Description
MicroPette Plus 8-channel 30-300 µL PipetteProduct Type: Fully autoclavable manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The pipette must be fully autoclaved for sterilization and calibrated to ISO 8655-2. Compatible tips are required to maintain accuracy and prevent leakage.
- Sterilization: Full autoclaving is required to sterilize the pipette without damage to internal components.
- Calibration: Calibration must be performed according to ISO 8655-2 using the specified test volumes to ensure systematic and random error thresholds.
- Tip Compatibility: Only tips designed for the 30-300 µL range and 8-channel format should be used to avoid poor sealing and inaccurate volumes.
How does the 30-300 µL volume range and 5 µL increment affect pipetting accuracy across the three test volumes?
The pipette's accuracy is characterized by systematic and random error values that are retained per test volume (300, 150, 30 µL) in the technical table. The 5 µL increment provides fine volume adjustment within the range, but the error specifications vary by test volume, so users must consult the technical table for exact values at their working volume to assess precision trade-offs.
Can the MicroPette Plus 8-channel 30-300 µL pipette be used with standard 200 µL or 300 µL tips for microplate applications?
The product description indicates the need to confirm compatible tips before ordering, suggesting that not all tip types are automatically suitable. It is designed for microplate loading, PCR plate preparation, and ELISA workflows, so it likely requires tips that fit securely for 8-channel operation; users should verify tip compatibility with Atomfair's technical sales team.
What sterilization and calibration procedures are required for routine use of this 8-channel pipette?
The pipette is fully autoclavable, allowing sterilization of the entire instrument without disassembly. It includes an ISO 8655-2 user calibration reference in the technical table, so routine calibration should follow that standard. Adequate maintenance involves periodic calibration per the technical table and sterilization as needed for contamination control.
The MicroPette Plus 8-channel 30-300 µL Pipette is a fully autoclavable manual pipette designed for high-throughput microplate and PCR workflows, with ISO 8655-2 traceable calibration and specified systematic/random error at three test volumes (300, 150, 30 µL). Its 5 µL increment and 8-channel format enable parallel reagent transfer, but the fixed volume range and manual operation impose constraints on low-volume applications and user technique consistency.
Positive
- Fully autoclavable for sterilization: The entire pipette can be autoclaved, enabling decontamination between assays or after handling biohazardous samples without disassembly, which is critical for PCR and cell culture workflows.
- ISO 8655-2 calibration traceability: Systematic and random error values are provided at three test volumes (300, 150, 30 µL) per ISO 8655-2, allowing direct verification of accuracy and precision for method validation and routine quality control.
Trade-offs
- Fixed volume range limits flexibility: The 30-300 µL range with a 5 µL increment cannot accommodate sub-30 µL volumes or fine adjustments below 5 µL, requiring a separate pipette for lower-volume applications common in molecular biology.
- Manual operation requires consistent technique: As a manual pipette, accuracy depends on operator plunger speed, angle, and tip immersion depth, introducing variability that automated systems avoid; training is needed for reproducible results across users.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).