Programmable LED Light Incubator 1500 L ATOMFAIR®

$35,000.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade programmable LED light incubator, 1500 L, with 10 to 50 C operation, 0 to 55000 lx lighting, 30-segment control. Order now.

SKU: AF-LE-E-M2LP-1500-B150
Category:
Brands:

Programmable LED Light Incubator, 1500 L
Research-grade laboratory product
Product Overview

Programmable LED Light Incubator, 1500 L is a programmable LED light incubator or artificial climate chamber designed for plant growth, tissue culture, seed germination, insect culture, BOD work and climate-controlled biological cultivation. This configuration offers 1500 l working volume, With lighting: 10 to 50 C; without lighting: 0 to 50 C, 0 to 55000 lx, six-step adjustable lighting, mirror-finish stainless-steel chamber interior and programmable controller with multi-segment temperature, humidity, light and time setting for controlled laboratory operation.

This long-duration programmable family is positioned for cultivation programs that require stable running over weeks or months, using imported compressors, mirror-finish chamber construction and a circulation-air layout that limits direct draft on plants. The chamber uses two imported compressors with alternating long-duration operation design together with infrared CO2 sensor when the optional atmosphere-control package is selected, 4 shelves, helping the unit fit continuous cultivation, incubation, climate simulation or stability workflows where repeatable environmental control matters.

The family is designed for cultivation work that benefits from adjustable lighting levels, programmable climate changes and optional alarm, communication or CO2 functions without exposing pricing or source-notes in the public page. Installation planning can be based on the external size of 1570 x 1475 x 2050 mm with power requirement 4300 W. Optional functions such as rs485 or 232 communication interface and software; embedded printer; usb data storage; wireless alarm system; co2 inlet; infrared co2 controller; lighting control system allow the chamber to be configured for data logging, alarm notification, atmosphere support and application-specific monitoring.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-M2B1500
Capacity 1500 L
Temperature Control Range With lighting: 10 to 50 C; without lighting: 0 to 50 C
Temperature Resolution 0.1 C
Temperature Fluctuation / Uniformity +/- 1 C
Humidity Function No active humidity control stated for this configuration
Humidity Deviation +/- 5%RH to 7%RH
Lighting Configuration 0 to 55000 LX, six-step adjustable; daylight-lamp partition lighting; family lighting configurations range from top-mounted LED lighting to three-side and partition lighting systems
Controller programmable controller with multi-segment temperature, humidity, light and time setting
Chamber Material mirror-finish stainless-steel chamber interior
Power / Input 4300 W
Power Supply AC 220 V, 50 Hz
Working Environment +5 to 30 C
Sensor Configuration infrared CO2 sensor when the optional atmosphere-control package is selected
Cooling System two imported compressors with alternating long-duration operation design
Internal Dimensions 1550 x 590 x 1650 mm
External Dimensions 1570 x 1475 x 2050 mm
Shelves / Light Decks 4 shelves
Program Function 30 program segments, each with time setting from 1 minute to 99 hours 59 minutes
Optional Accessories and Functions RS485 or 232 communication interface and software; embedded printer; USB data storage; wireless alarm system; CO2 inlet; infrared CO2 controller; lighting control system
Performance Features
  • Long-duration running design uses imported compressors that automatically alternate to support continuous chamber operation. This supports dependable low-temperature performance and long-duration running stability.
  • Programmable control can set temperature, humidity, light intensity and time independently in multi-step processes. This helps improve environmental tracking for incubation, cultivation and stability-study workflows.
  • LED lighting is available in multiple chamber layouts, from top-mounted lighting to three-side or partition-style designs. This supports plant-growth or climate-chamber work that depends on repeatable illumination conditions.
  • Wireless alarm and fault-display functions help operators respond quickly when abnormal conditions appear. This helps protect samples and alert operators when abnormal conditions appear.
  • Optional CO2 inlet and infrared CO2 controller support specialized plant-growth workflows. This helps operators review setpoints, trends and alarms more efficiently during routine operation.
  • RS485 or 232 communication, USB export and printer options help create operation records and trend review. This supports more reliable day-to-day laboratory use in plant growth, tissue culture, seed germination, insect culture, BOD work and climate-controlled biological cultivation.
APPLICATION SCOPE: Suitable for plant growth, tissue culture, seed germination, insect culture, BOD work and climate-controlled biological cultivation in universities, research institutes, pharmaceutical quality-control laboratories, agricultural research programs and industrial test environments that require controlled chamber operation.
HANDLING: Confirm installation space against 1570 x 1475 x 2050 mm, prepare the stated power supply, and keep air inlets, exhaust paths, shelves, ports, doors and control interfaces accessible for cleaning and maintenance. Every unit is shipped with reinforced packaging to reduce movement and impact during transport; keep the packed chamber upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select the required controller, lighting, humidity, communication and optional accessory configuration before ordering. Any displayed amount refers to the chamber body only and does not include freight. Freight is quoted separately and should be confirmed with shipping details.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This document defines installation, electrical, handling and configuration limits for the AF-M2B1500 incubator. These constraints must be satisfied to maintain safe and stable long-duration chamber operation.

  • Installation Space and Environment: Install the chamber in a +5 to 30 C working environment with clearance for the external dimensions of 1570 x 1475 x 2050 mm.
  • Electrical Supply: Connect the unit only to an AC 220 V 50 Hz supply capable of supporting the stated power input of 4300 W.
  • Transport and Handling: Keep the packed chamber upright and use suitable lifting equipment to reduce movement and impact during transport.
  • Accessibility for Maintenance: Keep air inlets, exhaust paths, shelves, ports, doors and control interfaces accessible for cleaning and maintenance.
  • Configuration Selection: Select the required controller, lighting, humidity, communication and optional accessory configuration before ordering.

Confirm the installation site meets the chamber's spatial, environmental and electrical requirements before unpacking. Position the chamber upright, connect power, and program the controller before starting operation.

Required Equipment: suitable lifting equipment, AC 220 V 50 Hz power supply, programmable controller

  1. Confirm installation site
    Confirm the installation space accommodates the external dimensions of 1570 x 1475 x 2050 mm and a working environment of +5 to 30 C.
  2. Prepare power supply
    Prepare a dedicated AC 220 V 50 Hz power supply rated for the stated power input of 4300 W.
  3. Position chamber upright
    Position the packed chamber upright using suitable lifting equipment before removing reinforced packaging.
  4. Verify access for maintenance
    Verify air inlets, exhaust paths, shelves, ports, doors and control interfaces remain accessible for cleaning and maintenance.
  5. Configure program parameters
    Set the programmable controller's multi-segment temperature, humidity, light intensity and time parameters according to the cultivation protocol.
  6. Start long-duration operation
    Start the long-duration operation cycle and monitor alarm or fault displays for abnormal conditions.

How does the alternating compressor design in the 1500 L programmable LED light incubator support long-duration stability?

The unit uses two imported compressors with an alternating long-duration operation design that automatically switches between compressors to distribute wear and extend operational life. This design supports dependable low-temperature performance and continuous running stability for cultivation programs lasting weeks or months, as stated in the product specifications.

What data logging and external communication options are available for the AF-M2B1500 incubator?

The incubator supports optional RS485 or RS232 communication interface and software, an embedded printer, USB data storage, and a wireless alarm system. These options enable operation records, trend review, and remote monitoring for integration into laboratory data workflows.

What installation space and power infrastructure are required for the 1500 L LED light incubator?

The incubator has external dimensions of 1570 x 1475 x 2050 mm and requires a 4300 W power supply at AC 220 V, 50 Hz. The working environment must be +5 to 30°C. Installation planning should ensure adequate clearance for air inlets, exhaust paths, and access to shelves, ports, doors, and control interfaces.

The 1500 L Programmable LED Light Incubator (SKU AF-LE-E-M2LP-1500-B150) uses dual imported compressors with alternating operation for continuous long-duration cultivation, a programmable multi-segment controller for temperature, humidity, light, and time, and a 0–55000 lx six-step LED lighting system. However, the base configuration lacks active humidity control, and the 4300 W power draw plus large footprint (1570 x 1475 x 2050 mm) require careful installation planning.

Positive

  • Dual alternating compressors for long-duration running: Two imported compressors automatically alternate to support continuous chamber operation, ensuring stable low-temperature performance and reliable running over weeks or months.
  • Multi-segment programmable controller: Up to 30 program segments with independent temperature, humidity, light intensity, and time settings enable precise environmental tracking for complex incubation, cultivation, or stability-study workflows.

Trade-offs

  • No active humidity control in base configuration: The product specification states no active humidity control for this configuration; passive humidity deviation of ±5% to 7% RH applies, which may limit applications requiring tight humidity regulation.
  • High power draw and large footprint: The 4300 W power requirement and external dimensions of 1570 x 1475 x 2050 mm demand dedicated electrical infrastructure and adequate installation space; working environment must be +5 to 30 °C.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).