Dual-Flow Nitrogen Cabinet 1435 L Anti-Static ATOMFAIR®

$2,600.00

Heavy Item Pricing: Prices for this heavy item are net prices (ex-factory / ex-warehouse) and exclude logistics or shipping fees.

Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

1435 L dual-flow nitrogen cabinet with anti-static body, 1%-60% RH control, 1200 × 700 × 1860 mm lab size, two doors, and 5 shelves. Order now.

SKU: AF-EI-E-DFNC-ESD0-14L2
Category:
Brands:

1435L-4 Dual-Flow Energy-Saving Nitrogen Cabinet, Anti-Static Cabinet Body

Research-grade laboratory product

Product Overview

The 1435 L configuration uses a anti-static cabinet body, a humidity control range of 1%-60% RH, outer dimensions of 1200 × 700 × 1860 mm, inner dimensions of 1155 × 650 × 1680 mm and 5 adjustable shelves. The 1435 L layout uses a two-door cabinet.

This dual-flow energy-saving nitrogen cabinet is designed for low-humidity storage tasks where fast recovery after door opening and reduced unnecessary gas consumption are both important. It supports moisture-sensitive materials that require controlled nitrogen-assisted drying while improving atmosphere recovery and lowering routine nitrogen demand.

Typical application areas include research laboratories, electronics workshops, component staging rooms, optical storage spaces and inspection environments where cabinet doors may be opened more frequently during routine work. This body type is suitable for electrostatic-control areas and ESD-sensitive material handling.

The cabinet combines 1.2 mm galvanized steel cabinet with anti-static exterior coating, tempered-glass viewing doors and magnetic sealing, dual-flow nitrogen management, automatic switching between large-flow and small-flow operation, tempered-glass viewing areas and perforated adjustable shelves for stable day-to-day cabinet performance.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-DFNC1435F-4
Product Family Dual-Flow Energy-Saving Nitrogen Cabinet
Cabinet Body Anti-static cabinet body
Nominal Capacity 1435 L
Humidity Control Range 1%-60% RH
Outer Dimensions (W × D × H) 1200 × 700 × 1860 mm
Inner Dimensions (W × D × H) 1155 × 650 × 1680 mm
Adjustable Shelf Quantity 5
Door Configuration Two-door cabinet
Cabinet Material 1.2 mm galvanized steel cabinet with anti-static exterior coating and 5 mm tempered-glass viewing doors
Control Mode Automatic software-controlled nitrogen management
Large-Flow Meter Setting 15-50 L/min
Small-Flow Meter Setting 1-5 L/min
Switching Logic Automatic switching between large-flow and small-flow operation
Operating Characteristic Fast recovery after door opening with reduced unnecessary nitrogen use
Suitable Stored Materials Moisture-sensitive electronic parts, optical components and frequently accessed laboratory materials

Key Features and Advantages

  • Dual-flow nitrogen control with large-flow settings of 15-50 L/min and small-flow settings of 1-5 L/min.
  • Automatic switching between high-flow and low-flow operation without manual intervention.
  • Fast recovery after door opening helps restore the cabinet atmosphere while reducing unnecessary nitrogen consumption.
  • Sealed galvanized steel cabinet structure with tempered-glass viewing areas for controlled dry storage.
  • Perforated adjustable shelves support airflow circulation and flexible material arrangement.

Optional Items and Consultation

  • Internal high-brightness LED lighting for improved visibility in cabinet interiors.
  • Stainless steel cabinet-body upgrade for cleaner or more corrosion-conscious storage environments.
  • Electronic dehumidification module that can operate together with the gas-filling unit to reduce nitrogen use.
  • Nitrogen generator configuration for applications that prefer an on-site nitrogen supply.
  • RS485 communication interface for PC-side monitoring and recorded cabinet-status management.
  • Over-humidity alarm device that triggers when measured humidity exceeds the configured set value.
  • If optional items are required, please contact inquiry@atomfair.com.
APPLICATION SCOPE: Suitable for research laboratories, electronics workshops, component staging rooms, optical storage spaces and inspection environments that require low-humidity nitrogen-assisted storage with rapid recovery after cabinet access.
HANDLING & STORAGE: Install the cabinet on a stable indoor surface, keep the door closed during normal use, distribute stored items evenly across the 5 shelf levels, protect structural and sealing components during movement, and use reinforced wooden-crate packaging when shipment protection is required. Verify stable gas-supply conditions before operation.
IMPORTANT NOTICE: Confirm the correct model, cabinet body type, capacity and optional accessories before ordering. Inspect the cabinet after delivery, verify level installation and door sealing, and do not exceed the stated shelf-loading or application conditions. Confirm utility conditions such as power and gas connections before formal use.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The cabinet requires a stable indoor surface and a continuous nitrogen supply to maintain the 1%-60% RH range. Door seals and anti-static coating must remain intact to prevent moisture ingress and electrostatic discharge.

  • Installation Environment: Place the cabinet on a level, vibration-free surface away from direct sunlight and heat sources.
  • Gas Supply Requirements: Verify a stable nitrogen source with pressure and flow suitable for the large-flow (15-50 L/min) and small-flow (1-5 L/min) settings.
  • Loading Constraints: Distribute stored items evenly across the five adjustable shelves to avoid overloading and maintain airflow.
  • Door Operation: Keep the cabinet door closed during normal operation and minimize open duration to preserve low-humidity atmosphere.
  • Component Protection: Protect the tempered-glass viewing doors, magnetic seals, and anti-static coating from impact or abrasive contact during movement.

Position the cabinet on a stable indoor surface and connect a regulated nitrogen supply. Configure the automatic dual-flow control to maintain the desired humidity range for moisture-sensitive materials.

Required Equipment: Regulated nitrogen supply line, Leveling feet adjustment tool, Humidity calibration device

  1. Install the Cabinet
    Place the cabinet on a level indoor surface and adjust the leveling feet so the unit is stable and the door seals evenly.
  2. Connect Nitrogen Supply
    Attach the nitrogen line to the cabinet inlet, set the large-flow meter to 15-50 L/min and the small-flow meter to 1-5 L/min, then verify the gas supply is stable.
  3. Set Humidity Control Range
    Configure the software-controlled humidity target between 1% and 60% RH using the cabinet's control interface.
  4. Load Materials
    Distribute moisture-sensitive items evenly across the adjustable shelves, ensuring no blockage of the perforated airflow paths.
  5. Close Door and Allow Recovery
    Close the door fully and allow the automatic dual-flow system to restore the low-humidity atmosphere before next access.
  6. Monitor Humidity Levels
    Periodically check the displayed humidity reading and confirm the cabinet remains within the set range during extended storage.

How does the dual-flow nitrogen management system balance recovery speed and nitrogen consumption in the 1435L-4 cabinet?

The dual-flow system automatically switches between large-flow (15-50 L/min) for rapid atmosphere recovery after door opening and small-flow (1-5 L/min) for steady-state maintenance, reducing unnecessary nitrogen use while restoring low-humidity conditions quickly. This controlled switching logic is built into the cabinet's automatic software-based nitrogen management.

What anti-static features does the 1435L-4 cabinet provide for ESD-sensitive component storage?

The cabinet body is constructed from 1.2 mm galvanized steel with an anti-static exterior coating, making it suitable for electrostatic-control areas and ESD-sensitive material handling. The design includes tempered-glass viewing doors and magnetic sealing to maintain a controlled, low-humidity environment compatible with moisture-sensitive electronic parts and optical components.

What are the infrastructure requirements for installing the 1435L-4 dual-flow nitrogen cabinet?

The cabinet requires a stable indoor surface, even distribution of stored items across its 5 adjustable shelves, and a stable gas-supply connection capable of supporting the large-flow meter setting of 15-50 L/min and small-flow setting of 1-5 L/min. Before operation, verify stable gas-supply conditions, power connections, and door sealing to ensure proper low-humidity nitrogen-assisted storage.

The 1435L-4 dual-flow nitrogen cabinet provides 1435 L capacity with anti-static construction, automatic flow switching between 15-50 L/min and 1-5 L/min for rapid recovery and reduced nitrogen consumption, suitable for moisture-sensitive materials in ESD-controlled environments.

Positive

  • Dual-flow automatic nitrogen switching: Automatically transitions between large-flow (15-50 L/min) and small-flow (1-5 L/min) operation, enabling fast recovery after door openings while minimizing unnecessary nitrogen consumption.
  • Anti-static ESD-safe construction: 1.2 mm galvanized steel cabinet with anti-static exterior coating and tempered-glass viewing doors provides electrostatic protection for sensitive electronic and optical components.

Trade-offs

  • Requires external nitrogen supply: Cabinet depends on a stable external nitrogen source and gas-supply infrastructure; operation is not possible without a continuous nitrogen feed, adding installation complexity.
  • Installation and sealing verification needed: Level installation and door sealing must be verified after delivery to maintain humidity control; the large cabinet dimensions (1200×700×1860 mm) demand adequate floor space and careful handling.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).