate changes and optional alarm, communication or CO2 functions without exposing pricing or source-notes in the public page. Installation planning can be based on the external size of 830 x 850 x 1850 mm with power requirement 1700 W. Optional functions such as rs485 or 232 communication interface and software; embedded printer; usb data storage; wireless alarm system; co2 inlet; infrared co2 controller; lighting control system allow the chamber to be configured for data logging, alarm notification, atmosphere support and application-specific monitoring.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-M2H0300
Capacity 300 L
Temperature Control Range With lighting: 10 to 50 C; without lighting: 0 to 50 C
Temperature Resolution 0.1 C
Temperature Fluctuation / Uniformity +/- 1 C
Humidity Function 50%RH to 90%RH
Humidity Deviation +/- 5%RH to 7%RH
Lighting Configuration 0 to 28000 LX, six-step adjustable; LED three-side lighting; family lighting configurations range from top-mounted LED lighting to three-side and partition lighting systems
Controller programmable controller with multi-segment temperature, humidity, light and time setting
Chamber Material mirror-finish stainless-steel chamber interior
Power / Input 1700 W
Power Supply AC 220 V, 50 Hz
Working Environment +5 to 30 C
Sensor Configuration infrared CO2 sensor when the optional atmosphere-control package is selected
Cooling System two imported compressors with alternating long-duration operation design
Internal Dimensions 520 x 550 x 1140 mm
External Dimensions 830 x 850 x 1850 mm
Shelves / Light Decks 3 shelves
Program Function 30 program segments, each with time setting from 1 minute to 99 hours 59 minutes
Optional Accessories and Functions RS485 or 232 communication interface and software; embedded printer; USB data storage; wireless alarm system; CO2 inlet; infrared CO2 controller; lighting control system
Performance Features
  • Long-duration running design uses imported compressors that automatically alternate to support continuous chamber operation. This supports dependable low-temperature performance and long-duration running stability.
  • Programmable control can set temperature, humidity, light intensity and time independently in multi-step processes. This helps improve environmental tracking for incubation, cultivation and stability-study workflows.
  • LED lighting is available in multiple chamber layouts, from top-mounted lighting to three-side or partition-style designs. This supports plant-growth or climate-chamber work that depends on repeatable illumination conditions.
  • Wireless alarm and fault-display functions help operators respond quickly when abnormal conditions appear. This helps protect samples and alert operators when abnormal conditions appear.
  • Optional CO2 inlet and infrared CO2 controller support specialized plant-growth workflows. This helps operators review setpoints, trends and alarms more efficiently during routine operation.
  • RS485 or 232 communication, USB export and printer options help create operation records and trend review. This supports more reliable day-to-day laboratory use in plant growth, tissue culture, seed germination, insect culture, BOD work and climate-controlled biological cultivation.
APPLICATION SCOPE: Suitable for plant growth, tissue culture, seed germination, insect culture, BOD work and climate-controlled biological cultivation in universities, research institutes, pharmaceutical quality-control laboratories, agricultural research programs and industrial test environments that require controlled chamber operation.
HANDLING: Confirm installation space against 830 x 850 x 1850 mm, prepare the stated power supply, and keep air inlets, exhaust paths, shelves, ports, doors and control interfaces accessible for cleaning and maintenance. Every unit is shipped with reinforced packaging to reduce movement and impact during transport; keep the packed chamber upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select the required controller, lighting, humidity, communication and optional accessory configuration before ordering. Any displayed amount refers to the chamber body only and does not include freight. Freight is quoted separately and should be confirmed with shipping details.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This document specifies the environmental and technical constraints for operating the Atomfair AF-M2H0300 programmable artificial climate chamber. Adherence to these parameters ensures reliable performance and sample integrity.

  • Temperature operating range: Operate the chamber with lighting only between 10 °C and 50 °C, and without lighting between 0 °C and 50 °C.
  • Humidity operating range: Maintain humidity setpoints between 50 %RH and 90 %RH to stay within the specified deviation of ±5 %RH to ±7 %RH.
  • Working environment temperature: Ensure the ambient working environment temperature stays between +5 °C and 30 °C for proper compressor and controller function.
  • Power supply requirement: Provide a dedicated AC 220 V, 50 Hz power supply capable of delivering 1700 W to the chamber.
  • Air circulation clearance: Keep air inlets, exhaust paths, shelves, ports, doors, and control interfaces accessible to allow unobstructed air circulation and maintenance.

Follow these steps to install and set up the Atomfair AF-M2H0300 climate chamber for controlled biological cultivation. Proper installation ensures stable environmental control and safe operation.

Required Equipment: suitable lifting equipment

  1. Confirm installation space
    Confirm that the installation space accommodates the external dimensions of 830 × 850 × 1850 mm with accessible clearances.
  2. Prepare power supply
    Prepare a dedicated AC 220 V, 50 Hz power supply rated for 1700 W near the installation location.
  3. Position and unpack chamber
    Keep the packed chamber upright and use suitable lifting equipment to move it to the installation site, then unpack carefully.
  4. Connect power and verify environment
    Connect the chamber to the prepared power supply and verify that the ambient temperature is between +5 °C and 30 °C.
  5. Configure programmable controller
    Set the programmable controller with the desired temperature, humidity, light intensity, and time parameters for the multi-step cultivation program.

What is the temperature uniformity and fluctuation of the Atomfair AF-M2H0300 climate chamber?

The temperature uniformity and fluctuation is ±1°C across the 300 L working volume. This specification applies to the entire controlled range: with lighting (10 to 50°C) and without lighting (0 to 50°C). The chamber achieves this using two alternating imported compressors and a circulation-air layout that limits direct draft on samples.

Does the AF-M2H0300 support CO2 control for plant growth or tissue culture experiments?

Yes, CO2 control is available as an optional package. The chamber can be configured with a CO2 inlet and an infrared CO2 controller integrated with the programmable system. When this option is selected, the infrared CO2 sensor provides feedback for maintaining setpoint concentrations during long-duration cultivation or climate simulation.

What power supply and installation space are required for the Atomfair AF-M2H0300 climate chamber?

The chamber requires a 1700 W power supply at AC 220 V, 50 Hz. External dimensions are 830 x 850 x 1850 mm, so installation space must accommodate these footprints with access for air inlets, exhaust paths, doors, and control interfaces. Confirm power supply availability and clearance before installation.

The Atomfair AF-M2H0300 300 L programmable artificial climate chamber provides dual-imported-compressor alternating operation for sustained long-duration stability, a full-range programmable controller (30 segments) for multi-parameter cycling of temperature, humidity, and six-step LED illumination, and optional infrared CO2 control; however, the ±1 °C temperature uniformity, ±5–7% RH humidity deviation, and 1700 W continuous power draw impose planning constraints for sensitive assays and facility infrastructure.

Positive

  • Alternating dual-compressor long-run stability: Two imported compressors alternate operation to support continuous chamber use over weeks or months, reducing single-point fatigue and improving low-temperature reliability for extended cultivation or stability studies.
  • Multi-segment programmable climate cycling: Up to 30 independent program segments allow time-based sequencing of temperature (0–50 °C), humidity (50–90% RH), and six-step LED light intensity (0–28,000 lx), enabling reproducible diurnal or multi-phase incubation protocols.

Trade-offs

  • Moderate temperature uniformity tolerance: Specified temperature fluctuation and uniformity of ±1 °C may limit suitability for applications requiring ultra-tight thermal gradients, such as certain enzymatic or material-stability assays, within the 300 L volume.
  • High continuous power consumption: The 1700 W power rating and reliance on dual compressors for long-duration operation require dedicated circuit capacity (220 V, 50 Hz) and raise operational energy costs for continuous use in shared lab spaces.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).