Moistureproof Nitrogen ESD Cabinet 1435 L ATOMFAIR®

$2,820.00

Heavy Item Pricing: Prices for this heavy item are net prices (ex-factory / ex-warehouse) and exclude logistics or shipping fees.

Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

1435 L anti-static moistureproof nitrogen cabinet with 1%-60% RH control, 1200 × 700 × 1860 mm body, 5 shelves, three doors and ESD storage. Order now.

SKU: AF-EI-E-MNIC-ESD0-14L3
Category:
Brands:

1435L-6 Moistureproof Nitrogen Integrated Cabinet, Anti-Static Cabinet Body

Research-grade laboratory product

Product Overview

The 1435 L configuration uses a anti-static cabinet body, a humidity control range of 1%-60% RH, outer dimensions of 1200 × 700 × 1860 mm, inner dimensions of 1155 × 650 × 1680 mm and 5 adjustable shelves. The 1435 L layout uses a three-door cabinet.

This moistureproof nitrogen integrated cabinet combines electronic dehumidification with nitrogen control in one storage platform for efficient low-humidity recovery. It helps reduce moisture absorption, oxidation, optical haze, solderability loss and storage instability while lowering gas demand compared with ordinary nitrogen-only cabinet operation.

Typical application areas include research laboratories, electronics workshops, optical storage rooms, incoming-material control areas, powder and film storage spaces and quality-control environments that require low-humidity cabinet protection with efficient nitrogen management. This body type is suitable for electrostatic-control areas and ESD-sensitive material handling.

The cabinet combines 1.2 mm galvanized steel cabinet with anti-static exterior coating, tempered-glass viewing doors and magnetic sealing, an electronic dehumidification core with regenerative absorbent polymer, a precision nitrogen-control device, fully automatic switching between system modes and display-based cabinet management for dependable daily operation.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-MNIC1435F-6
Product Family Moistureproof Nitrogen Integrated Cabinet
Cabinet Body Anti-static cabinet body
Nominal Capacity 1435 L
Humidity Control Range 1%-60% RH
Outer Dimensions (W × D × H) 1200 × 700 × 1860 mm
Inner Dimensions (W × D × H) 1155 × 650 × 1680 mm
Adjustable Shelf Quantity 5
Door Configuration Three-door cabinet
Cabinet Material 1.2 mm galvanized steel cabinet with anti-static exterior coating and 5 mm tempered-glass viewing doors
Control Mode Fully automatic switching between dehumidification and nitrogen-control modes
Dehumidification System Electronic dehumidification core with regenerative absorbent polymer
Dehumidification Module Housing ABS plus flame-retardant housing
Nitrogen Control System Precision nitrogen-control device for rapid cabinet humidity reduction
Integrated Efficiency Designed to reduce nitrogen usage by more than 50% compared with ordinary nitrogen cabinets
Suitable Stored Materials Moisture-sensitive electronic parts, optical components, powders, films and laboratory materials

Key Features and Advantages

  • Integrated dual-system architecture combining an electronic dehumidification core with a precision nitrogen-control device.
  • High-performance absorbent polymer and regenerative dehumidification design for repeat-use moisture control.
  • ABS plus flame-retardant housing on the dehumidification module for durable routine cabinet operation.
  • Fully automatic switching logic between dehumidification and nitrogen-control modes according to cabinet humidity conditions.
  • Integrated cabinet design intended to reduce nitrogen usage by more than 50% compared with ordinary nitrogen cabinets.

Optional Items and Consultation

  • Internal high-brightness LED lighting for improved visibility in cabinet interiors.
  • Stainless steel cabinet-body upgrade for cleaner or more corrosion-conscious storage environments.
  • Nitrogen generator configuration for applications that prefer an on-site nitrogen supply.
  • RS485 communication interface for PC-side monitoring and recorded cabinet-status management.
  • Over-humidity alarm device that triggers when measured humidity exceeds the configured set value.
  • If optional items are required, please contact inquiry@atomfair.com.
APPLICATION SCOPE: Suitable for research laboratories, electronics workshops, incoming-material control areas, powder and film storage rooms and quality-control environments that require low-humidity cabinet protection with efficient nitrogen management.
HANDLING & STORAGE: Install the cabinet on a stable indoor surface, keep the door closed during normal use, distribute stored items evenly across the 5 shelf levels, protect structural and sealing components during movement, and use reinforced wooden-crate packaging when shipment protection is required. Verify stable gas-supply conditions before operation.
IMPORTANT NOTICE: Confirm the correct model, cabinet body type, capacity and optional accessories before ordering. Inspect the cabinet after delivery, verify level installation and door sealing, and do not exceed the stated shelf-loading or application conditions. Confirm utility conditions such as power and gas connections before formal use.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The cabinet requires stable indoor installation on a level surface with proper door sealing. All stored items must be distributed evenly, and gas supply conditions must be verified before operation.

  • Installation Requirements: Install the cabinet on a stable indoor surface and ensure level positioning.
  • Sealing Integrity: Keep the door closed during normal use to maintain humidity control.
  • Load Distribution: Distribute stored items evenly across the 5 shelf levels to avoid exceeding loading limits.
  • Gas Supply Verification: Verify stable gas-supply conditions before operation to ensure proper nitrogen control.
  • Post-Delivery Inspection: Inspect the cabinet after delivery and verify level installation and door sealing.

Setup involves inspecting the cabinet, installing it on a stable level surface, and verifying utility connections. Operation requires even load distribution and keeping the door closed to maintain humidity control.

  1. Inspect the cabinet
    Inspect the cabinet after delivery for any damage.
  2. Install the cabinet
    Install the cabinet on a stable indoor surface.
  3. Verify level and sealing
    Verify level installation and door sealing.
  4. Confirm utility connections
    Confirm utility conditions such as power and gas connections before formal use.
  5. Verify gas supply
    Verify stable gas-supply conditions before operation.
  6. Distribute stored items
    Distribute stored items evenly across the 5 shelf levels.
  7. Maintain door closure
    Keep the door closed during normal use to maintain humidity control.

How does the integrated electronic dehumidification and nitrogen control system reduce overall nitrogen consumption?

The cabinet's dual-system architecture combines an electronic dehumidification core with a precision nitrogen-control device, enabling fully automatic switching between modes based on humidity conditions. This design reduces nitrogen usage by more than 50% compared with ordinary nitrogen-only cabinets while maintaining efficient low-humidity recovery, as stated in the product specifications.

What materials or environments are incompatible with the anti-static cabinet body and its storage conditions?

The cabinet is explicitly rated for moisture-sensitive electronic parts, optical components, powders, films, and laboratory materials within electrostatic-control areas. It is not specified for explosive, flammable, or chemically aggressive substances, and the cabinet should not be used beyond its stated application scope or shelf-loading conditions.

What installation and utility preparations are required before the cabinet can achieve its specified 1%–60% RH humidity control range?

The cabinet must be installed on a stable indoor surface, leveled, and checked for door sealing. Stored items should be evenly distributed across the five adjustable shelves. Stable gas-supply conditions and power connections must be verified before operation, as indicated in the handling instructions.

The 1435L-6 Moistureproof Nitrogen Integrated Cabinet with anti-static body combines electronic dehumidification and precision nitrogen control for efficient low-humidity storage, reducing nitrogen consumption by over 50% while supporting ESD-sensitive materials. However, it requires stable installation and external nitrogen supply, which laboratories must account for.

Positive

  • Integrated dual-system reduces nitrogen consumption: Combines electronic dehumidification with nitrogen control, reducing nitrogen usage by more than 50% compared to ordinary nitrogen-only cabinets, lowering operational gas costs.
  • Anti-static cabinet for ESD-safe storage: Anti-static coating and cabinet body provide electrostatic discharge protection, suitable for storing moisture-sensitive and ESD-sensitive electronic components, powders, and films.

Trade-offs

  • Requires stable installation and leveling: The cabinet must be installed on a stable indoor surface, properly leveled, and door sealing verified to maintain humidity control performance and structural integrity.
  • Dependent on external nitrogen supply: Operation requires a stable gas supply; an optional nitrogen generator can be added but is not included, adding infrastructure dependency for laboratories without existing nitrogen lines.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).