Product Overview

LED Plant Growth Chamber, 490 L is a LED plant growth chamber designed for plant growth, seed germination, tissue culture, crop seedling studies, algae growth and laboratory climate simulation. This configuration offers 490 l working volume, Without light: 5 to 45 C; with single-layer light: 10 to 45 C; with double-layer light: 15 to 45 C, dual-chamber led cultivation lighting lighting, sus304 stainless-steel chamber interior and 7-inch color touchscreen programmable controller for controlled laboratory operation.

The family uses a foamed cabinet structure, adjustable shelf support, modular LED lighting and a circulation-air design intended to keep each layer within a stable control band. The chamber uses dual imported compressors with long-duration operation design together with imported temperature-humidity sensor for H-series configurations, 1 x 2 dual-chamber light decks, helping the unit fit continuous cultivation, incubation, climate simulation or stability workflows where repeatable environmental control matters.

The series is presented for natural-environment simulation and long-duration cultivation, with optional CO2 and data functions available where the workflow requires expanded control. Installation planning can be based on the external size of 820 x 910 x 1810 mm with power requirement 2800 W. Optional functions such as rs485 or 232 communication interface and software; embedded printer; usb data storage; wireless alarm system; co2 inlet; infrared co2 controller; light-intensity automatic control; app control; multi-level user permissions allow the chamber to be configured for data logging, alarm notification, atmosphere support and application-specific monitoring.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-PGC0490
Capacity 490 L
Temperature Control Range Without light: 5 to 45 C; with single-layer light: 10 to 45 C; with double-layer light: 15 to 45 C
Temperature Resolution 0.1 C
Temperature Fluctuation / Uniformity +/- 0.5 C
Humidity Function No active humidity control stated for this configuration
Humidity Deviation +/- 3%RH at 80%RH
Lighting Configuration dual-chamber LED cultivation lighting; two independent chambers with layered lighting; standard tricolor LED spectrum; optional full-spectrum, four-color and high-intensity monochromatic modules
Controller 7-inch color touchscreen programmable controller
Chamber Material SUS304 stainless-steel chamber interior
Power / Input 2800 W
Power Supply AC 220 V, 50 Hz
Working Environment 0 to 35 C
Sensor Configuration imported temperature-humidity sensor for H-series configurations
Cooling System dual imported compressors with long-duration operation design
Internal Dimensions 700 x 610 x 500 mm
External Dimensions 820 x 910 x 1810 mm
Shelves / Light Decks 1 x 2 dual-chamber light decks
Program Function multi-segment programming for temperature, humidity, lighting intensity and time
Configuration Note Dual-chamber plant-growth chamber design
Optional Accessories and Functions RS485 or 232 communication interface and software; embedded printer; USB data storage; wireless alarm system; CO2 inlet; infrared CO2 controller; light-intensity automatic control; App control; multi-level user permissions
Performance Features
  • Programmable temperature, humidity, lighting and time control supports segmented cultivation cycles. This helps improve environmental tracking for incubation, cultivation and stability-study workflows.
  • SUS304 chamber construction and adjustable shelf supports help keep the interior easy to clean and configure. This supports more reliable day-to-day laboratory use in plant growth, seed germination, tissue culture, crop seedling studies, algae growth and laboratory climate simulation.
  • LED lighting options include tricolor standard modules plus optional full-spectrum and high-intensity solutions. This supports plant-growth or climate-chamber work that depends on repeatable illumination conditions.
  • Long-duration running design uses imported compressors and energy-saving cooling control. This supports dependable low-temperature performance and long-duration running stability.
  • Optional CO2 monitoring, wireless alarm and App features expand the chamber for advanced plant research workflows. This helps protect samples and alert operators when abnormal conditions appear.
  • User-account management, data storage and communication options support traceable operation. This supports more reliable day-to-day laboratory use in plant growth, seed germination, tissue culture, crop seedling studies, algae growth and laboratory climate simulation.
APPLICATION SCOPE: Suitable for plant growth, seed germination, tissue culture, crop seedling studies, algae growth and laboratory climate simulation in universities, research institutes, pharmaceutical quality-control laboratories, agricultural research programs and industrial test environments that require controlled chamber operation.
HANDLING: Confirm installation space against 820 x 910 x 1810 mm, prepare the stated power supply, and keep air inlets, exhaust paths, shelves, ports, doors and control interfaces accessible for cleaning and maintenance. Every unit is shipped with reinforced packaging to reduce movement and impact during transport; keep the packed chamber upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select the required controller, lighting, humidity, communication and optional accessory configuration before ordering. Any displayed amount refers to the chamber body only and does not include freight. Freight is quoted separately and should be confirmed with shipping details.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

Operate the chamber within 0 to 35 °C ambient temperature and connect to AC 220 V, 50 Hz with 2800 W capacity. Ensure air inlets and exhaust paths remain unobstructed during operation and maintain upright orientation during transport and installation.

  • Electrical Hazard Mitigation: Connect the chamber to a dedicated circuit and do not operate with damaged power cables or in wet environments.
  • Ventilation Clearance: Keep air inlets and exhaust paths free from obstructions to ensure proper cooling and compressor operation.
  • Transport Orientation: Transport the chamber only in an upright position using suitable lifting equipment to prevent compressor damage.
  • Ambient Temperature Range: Operate the chamber only in ambient temperatures between 0 and 35 °C to maintain reliable performance.

Install the chamber in a location with 0–35 °C ambient temperature and adequate ventilation. Connect to a dedicated AC 220 V, 50 Hz power supply rated for 2800 W and maintain upright orientation throughout transport and setup.

Required Equipment: Lifting equipment (e.g., forklift or pallet jack), Power supply cable (included), Shelf support brackets (included), 7-inch touchscreen controller (integrated)

  1. Inspect for transit damage
    Inspect the chamber for any transit damage, including the exterior, doors, and control panel, before installation.
  2. Position chamber upright
    Position the chamber upright in the final location using a forklift or pallet jack, ensuring a level surface and adequate clearance around all sides.
  3. Connect power supply
    Connect the power cable to a dedicated AC 220 V, 50 Hz electrical outlet capable of supplying 2800 W continuously.
  4. Set environmental parameters
    Set the desired environmental parameters using the programmable touchscreen controller, including temperature, lighting schedule, and multi-segment program if required.

How does the LED lighting configuration affect the temperature control range in the 490 L plant growth chamber?

The temperature control range depends on the lighting load. Without light, the range is 5 to 45°C. With single-layer light, it narrows to 10 to 45°C, and with double-layer light, it further narrows to 15 to 45°C. This means the achievable low-temperature limit is reduced when both LED decks are active, a key consideration for cold-stage cultivation or germination protocols.

Can the 490 L LED plant growth chamber be integrated with CO2 monitoring for closed-loop atmosphere control?

Yes, the chamber supports optional CO2 inlet and an infrared CO2 controller for closed-loop atmosphere regulation. When combined with the wireless alarm system and app control, this allows automated CO2 supplementation and remote alerting, which is critical for photosynthesis studies or high-yield tissue culture where CO2 levels must be maintained within a narrow band.

What are the installation infrastructure requirements for the AF-PGC0490 plant growth chamber?

The chamber requires a dedicated AC 220 V, 50 Hz power supply rated at 2800 W and a footprint of 820 x 910 x 1810 mm. Installation space must allow clear air inlets and exhaust paths, and the unit should be kept upright with suitable lifting equipment due to its reinforced packaging. Confirm these dimensions and power capacity before ordering to avoid site-fit issues.

The LED Plant Growth Chamber, 490 L features dual-chamber LED lighting with programmable control and SUS304 stainless steel interior, but its temperature range is constrained by lighting load (minimum 15°C with double-layer light) and lacks active humidity control, making it suitable for general plant growth and climate simulation where precise humidity regulation is not required.

Positive

  • Dual independent chambers with programmable LED lighting: The dual-chamber LED cultivation lighting with multi-segment programming supports segmented cultivation cycles, improving environmental tracking for incubation, cultivation, and stability-study workflows.
  • SUS304 stainless steel interior with adjustable shelving: The SUS304 chamber construction and adjustable shelf supports facilitate easy cleaning and flexible configuration, enabling reliable use in plant growth, seed germination, tissue culture, and algae growth applications.

Trade-offs

  • Temperature range constrained by lighting load: The temperature control range shifts upward with active lighting: without light 5-45°C, with single-layer light 10-45°C, with double-layer light 15-45°C. This limits low-temperature experiments when high-intensity lighting is required.
  • No active humidity control in this configuration: The chamber does not include active humidity control; only a humidity sensor is referenced for H-series configurations. Humidity deviation is ±3%RH at 80%RH, but without active regulation, applications requiring precise humidity setpoints are constrained.