Anti-Oxidation Nitrogen Cabinet 1435 L 1%-60% RH ATOMFAIR®

$2,500.00

Heavy Item Pricing: Prices for this heavy item are net prices (ex-factory / ex-warehouse) and exclude logistics or shipping fees.

Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

1435 L anti-oxidation nitrogen cabinet with 1%-60% RH control, 0-50 L/min N2 flow, Honeywell sensing, standard white body, 5 shelves and two doors. Order now.

SKU: AF-EI-E-AONC-STD0-14L2
Category:
Brands:

1435L-4 Anti-Oxidation Nitrogen Cabinet

Research-grade laboratory product

Product Overview

The 1435 L configuration uses a standard white cabinet body, a humidity control range of 1%-60% RH, outer dimensions of 1200 × 700 × 1860 mm, inner dimensions of 1155 × 650 × 1680 mm and 5 adjustable shelves. The 1435 L layout uses a two-door cabinet.

This anti-oxidation nitrogen cabinet is designed for oxidation-sensitive and moisture-sensitive materials that benefit from a controlled low-humidity nitrogen atmosphere. It helps reduce moisture absorption, oxidation, optical haze, solderability loss and storage instability during inspection staging, daily handling and long-term preservation.

Typical application areas include research laboratories, electronics workshops, optical part storage rooms, powder and film storage areas, technical archives and quality-control spaces that require organized nitrogen-assisted dry storage. This body type suits general laboratories, inspection rooms and organized storage areas.

The cabinet combines 1.2 mm galvanized steel cabinet with white exterior panels, tempered-glass viewing doors and magnetic sealing, Honeywell temperature and humidity sensing, fully automatic computer control, temperature and humidity display, perforated adjustable shelves and 0-50 L/min nitrogen-flow adjustment for repeatable daily operation.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-AONC1435-4
Product Family Anti-Oxidation Nitrogen Cabinet
Cabinet Body Standard white cabinet body
Nominal Capacity 1435 L
Humidity Control Range 1%-60% RH
Outer Dimensions (W × D × H) 1200 × 700 × 1860 mm
Inner Dimensions (W × D × H) 1155 × 650 × 1680 mm
Adjustable Shelf Quantity 5
Door Configuration Two-door cabinet
Cabinet Material 1.2 mm galvanized steel cabinet with white exterior panels and 5 mm tempered-glass viewing doors
Control Mode Fully automatic computer control
Display and Monitoring Display-based monitoring for temperature, humidity and operating status
Temperature Display Range -9°C to 99°C
Humidity Display Range 0%-99% RH
Humidity Indication Accuracy ±3% RH
Annual Sensor Drift 0.3%
Sensor Honeywell temperature and humidity sensor
Nitrogen Flow Control 0-50 L/min
Alarm Function Over-humidity alarm support
Suitable Stored Materials Oxidation-sensitive electronic components, optical parts, powders, films and laboratory materials

Key Features and Advantages

  • 1.2 mm galvanized steel cabinet construction with 5 mm tempered-glass viewing panels, magnetic door sealing and a lockable cabinet structure.
  • Honeywell temperature and humidity sensor with ±3% RH humidity indication accuracy and 0.3% annual drift.
  • Fully automatic computer control with temperature display range of -9°C to 99°C and humidity display range of 0%-99% RH.
  • Perforated adjustable shelves support orderly material staging and internal circulation.
  • Nitrogen-control arrangement with 0-50 L/min flow adjustment for controlled cabinet-atmosphere management.

Optional Items and Consultation

  • Anti-static cabinet body upgrade with ESD-compliant exterior coating for electrostatic-control environments.
  • Internal high-brightness LED lighting for improved visibility in cabinet interiors.
  • Stainless steel cabinet-body upgrade for cleaner or more corrosion-conscious storage environments.
  • Electronic dehumidification module that can operate together with the gas-filling unit to reduce nitrogen use.
  • Nitrogen generator configuration for applications that prefer an on-site nitrogen supply.
  • RS485 communication interface for PC-side monitoring and recorded cabinet-status management.
  • Over-humidity alarm device that triggers when measured humidity exceeds the configured set value.
  • If optional items are required, please contact inquiry@atomfair.com.
APPLICATION SCOPE: Suitable for research laboratories, electronics workshops, optical storage rooms, powder and film storage areas, technical archives and quality-control environments that require controlled nitrogen-assisted dry storage for oxidation-sensitive and moisture-sensitive materials.
HANDLING & STORAGE: Install the cabinet on a stable indoor surface, keep the door closed during normal use, distribute stored items evenly across the 5 shelf levels, protect structural and sealing components during movement, and use reinforced wooden-crate packaging when shipment protection is required. Verify stable gas-supply conditions before operation.
IMPORTANT NOTICE: Confirm the correct model, cabinet body type, capacity and optional accessories before ordering. Inspect the cabinet after delivery, verify level installation and door sealing, and do not exceed the stated shelf-loading or application conditions. Confirm utility conditions such as power and gas connections before formal use.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The cabinet requires a stable indoor installation and continuous nitrogen supply to maintain controlled low-humidity conditions. Stored materials are limited to oxidation-sensitive and moisture-sensitive items that benefit from the controlled atmosphere.

  • Nitrogen supply: The cabinet needs a stable nitrogen gas source with a flow rate adjustable between 0 and 50 L/min to sustain the target humidity range.
  • Installation requirements: The cabinet must be placed on a level, stable indoor surface to ensure proper door sealing and prevent structural stress.
  • Material compatibility: Only oxidation-sensitive and moisture-sensitive materials should be stored to utilize the cabinet's anti-oxidation functionality.
  • Alarm response: An over-humidity alarm triggers when the internal humidity exceeds the set value, requiring immediate inspection and adjustment of nitrogen flow or door seal integrity.
  • Even loading: Stored items must be evenly distributed across adjustable shelves to allow proper gas circulation and avoid overloading.

This procedure outlines the initial installation, nitrogen supply connection, and material loading steps for the cabinet. Proper adherence ensures effective anti-oxidation storage and minimizes nitrogen consumption.

Required Equipment: Nitrogen supply line with adjustable flow regulator (0-50 L/min)

  1. Position and level cabinet
    Position and level the cabinet on a stable indoor surface, then confirm that the door seals completely and locks securely.
  2. Connect nitrogen supply
    Connect a nitrogen gas supply to the cabinet's inlet and set the flow regulator to an initial rate within the 0-50 L/min range.
  3. Set humidity setpoint
    Turn on the automatic computer control and set the desired humidity setpoint between 1% and 60% RH using the display interface.
  4. Purge and stabilize cabinet
    Allow the cabinet interior to purge and stabilize at the set humidity for approximately 5-10 minutes before loading materials.
  5. Distribute materials evenly
    Distribute oxidation-sensitive items evenly across the five perforated shelves to promote uniform gas circulation and prevent overloading.
  6. Monitor operation
    Keep the door closed during normal operation and monitor the temperature and humidity display for any deviations or alarms.
  7. Respond to alarms
    If an over-humidity alarm occurs, inspect the door seal and adjust the nitrogen flow rate upward until the humidity returns to the set range.

How does the nitrogen flow adjustment range (0-50 L/min) affect the achievable humidity level and operational cost of the 1435L-4 nitrogen cabinet?

The cabinet's humidity control range is 1%-60% RH; lower humidity levels typically require higher nitrogen flow rates, increasing consumption. To reduce nitrogen use, an optional electronic dehumidification module can be integrated to operate alongside the gas-filling unit, as stated in the product description.

Is the 1435L-4 nitrogen cabinet suitable for storing electrostatic discharge (ESD)-sensitive components without additional upgrades?

The standard cabinet uses a galvanized steel body with white exterior panels, which may not provide ESD protection. For electrostatic-control environments, an anti-static cabinet body upgrade with ESD-compliant exterior coating is available as an optional item, as noted in the product description.

What are the installation and operational requirements for the 1435L-4 anti-oxidation nitrogen cabinet?

The cabinet must be installed on a stable indoor surface, with the door kept closed during normal use. Stored items should be evenly distributed across the five adjustable shelves. Prior to operation, a stable gas-supply condition must be verified, and the cabinet requires a level installation and proper door sealing, as outlined in the handling and storage instructions.

The 1435L-4 Anti-Oxidation Nitrogen Cabinet provides a 1435 L controlled atmosphere storage solution with a Honeywell sensor offering ±3% RH accuracy and 0.3% annual drift, and adjustable nitrogen flow from 0-50 L/min, but requires an external nitrogen supply and stable power connection, and its large footprint (1200×700×1860 mm) demands adequate floor space and level installation.

Positive

  • Precise humidity sensing with low drift: Integrates a Honeywell temperature and humidity sensor with ±3% RH indication accuracy and 0.3% annual drift, enabling reliable long-term monitoring without frequent recalibration.
  • Adjustable nitrogen flow for atmosphere control: Nitrogen flow can be set from 0-50 L/min via a flow adjustment, allowing precise management of the cabinet atmosphere to match the sensitivity of stored materials.

Trade-offs

  • Requires external nitrogen supply and power: Operation depends on an external nitrogen gas source and electrical power connection; users must verify stable gas supply conditions and utility connections before formal use.
  • Large cabinet footprint requires adequate space: With outer dimensions of 1200×700×1860 mm, the cabinet demands a stable, level indoor surface and sufficient floor space for installation and access, which may be a constraint in smaller laboratories.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).