1435L-6 Anti-Oxidation Nitrogen CabinetResearch-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
This nitrogen cabinet requires a stable indoor surface, verified gas-supply conditions, and electrical power for automatic control. Door sealing must be intact and shelves evenly loaded to maintain the controlled low-humidity atmosphere.
- Gas Supply Constraint: Connect the cabinet to a regulated nitrogen source with flow adjustable between 0 and 50 L/min before operation.
- Installation Surface Constraint: Install the cabinet on a level, stable indoor surface to maintain door magnet seal integrity and sensor accuracy.
- Load Distribution Constraint: Distribute stored materials evenly across the five adjustable shelves without exceeding the stated shelf-loading limits.
- Sensor Accuracy Constraint: Monitor humidity indication accuracy within ±3% RH and account for the annual sensor drift of 0.3% during long-term storage.
- Alarm Configuration Constraint: Configure the over-humidity alarm to trigger when measured humidity exceeds the user-set threshold to protect stored materials.
Install the cabinet on a level surface and connect both the nitrogen supply and power before operation. Distribute stored materials evenly and maintain door closure to preserve the controlled atmosphere.
Required Equipment: Regulated nitrogen supply with flow control, Electrical power outlet (as specified), Leveling tool for cabinet feet adjustment
- Inspect and level cabinet
Inspect the cabinet upon delivery for structural integrity and door sealing, then level it on the installation surface using the adjustable feet. - Connect utilities
Connect the nitrogen supply to the cabinet inlet and plug the power cord into a suitable electrical outlet. - Set humidity and flow
Set the desired humidity level within the 1% to 60% RH range using the automatic computer control and adjust the nitrogen flow between 0 and 50 L/min to maintain the set point. - Load materials evenly
Distribute oxidation-sensitive materials evenly across the five adjustable shelves without blocking the internal air circulation. - Close and monitor
Close the tempered-glass door securely to seal the cabinet and verify the temperature and humidity display remain within the configured range. - Configure alarm if needed
Set the over-humidity alarm threshold to the desired value to trigger a notification if humidity exceeds the limit.
How does the ±3% RH humidity indication accuracy and 0.3% annual sensor drift affect the 1435L-6 Anti-Oxidation Nitrogen Cabinet's ability to maintain a consistent low-humidity environment for oxidation-sensitive materials?
The Honeywell temperature and humidity sensor provides ±3% RH indication accuracy with 0.3% annual drift, ensuring reliable long-term monitoring. The cabinet's humidity control range is 1%-60% RH, so users can set a target within this range, but actual humidity may vary by up to ±3% RH, which is acceptable for most oxidation-sensitive electronic components, optics, powders, and films. The automatic computer control continuously adjusts nitrogen flow (0-50 L/min) to maintain the set point within that tolerance.
Can the 1435L-6 Anti-Oxidation Nitrogen Cabinet be integrated with an external nitrogen generator or laboratory monitoring system, and what are the compatibility requirements?
Yes, the cabinet supports an optional nitrogen generator configuration for on-site nitrogen supply, and the nitrogen flow control range of 0-50 L/min defines the generator's required output capacity. Additionally, an optional RS485 communication interface enables PC-side monitoring and recorded cabinet-status management, allowing integration with laboratory information systems. The electronic dehumidification module can also be combined with the gas-filling unit to reduce nitrogen consumption.
What utility conditions and installation steps are required for the 1435L-6 Anti-Oxidation Nitrogen Cabinet to ensure proper operation and safety?
Install the cabinet on a stable indoor surface, and verify stable gas-supply conditions (nitrogen flow 0-50 L/min) and power connections before operation. Distribute stored items evenly across the 5 adjustable shelves to avoid overloading, and keep the door closed during normal use to maintain the nitrogen atmosphere. The cabinet features a lockable structure, magnetic sealing, and tempered-glass viewing doors; do not exceed stated shelf-loading or application conditions as noted in the important notice.
The 1435L-6 Anti-Oxidation Nitrogen Cabinet provides a controlled low-humidity nitrogen atmosphere for oxidation-sensitive materials, featuring Honeywell sensor accuracy (±3% RH, 0.3% annual drift) and automatic computer control with adjustable nitrogen flow, but requires an external nitrogen supply and has a minimum humidity setpoint of 1% RH, with the over-humidity alarm offered as an optional upgrade.
Positive
- Precision humidity sensing with low drift: Integrated Honeywell temperature and humidity sensor delivers ±3% RH indication accuracy and 0.3% annual drift, ensuring reliable long-term monitoring without frequent recalibration.
- Automatic control with adjustable nitrogen flow: Fully automatic computer control with 0–50 L/min nitrogen flow adjustment and display-based monitoring enables repeatable atmosphere management for daily laboratory operations.
Trade-offs
- Requires external nitrogen supply: The cabinet relies on a continuous external nitrogen source or generator; it is not a standalone dehumidification unit and cannot operate without a stable gas connection.
- Over-humidity alarm not standard: The over-humidity alarm is listed as an optional item; users requiring automated alerts for humidity excursions must order the upgrade separately, adding cost and lead time.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.