- Thermal Service Limit: Keep the operating temperature at or below 300°C to comply with the manufacturer's recommended service limit.
- Media and Operating Review: Review media compatibility, operating pressure, temperature, target flow, and dimensional tolerance before installation.
- Surface Protection: Protect the porous surface from crushing and contamination during handling, installation, and storage.
- Cleaning Selection: Select backflushing, steam, ultrasonic, or chemical cleaning according to the process medium and operating procedure.
This procedure covers handling, compatibility review, and cleaning selection for the sintered porous titanium foam sheet. Use these steps when preparing the sheet for installation or after process exposure.
- Inspect the sheet
Inspect the porous sheet for crushing or contamination before installation. - Confirm service limits
Confirm that operating pressure, temperature, target flow, and media compatibility are within the sheet's stated limits. - Protect the porous surface
Protect the porous surface from crushing and contamination during storage, handling, and assembly. - Choose the cleaning method
Choose a cleaning method according to the process medium and operating procedure.
How does the 110 PPI pore density relate to the 50 µm filtration rating in terms of flow resistance and particle retention?
The 110 PPI describes the cellular structure with a cell spacing of approximately 0.23 mm, while the 50 µm value specifies the filtration precision. These are independent parameters that must be reviewed together when matching the sheet to an assembly. The 35–45% porosity and interconnected pathways provide a relative air permeability of 1 × 10⁻³ L/(cm²·min·Pa), balancing flow resistance with the specified filtration rating.
What are the maximum service temperature and media compatibility constraints for this sintered titanium foam sheet?
The recommended service temperature is ≤300°C. The titanium-based porous structure provides corrosion resistance and thermal stability in compatible media, but specific media compatibility, operating pressure, and temperature must be reviewed before quotation or installation. The material is titanium or titanium alloy, which offers general corrosion resistance, but aggressive chemicals or high-temperature environments may require validation.
What cleaning and handling protocols are recommended to maintain the integrity of the 50 µm porous titanium sheet?
The porous surface must be protected from crushing and contamination. Acceptable cleaning methods include backflushing, steam, ultrasonic, and compatible chemical procedures, chosen according to the process medium and operating procedure. The metallic construction supports cutting, welding, and basic machining for assembly integration, but care must be taken to avoid deforming the porous network.
This 50 µm, 110 PPI sintered titanium foam sheet (100 × 200 × 3 mm) offers a 35–45% interconnected porous network with an estimated bulk density of 2.48–2.93 g/cm³, balancing filtration precision with structural integrity for laboratory and engineered filtration assemblies. Its metallic construction supports corrosion resistance, thermal stability up to 300°C, and cleanability via backflushing, steam, ultrasonic, or chemical methods, though media compatibility and operating parameters must be verified before installation.
Positive
- Interconnected porous structure: The 35–45% porosity with approximately 0.23 mm cell spacing provides interconnected flow paths, enabling low flow resistance and stable separation for solid-liquid, gas-solid, and gas-liquid applications.
- Metallic cleanability and reuse: The titanium-based construction supports backflushing, steam, ultrasonic, and compatible chemical cleaning, allowing repeated use in compatible process conditions without structural degradation.
Trade-offs
- Temperature and media constraints: Recommended service temperature is limited to ≤300°C, and media compatibility must be verified for corrosion resistance, restricting use in higher-temperature or chemically aggressive environments.
- Handling and contamination sensitivity: The porous surface is vulnerable to crushing and contamination, requiring careful handling and cleaning procedures to maintain filtration accuracy and structural integrity.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).